{"product_id":"bently-nevada-146031-01-3500-22m-10base-t-100base-tx-i-o-module","title":"Bently Nevada 146031-01 3500\/22M 10Base-T\/100Base-TX I\/O Module","description":"\u003ch3\u003eDescription\u003c\/h3\u003e\n\u003cp\u003eThe Bently Nevada \u003cstrong\u003e146031-01\u003c\/strong\u003e is a 10Base-T\/100Base-TX I\/O module designed for interfacing the 3500\/22M Transient Data Interface (TDI) module to host software via Ethernet in machinery protection and condition monitoring systems. It resides in a full-height rear slot of a 3500 rack and incorporates an RJ-45 copper Ethernet interface conforming to IEEE 802.3 standards to support BN Host Protocol and BN TDI Protocol over TCP\/IP. The module provides external physical interfaces for system contacts including Trip Multiply, Alarm Inhibit, and Rack Reset inputs, as well as an onboard OK Relay and a 2-pin Signal Common external grounding terminal.\u003c\/p\u003e\n\u003ch3\u003eFeatures\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eIntegrates an autosensing 10Base-T\/100Base-TX copper Ethernet RJ-45 connection.\u003c\/li\u003e\n\u003cli\u003eFeatures an onboard OK Relay for rack status annunciation.\u003c\/li\u003e\n\u003cli\u003eProvides system contact input terminals for Trip Multiply, Alarm Inhibit, and Rack Reset.\u003c\/li\u003e\n\u003cli\u003eIncludes a 2-pin Signal Common terminal for connecting instrument ground.\u003c\/li\u003e\n\u003cli\u003eFeatures integrated arc suppressors for relay contact protection.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eApplications\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eReal-time steady-state and transient dynamic data collection in 3500 machinery protection systems.\u003c\/li\u003e\n\u003cli\u003eEthernet communication interface between 3500 racks and System 1 Condition Monitoring and Diagnostic Software.\u003c\/li\u003e\n\u003cli\u003eRemote system configuration via 3500 System Configuration Software over TCP\/IP networks.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eOrdering Information\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003ePart Number \/ Option\u003c\/th\u003e\n\u003cth\u003eDescription\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e3500\/22-AA-BB-CC\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eTransient Data Interface Module and I\/O\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOption B: 01\u003c\/td\u003e\n\u003ctd\u003e10Base-T\/100Base-TX Ethernet I\/O Module\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOption B: 02\u003c\/td\u003e\n\u003ctd\u003e100Base-FX (Fiber Optic) Ethernet I\/O Module\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOption B: 03\u003c\/td\u003e\n\u003ctd\u003e10Base-T\/100Base-TX Ethernet I\/O Module with gold-plated OK Relay contacts\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOption B: 04\u003c\/td\u003e\n\u003ctd\u003e100Base-FX (Fiber Optic) Ethernet I\/O Module with gold-plated OK Relay contacts\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSpares\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e146031-01\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003e10Base-T\/100Base-TX I\/O Module\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e146031-02\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003e100Base-FX (Fiber Optic) I\/O Module\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e146031-03\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003e100Base-T\/100Base-TX I\/O Module GLD Plated\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e146031-04\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003e100Base-FX (Fiber Optic) I\/O Module GLD Plated\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable style=\"width: 100%;\"\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth style=\"width: 23.6287%;\"\u003eCategory\u003c\/th\u003e\n\u003cth style=\"width: 24.8945%;\"\u003eParameter\u003c\/th\u003e\n\u003cth style=\"width: 50.6329%;\"\u003eSpecification\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 23.6287%;\"\u003e\u003cstrong\u003eGeneral\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 24.8945%;\"\u003eManufacturer\u003c\/td\u003e\n\u003ctd style=\"width: 50.6329%;\"\u003eBently Nevada\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 