{"product_id":"bently-nevada-146054-032-10-02-cn-3300-xl-ceramic-capped-proximity-probe","title":"Bently Nevada 146054-032-10-02-CN 3300 XL Ceramic Capped Proximity Probe","description":"\u003ch3\u003eProduct Overview\u003c\/h3\u003e\n\u003cp\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e146054-032-10-02-CN\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e3300 XL Ceramic Capped Proximity Probe from\u003cspan\u003e \u003c\/span\u003e\u003cspan class=\"hover:entity-accent entity-underline inline cursor-pointer align-baseline\"\u003eBently Nevada\u003c\/span\u003e\u003cspan\u003e \u003c\/span\u003eis a high stability eddy current sensor designed for precise shaft vibration and axial position measurement in rotating machinery systems. It is commonly deployed in turbines, compressors, pumps, and generators operating in refinery, petrochemical, offshore, and power generation environments where continuous condition monitoring is required to prevent unplanned shutdowns.\u003c\/p\u003e\n\u003cp\u003eThe ceramic capped probe design improves thermal stability and wear resistance at the sensing tip, ensuring consistent signal linearity under harsh industrial conditions. With a 1.0 meter total length configuration and ClickLoc miniature coaxial connector, the probe provides stable signal transmission and reliable integration with 3300 XL Proximitor sensor systems in electrically noisy and high vibration installations.\u003c\/p\u003e\n\u003ch3\u003eTechnical Configuration\u003c\/h3\u003e\n\u003cp\u003eThe model structure defines mechanical length, connectivity, and approval configuration for system integration.\u003c\/p\u003e\n\u003ctable class=\"w-fit min-w-(--thread-content-width)\"\u003e\n\u003cthead\u003e\n\u003ctr class=\"firstRow\"\u003e\n\u003cth class=\"last:pe-10\"\u003eSegment\u003c\/th\u003e\n\u003cth class=\"last:pe-10\"\u003eDescription\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e146054\u003c\/td\u003e\n\u003ctd\u003e3300 XL ceramic capped probe series identifier\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e032\u003c\/td\u003e\n\u003ctd\u003eMechanical and probe configuration code\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e10\u003c\/td\u003e\n\u003ctd\u003eTotal length option 1.0 m (3.3 ft)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e02\u003c\/td\u003e\n\u003ctd\u003eMiniature coaxial ClickLoc connector with standard cable\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCN\u003c\/td\u003e\n\u003ctd\u003eCountry specific agency approval option\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003eThe ceramic capped sensing tip enhances durability in high temperature and abrasive shaft environments, improving long term measurement stability. The ClickLoc connector system ensures secure locking and minimizes signal loss due to vibration or connector micro-movement.\u003c\/p\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003ctable class=\"w-fit min-w-(--thread-content-width)\"\u003e\n\u003cthead\u003e\n\u003ctr class=\"firstRow\"\u003e\n\u003cth class=\"last:pe-10\"\u003eParameter\u003c\/th\u003e\n\u003cth class=\"last:pe-10\"\u003eSpecification\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003e146054-032-10-02-CN\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eBently Nevada\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOrigin\u003c\/td\u003e\n\u003ctd\u003eU.S.A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduct Type\u003c\/td\u003e\n\u003ctd\u003e3300 XL Ceramic Capped Proximity Probe\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTotal Length\u003c\/td\u003e\n\u003ctd\u003e1.0 m (3.3 ft)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eConnector Type\u003c\/td\u003e\n\u003ctd\u003eMiniature coaxial ClickLoc\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCable Type\u003c\/td\u003e\n\u003ctd\u003eStandard coaxial cable\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProbe Tip\u003c\/td\u003e\n\u003ctd\u003eCeramic capped design\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temp\u003c\/td\u003e\n\u003ctd\u003e-51 to +177 deg C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eStorage Temp\u003c\/td\u003e\n\u003ctd\u003e-51 to +177 deg C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e0.4 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eShipping Weight\u003c\/td\u003e\n\u003ctd\u003e1.5 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSystem Compatibility\u003c\/td\u003e\n\u003ctd\u003e3300 XL Proximitor sensor system\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eApplication\u003c\/td\u003e\n\u003ctd\u003eShaft vibration and displacement monitoring\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eFrequently Asked Questions\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eIs this probe compatible with standard 3300 XL Proximitor sensors?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eYes. It is fully compatible with Bently Nevada 3300 XL Proximitor systems.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eWhat is the benefit of the ceramic capped design?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eIt improves thermal resistance and reduces wear at the probe tip in harsh mechanical environments.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eCan it operate in high vibration environments?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eYes. The ClickLoc connector and rugged cable design support stable operation under continuous vibration.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eDoes CN option affect functionality?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eNo. CN defines regional certification and approval configuration only.\u003c\/p\u003e\n\u003chr\u003e\n\u003ch3\u003eInstallation and Engineering Guidelines\u003c\/h3\u003e\n\u003cp\u003eEnsure correct probe gap calibration during installation to maintain linear eddy current response across the measurement range.\u003c\/p\u003e\n\u003cp\u003eRoute probe cables away from high voltage and VFD output lines to minimize electromagnetic interference and signal distortion.\u003c\/p\u003e\n\u003cp\u003eVerify ClickLoc connector engagement until a full locking confirmation is achieved before system commissioning.\u003c\/p\u003e\n\u003cp\u003eMaintain proper mechanical alignment of the probe tip relative to shaft surface to avoid nonlinear signal behavior under high-speed rotation.\u003c\/p\u003e\n\u003ch3\u003e\u003c\/h3\u003e","brand":"Bently Nevada","offers":[{"title":"Default Title","offer_id":52668317827435,"sku":"146054-032-10-02-CN","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/3227\/0443\/files\/146054-032-10-02-cn-jlk4lwzd5fc_106c2b65-e0eb-4d64-afed-44908c9fbd61.jpg?v=1765521083","url":"https:\/\/www.plcprotech.com\/products\/bently-nevada-146054-032-10-02-cn-3300-xl-ceramic-capped-proximity-probe","provider":"PLC ProTech Ltd.","version":"1.0","type":"link"}