{"product_id":"bently-nevada-149992-01-3500-33-16-channel-relay-output-module","title":"Bently Nevada 149992-01 3500\/33 16-Channel Relay Output Module","description":"\u003ch3\u003eDescription\u003c\/h3\u003e\n\u003cp\u003eThe Bently Nevada \u003cstrong\u003e149992-01\u003c\/strong\u003e is a 16-channel relay output module designed for machinery protection and alarm expansion within the \u003cstrong\u003e3500 Series\u003c\/strong\u003e machinery monitoring system. Installed in a full-height rear slot of the 3500 rack, the module provides 16 independent relay outputs driven by Alarm Drive Logic to execute voting schemes based on alarming inputs, Not-OK conditions, or individual measured variables from monitoring channels across the system. It features epoxy-sealed single-pole double-throw (SPDT) relays equipped with built-in 250 Vrms arc suppressors and physical switch selection for Normally Energized (NE) or Normally De-energized (NDE) operation across four distinct channel groups.\u003c\/p\u003e\n\u003ch3\u003eFeatures\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eProvides 16 independently programmable single-pole double-throw (SPDT) relay output channels\u003c\/li\u003e\n\u003cli\u003eFeatures physical relay mode selection switches on the module for setting Normally Energized (NE) or Normally De-energized (NDE) operation in groups of four channels\u003c\/li\u003e\n\u003cli\u003eBuilt-in 250 Vrms relay arc suppressors installed as standard on contact outputs\u003c\/li\u003e\n\u003cli\u003eOnboard epoxy-sealed relay units designed for 10,000 cycles of contact life\u003c\/li\u003e\n\u003cli\u003eSupports independently programmed Alarm Drive Logic utilizing AND and OR voting logic configurations\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eApplications\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eTurbine machinery trip and emergency shutdown systems\u003c\/li\u003e\n\u003cli\u003eMachinery protection alarm expansion in oil and gas production\u003c\/li\u003e\n\u003cli\u003ePower generation plant rotating equipment monitoring\u003c\/li\u003e\n\u003cli\u003eIndustrial process alarm signaling and interlocking\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eOrdering Information\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003eOrdering Option \/ Part Number\u003c\/th\u003e\n\u003cth\u003eDescription\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e3500\/33-AA-BB\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e3500\/33 16-Channel Relay Module\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eA: Output Module Option\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e01\u003c\/td\u003e\n\u003ctd\u003e16-Channel Relay Output Module\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e02\u003c\/td\u003e\n\u003ctd\u003e16-Channel Failsafe Relay Output Module\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e03\u003c\/td\u003e\n\u003ctd\u003eLow Current 16-Channel Relay Output Module\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e04\u003c\/td\u003e\n\u003ctd\u003eLow Current 16-Channel Failsafe Relay Output Module\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eB: Hazardous Area Approval Option\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e00\u003c\/td\u003e\n\u003ctd\u003eNone\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e01\u003c\/td\u003e\n\u003ctd\u003eCNRTLUS (Class 1, Division 2)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e02\u003c\/td\u003e\n\u003ctd\u003eATEX \/ IECEx \/ CSA (Class 1, Zone 2)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSpares\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e149986-01\u003c\/td\u003e\n\u003ctd\u003eSpare 16-Channel Relay Control Module\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e149992-01\u003c\/td\u003e\n\u003ctd\u003eSpare 16-Channel Relay Output Module\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e149992-02\u003c\/td\u003e\n\u003ctd\u003eSpare 16-Channel Failsafe Relay Output Module\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e149992-03\u003c\/td\u003e\n\u003ctd\u003eSpare 16-Channel Low Current Relay Output Module\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e149992-04\u003c\/td\u003e\n\u003ctd\u003eSpare 16-Channel Low Current Failsafe Relay Output Module\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e04425545\u003c\/td\u003e\n\u003ctd\u003eGrounding Wrist Strap (single use)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e162291\u003c\/td\u003e\n\u003ctd\u003e16-Channel Relay Module User Guide\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e00580453\u003c\/td\u003e\n\u003ctd\u003eConnector Header Internal Termination 16-position Green\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e166M2381\u003c\/td\u003e\n\u003ctd\u003eConnector Header Push-in-Spring Type\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003eCategory\u003c\/th\u003e\n\u003cth\u003eParameter\u003c\/th\u003e\n\u003cth\u003eSpecification\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePhysical\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eI\/O Module Dimensions (H x W x D)\u003c\/td\u003e\n\u003ctd\u003e241 mm x 24.4 mm x 99.1 mm (9.50 in x 0.96 in x 3.90 in)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003eI\/O Module Weight\u003c\/td\u003e\n\u003ctd\u003e0.4 kg (1.0 lb)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003eRack Space Requirements\u003c\/td\u003e\n\u003ctd\u003e1 full-height rear slot\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eElectrical\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003ePower Consumption\u003c\/td\u003e\n\u003ctd\u003e5.8 watts typical\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003eRelay Type\u003c\/td\u003e\n\u003ctd\u003eSingle-pole Double-throw (SPDT)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003eRelay Environmental Sealing\u003c\/td\u003e\n\u003ctd\u003eEpoxy-sealed\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003eRelay Arc Suppressor\u003c\/td\u003e\n\u003ctd\u003e250 Vrms installed as standard\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003eRelay Contact Life\u003c\/td\u003e\n\u003ctd\u003e10,000 cycles\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eStandard Relays (DC)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eMin Switched Current\u003c\/td\u003e\n\u003ctd\u003e100 mA @ 5 Vdc\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003eMax Switched Current\u003c\/td\u003e\n\u003ctd\u003e5 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003eMax Switched Power\u003c\/td\u003e\n\u003ctd\u003e70 W @ 24 Vdc, 10 W @ 48 Vdc, 9 W @ 60 Vdc\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003eMax Switched Voltage\u003c\/td\u003e\n\u003ctd\u003e125 Vdc (30 Vdc for Failsafe\/Hazardous Area Systems)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eStandard Relays (AC)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eMin Switched Current\u003c\/td\u003e\n\u003ctd\u003e100 mA @ 5 Vdc\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003eMax Switched Current\u003c\/td\u003e\n\u003ctd\u003e5 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003eMax Switched Power\u003c\/td\u003e\n\u003ctd\u003e1200 VA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003eMax Switched Voltage\u003c\/td\u003e\n\u003ctd\u003e250 Vac\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eConnections\/Interfaces\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003eConnector Pin\u003c\/th\u003e\n\u003cth\u003eFunction\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eNC\u003c\/td\u003e\n\u003ctd\u003eNormally Closed Contact\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eARM\u003c\/td\u003e\n\u003ctd\u003eRelay Armature (Common Contact)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNO\u003c\/td\u003e\n\u003ctd\u003eNormally Open Contact\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eInstallation Guidelines\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eEnsure power to the module\/slot is disconnected prior to servicing or maintenance when installed in live environments.\u003c\/li\u003e\n\u003cli\u003eFollow static-sensitive handling procedures and utilize a grounding wrist strap during installation.\u003c\/li\u003e\n\u003cli\u003eEnsure proper terminal wiring to the 16-position internal termination green connector header or push-in spring header.\u003c\/li\u003e\n\u003cli\u003eSet the Relay Mode Selection Switch on the side of the I\/O module to NDE or NE for channels 1-4, 5-8, 9-12, and 13-16 prior to final mounting.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eCompliance and Certifications\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003eCertification \/ Standard\u003c\/th\u003e\n\u003cth\u003eDetail\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eFCC\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eComplies with Part 15 of FCC Rules\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eEMC\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eEuropean Community Directive 2014\/30\/EU; Standards: EN 61000-6-2, EN 61000-6-4\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eElectrical Safety\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eEuropean Community Directive 2014\/35\/EU; Standard: EN 61010-1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eROHS\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eEuropean Community Directive 2011\/65\/EU\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMaritime\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eDNV GL rules for classification; ABS Rules for Condition of Classification (Steel Vessels Rules, Offshore Units and Structures)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eHazardous Area Approvals\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003ecNRTLus: Class I, Zone 2: AEx\/Ex nA nC ic IIC T4 Gc; Class I, Zone 2: AEx\/Ex ec nC ic IIC T4 Gc; Class I, Division 2, Groups A, B, C, D; T4 @ Ta = -20 degC to +65 degC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003eATEX\/IECEx: Ex II 3 G, Ex nA nC ic IIC T4 Gc, Ex ec nC ic IIC T4 Gc; T4 @ Ta = -20 degC to +65 degC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e","brand":"Bently Nevada","offers":[{"title":"Default Title","offer_id":52666861945195,"sku":"149992-01","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/3227\/0443\/files\/bently-nevada-149992-01-relay-output-module-hb1n3kl13yj_c3d7b158-b5ce-414e-929f-e72c4d114be6.jpg?v=1765449325","url":"https:\/\/www.plcprotech.com\/products\/bently-nevada-149992-01-3500-33-16-channel-relay-output-module","provider":"PLC ProTech Ltd.","version":"1.0","type":"link"}