23.6287%;\"\u003e \u003c\/td\u003e\n\u003ctd style=\"width: 24.8945%;\"\u003eModel\u003c\/td\u003e\n\u003ctd style=\"width: 50.6329%;\"\u003e146031-01\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 23.6287%;\"\u003e \u003c\/td\u003e\n\u003ctd style=\"width: 24.8945%;\"\u003eCompatible Module\u003c\/td\u003e\n\u003ctd style=\"width: 50.6329%;\"\u003e3500\/22M Transient Data Interface (TDI) Module\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 23.6287%;\"\u003e \u003c\/td\u003e\n\u003ctd style=\"width: 24.8945%;\"\u003eRack Space Requirements\u003c\/td\u003e\n\u003ctd style=\"width: 50.6329%;\"\u003e1 full-height rear slot\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 23.6287%;\"\u003e\u003cstrong\u003eCommunication\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 24.8945%;\"\u003eEthernet Type\u003c\/td\u003e\n\u003ctd style=\"width: 50.6329%;\"\u003e10Base-T \/ 100Base-TX, autosensing (Conforms to IEEE802.3)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 23.6287%;\"\u003e \u003c\/td\u003e\n\u003ctd style=\"width: 24.8945%;\"\u003eConnector Type\u003c\/td\u003e\n\u003ctd style=\"width: 50.6329%;\"\u003eRJ-45 (telephone jack style)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 23.6287%;\"\u003e \u003c\/td\u003e\n\u003ctd style=\"width: 24.8945%;\"\u003eProtocols Supported\u003c\/td\u003e\n\u003ctd style=\"width: 50.6329%;\"\u003eBN Host Protocol and BN TDI Protocol using Ethernet TCP\/IP\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 23.6287%;\"\u003e \u003c\/td\u003e\n\u003ctd style=\"width: 24.8945%;\"\u003eMaximum Cable Length\u003c\/td\u003e\n\u003ctd style=\"width: 50.6329%;\"\u003e100 meters (328 feet)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 23.6287%;\"\u003e\u003cstrong\u003eOK Relay\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 24.8945%;\"\u003eStandard Contact Rating\u003c\/td\u003e\n\u003ctd style=\"width: 50.6329%;\"\u003e5 A @ 24 Vdc \/ 120 Vac, 120 Watts \/ 600 VA Switched Power (maximum)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 23.6287%;\"\u003e \u003c\/td\u003e\n\u003ctd style=\"width: 24.8945%;\"\u003eOperation\u003c\/td\u003e\n\u003ctd style=\"width: 50.6329%;\"\u003eNormally Energized\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 23.6287%;\"\u003e \u003c\/td\u003e\n\u003ctd style=\"width: 24.8945%;\"\u003eContact Protection\u003c\/td\u003e\n\u003ctd style=\"width: 50.6329%;\"\u003eArc suppressors provided\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 23.6287%;\"\u003e\u003cstrong\u003eSystem Contacts\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 24.8945%;\"\u003eTrip Multiply Contact\u003c\/td\u003e\n\u003ctd style=\"width: 50.6329%;\"\u003e\u0026lt;1 mAdc, Dry Contact to Common\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 23.6287%;\"\u003e \u003c\/td\u003e\n\u003ctd style=\"width: 24.8945%;\"\u003eAlarm Inhibit Contact\u003c\/td\u003e\n\u003ctd style=\"width: 50.6329%;\"\u003e\u0026lt;1 mAdc, Dry Contact to Common\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 23.6287%;\"\u003e \u003c\/td\u003e\n\u003ctd style=\"width: 24.8945%;\"\u003eRack Reset Contact\u003c\/td\u003e\n\u003ctd style=\"width: 50.6329%;\"\u003e\u0026lt;1 mAdc, Dry Contact to Common\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 23.6287%;\"\u003e\u003cstrong\u003eEnvironmental\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 24.8945%;\"\u003eOperating Temperature\u003c\/td\u003e\n\u003ctd style=\"width: 50.6329%;\"\u003e-30 degC to +65 degC (-22 degF to +149 degF)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 23.6287%;\"\u003e \u003c\/td\u003e\n\u003ctd style=\"width: 24.8945%;\"\u003eStorage Temperature\u003c\/td\u003e\n\u003ctd style=\"width: 50.6329%;\"\u003e-40 degC to +85 degC (-40 degF to +185 degF)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 23.6287%;\"\u003e \u003c\/td\u003e\n\u003ctd style=\"width: 24.8945%;\"\u003eHumidity\u003c\/td\u003e\n\u003ctd style=\"width: 50.6329%;\"\u003e95%, non-condensing\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 23.6287%;\"\u003e\u003cstrong\u003eMechanical\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 24.8945%;\"\u003eDimensions (H x W x D)\u003c\/td\u003e\n\u003ctd style=\"width: 50.6329%;\"\u003e241.3 mm x 24.4 mm x 99.1 mm (9.50 in x 0.96 in x 3.90 