{"product_id":"bently-nevada-149986-01-3500-33-spare-16-channel-relay-control-module","title":"Bently Nevada 149986-01 3500\/33 Spare 16-Channel Relay Control Module","description":"\u003ch3\u003eDescription\u003c\/h3\u003e\n\u003cp\u003eThe \u003cstrong\u003e149986-01\u003c\/strong\u003e is a spare full-height front module component designed for the 3500\/33 16-Channel Relay Module within the 3500 Series Machinery Protection System. This module provides the core control logic and driving functions necessary to manage 16 independent relay outputs used for critical machinery alarms and voting logic configurations. It slots directly into any front chassis location to the right of the Transient Data Interface (TDI) Module and works in combination with a rear-mounted I\/O module to interface with external field wiring. The \u003cstrong\u003e149986-01\u003c\/strong\u003e processes inputs from monitor channels within the rack and utilizes programmable Alarm Drive Logic, supporting both AND and OR operations based on individual measured variables, alert or danger statuses, and Not-OK conditions.\u003c\/p\u003e\n\u003ch3\u003eFeatures\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eProcesses individual or combined monitor channel variables to drive complex alarm logic.\u003c\/li\u003e\n\u003cli\u003eFully programmable voting logic configurations manageable via the 3500 Rack Configuration Software.\u003c\/li\u003e\n\u003cli\u003eFront panel status indicators including a dedicated OK LED for system health and a TX\/RX LED for rack communication monitoring.\u003c\/li\u003e\n\u003cli\u003eProvides high-density alarm capability within a single full-height front slot of the 3500 rack chassis.\u003c\/li\u003e\n\u003cli\u003eSeamless integration into functional safety systems requiring restricted voltage outputs.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eApplications\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eHigh-density alarm and voting logic processing in industrial turbomachinery protection systems.\u003c\/li\u003e\n\u003cli\u003eCritical refinery asset protection requiring automated shutdown or alert notification control.\u003c\/li\u003e\n\u003cli\u003ePower generation gas and steam turbine safety voting networks.\u003c\/li\u003e\n\u003cli\u003eFunctional safety (SIL) automated monitoring environments.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eOrdering Information\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003ePart Number\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eDescription\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e149986-01\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eSpare 16-Channel Relay Control Module \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eManufacturer\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eBently Nevada (Baker Hughes) \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCountry of Origin\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eUSA \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eModule Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eFull-height Front Slot Module \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePower Consumption\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e5.8 watts typical \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDimensions (H x W x D)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e241 mm x 24.4 mm x 242 mm (9.50 in x 0.96 in x 9.52 in) \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eWeight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0.7 kg (1.6 lb) \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOperating Temperature\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e-20 degC to +65 degC (-4 deGF to +149 degF) \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRack Space Requirement\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1 full-height front slot \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eConnections\/Interfaces\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eComponent \/ LED\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eFunction\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOK LED\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eIlluminates when the control module is operating properly.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eTX\/RX LED\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eFlashes during transmit and receive operations when communicating with other rack modules.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eChannel Alarm LEDs\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eIndividual indicators that illuminate when a specific relay channel is in an alarm state.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eInstallation Guidelines\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eChassis Slot Placement:\u003c\/strong\u003e Install the \u003cstrong\u003e149986-01\u003c\/strong\u003e control module strictly in a front full-height slot located to the right of the rack's Transient Data Interface (TDI) module.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eNo Hot Insertion:\u003c\/strong\u003e Do not hot insert the module under any circumstances. Ensure rack power is isolated or disconnected prior to servicing to prevent module damage.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSoftware Version Control:\u003c\/strong\u003e Verify that the 3500 Rack Configuration Software is updated to version 3.3 or later, and Data Acquisition Software is at version 2.40 or later before provisioning.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eElectrostatic Discharge (ESD):\u003c\/strong\u003e Always utilize a grounding wrist strap when handling the control module to prevent static discharge from damaging sensitive internal microelectronics.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eCompliance and Certifications\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eFCC:\u003c\/strong\u003e Complies with part 15 of the FCC Rules.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eEMC Directives:\u003c\/strong\u003e 2014\/30\/EU (Standards: EN 61000-6-2, EN 61000-6-4).\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eElectrical Safety:\u003c\/strong\u003e Low Voltage Directive 2014\/35\/EU (Standard: EN 61010-1).\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRoHS:\u003c\/strong\u003e ROHS Directive 2011\/65\/EU.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMaritime:\u003c\/strong\u003e DNV GL rules for classification (Ships, offshore units, high speed and light craft); ABS Rules for Condition of Classification Part 1 (Steel Vessels, Offshore Units and Structures).\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eHazardous Area Approvals:\u003c\/strong\u003e Class I, Zone 2 (AEx\/Ex nA nC ic IIC T4 Gc \/ AEx\/Ex ec nC ic IIC T4 Gc); Class I, Division 2, Groups A, B, C, and D.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eATEX\/IECEx:\u003c\/strong\u003e Ex II 3 G (Ex nA nC ic IIC T4 Gc \/ Ex ec nC ic IIC T4 Gc).\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Bently Nevada","offers":[{"title":"Default Title","offer_id":52668303475051,"sku":"149986-01","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/3227\/0443\/files\/149986-01-eilcrhj53ry_fad1f76d-9de1-420a-adfa-017ccb904af8.jpg?v=1765520619","url":"https:\/\/www.plcprotech.com\/products\/bently-nevada-149986-01-3500-33-spare-16-channel-relay-control-module","provider":"PLC ProTech Ltd.","version":"1.0","type":"link"}