in)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 23.6287%;\"\u003e \u003c\/td\u003e\n\u003ctd style=\"width: 24.8945%;\"\u003eWeight\u003c\/td\u003e\n\u003ctd style=\"width: 50.6329%;\"\u003e0.20 kg (0.44 lbs)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eConnections\/Interfaces\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003eConnector Pin \/ Interface\u003c\/th\u003e\n\u003cth\u003eFunction\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eOK RELAY\u003c\/td\u003e\n\u003ctd\u003eInternal termination header for OK Relay contacts (Selectable OPEN or CLOSED contact)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCOM \/ Signal Common\u003c\/td\u003e\n\u003ctd\u003e2-pin connector for connecting Signal Common to Instrument Ground\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRJ-45 Port\u003c\/td\u003e\n\u003ctd\u003eEthernet 10Base-T\/100Base-TX port for configuration and data collection\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSYSTEM CONTACTS (TM)\u003c\/td\u003e\n\u003ctd\u003eTrip Multiply input terminal (Dry Contact to Common)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSYSTEM CONTACTS (INHB)\u003c\/td\u003e\n\u003ctd\u003eAlarm Inhibit input terminal (Dry Contact to Common)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSYSTEM CONTACTS (RST)\u003c\/td\u003e\n\u003ctd\u003eRack Reset input terminal (Dry Contact to Common)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eInstallation Guidelines\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eUpgrade Sequence Advisory:\u003c\/strong\u003e When upgrading a 3500 rack from a 3500\/20 RIM to a 3500\/22 TDI, remove the existing RIM and RIM I\/O module before inserting the new TDI I\/O module and TDI front module to prevent damage to the TDI.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSlot Allocation:\u003c\/strong\u003e Install the module in the 1 full-height rear slot directly behind the 3500\/22M TDI module in Slot 1.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eGrounding Connection:\u003c\/strong\u003e Use the 2-pin Signal Common connector to attach Signal Common to a single-point Instrument Ground for the rack.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePower Input Module (PIM) Adjustment:\u003c\/strong\u003e When connecting Signal Common to Instrument Ground via the I\/O module, slide the selector switch on the side of the Power Input Module (PIM) in the direction of the arrow marked \"HP\" to isolate Signal Common from chassis ground.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eCompliance and Certifications\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eEMC:\u003c\/strong\u003e European Community Directive 2014\/30\/EU; EN 61000-6-2, EN 61000-6-4\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eElectrical Safety:\u003c\/strong\u003e European Community Directive 2014\/35\/EU; EN 61010-1\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRoHS:\u003c\/strong\u003e European Community Directive 2011\/65\/EU\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eFCC:\u003c\/strong\u003e Complies with part 15 of the FCC Rules\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMaritime:\u003c\/strong\u003e DNV GL rules for classification; ABS Rules for Condition of Classification\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eHazardous Area Approvals:\u003c\/strong\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003ecNRTLus:\u003c\/strong\u003e Class I, Zone 2: AEx\/Ex nA nC ic IIC T4 Gc; Class I, Zone 2: AEx\/Ex ec nC ic IIC T4 Gc; Class I, Division 2, Groups A, B, C, and D (T4 @ Ta = -20 degC to +65 degC)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eATEX\/IECEx:\u003c\/strong\u003e Ex II 3 G, Ex nA nC ic IIC T4 Gc, Ex ec nC ic IIC T4 Gc (T4 @ Ta = -20 degC to +65 degC)\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Bently Nevada","offers":[{"title":"Default Title","offer_id":52666865516907,"sku":"146031-01 3500\/22M","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/3227\/0443\/files\/bently-nevada-146031-01-transient-module-5waarynlxax_ca541a1e-7639-4df0-ae31-6efbdad78842.jpg?v=1765449431","url":"https:\/\/www.plcprotech.com\/products\/bently-nevada-146031-01-3500-22m-10base-t-100base-tx-i-o-module","provider":"PLC ProTech Ltd.","version":"1.0","type":"link"}