{"product_id":"bently-nevada-149992-02-spare-16-channel-failsafe-relay-output-module","title":"Bently Nevada 149992-02 Spare 16-Channel Failsafe Relay Output Module","description":"\u003ch3\u003eDescription\u003c\/h3\u003e\n\u003cp\u003eThe \u003cstrong\u003eBently Nevada 149992-02\u003c\/strong\u003e is a \u003cstrong\u003eSpare 16-Channel Failsafe Relay Output Module\u003c\/strong\u003e designed for emergency shutdown logic and machinery protection within the Bently Nevada 3500 Machinery Protection System. Operating as the dedicated rear I\/O component paired with the 3500\/33 16-Channel Relay Control Module, the \u003cstrong\u003e149992-02\u003c\/strong\u003e provides 16 single-pole double-throw (SPDT) relay output channels equipped with standard epoxy-sealed electromechanical contacts and 250 Vrms relay arc suppressors. The module receives programmed voting logic commands from the front main module via the 3500 rack backplane, supporting complex AND\/OR Alarm Drive Logic based on alert\/danger statuses, Not-OK conditions, and individual measured variables from monitoring channels.\u003c\/p\u003e\n\u003ch3\u003eFeatures\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eProvides 16 independent single-pole double-throw (SPDT) relay channels for machinery alarm and shutdown drive outputs.\u003c\/li\u003e\n\u003cli\u003eConfigured with standard silver relay contacts suitable for standard switching applications.\u003c\/li\u003e\n\u003cli\u003eIntegrated with standard 250 Vrms relay arc suppressors on each output contact.\u003c\/li\u003e\n\u003cli\u003eFeatures DIP switch selectable operation for four groups of four channels to set Normally De-energized (ND) or Normally Energized (NE) modes.\u003c\/li\u003e\n\u003cli\u003eAccepts direct field wiring via a 16-position green internal termination connector header.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eApplications\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eEmergency machinery shutdown and protective tripping systems.\u003c\/li\u003e\n\u003cli\u003eExternal alarm drive and annunciation signal routing.\u003c\/li\u003e\n\u003cli\u003eMachinery protection interfacing within Bently Nevada 3500 system racks.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eOrdering Information\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003ePart Number\u003c\/th\u003e\n\u003cth\u003eDescription\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e3500\/33-AA-BB\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003e16-Channel Relay Module\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003ci\u003eA: Output Module Option\u003c\/i\u003e\u003c\/td\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e01\u003c\/td\u003e\n\u003ctd\u003e16-Channel Relay Output Module\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e02\u003c\/td\u003e\n\u003ctd\u003e16-Channel Failsafe Relay Output Module\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e03\u003c\/td\u003e\n\u003ctd\u003eLow Current 16-Channel Relay Output Module\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e04\u003c\/td\u003e\n\u003ctd\u003eLow Current 16-Channel Failsafe Relay Output Module\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003ci\u003eB: Agency Approval Option\u003c\/i\u003e\u003c\/td\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e00\u003c\/td\u003e\n\u003ctd\u003eNone\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e01\u003c\/td\u003e\n\u003ctd\u003ecNRTLus (Class 1, Division 2)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e02\u003c\/td\u003e\n\u003ctd\u003eATEX \/ IECEx \/ CSA (Class 1, Zone 2)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSpares\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e149986-01\u003c\/td\u003e\n\u003ctd\u003eSpare 16-Channel Relay Control Module\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e149992-01\u003c\/td\u003e\n\u003ctd\u003eSpare 16-Channel Relay Output Module\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e149992-02\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eSpare 16-Channel Failsafe Relay Output Module\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e149992-03\u003c\/td\u003e\n\u003ctd\u003eSpare 16-Channel Low Current Relay Output Module\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e149992-04\u003c\/td\u003e\n\u003ctd\u003eSpare 16-Channel Low Current Failsafe Relay Output Module\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eAccessories\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e00580453\u003c\/td\u003e\n\u003ctd\u003eConnector Header Internal Termination 16-position Green\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e166M2381\u003c\/td\u003e\n\u003ctd\u003eConnector Header Push-in-Spring Type (Alternative for PN 00580453)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e04425545\u003c\/td\u003e\n\u003ctd\u003eGrounding Wrist Strap (single use)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003eCategory\u003c\/th\u003e\n\u003cth\u003eParameter\u003c\/th\u003e\n\u003cth\u003eValue\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBasic Information\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eManufacturer\u003c\/td\u003e\n\u003ctd\u003eBently Nevada\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003eModule Type\u003c\/td\u003e\n\u003ctd\u003eSpare 16-Channel Failsafe Relay Output Module\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePhysical Specifications\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eSlot Requirement\u003c\/td\u003e\n\u003ctd\u003e1 full-height rear slot\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003eDimensions (H x W x D)\u003c\/td\u003e\n\u003ctd\u003e241 mm x 24.4 mm x 99.1 mm (9.50 in x 0.96 in x 3.90 in)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e0.4 kg (1.0 lb)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRelay Specifications\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eRelay Type\u003c\/td\u003e\n\u003ctd\u003eSingle-pole Double-throw (SPDT) Relay\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003eRelay Sealing\u003c\/td\u003e\n\u003ctd\u003eEpoxy-sealed\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003eRelay Arc Suppressor\u003c\/td\u003e\n\u003ctd\u003e250 Vrms (installed as standard)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003eRelay Contact Life\u003c\/td\u003e\n\u003ctd\u003e10,000 cycles\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003eRelay Operation\u003c\/td\u003e\n\u003ctd\u003e4 groups of 4 channels switch selectable for Normally De-energized (ND) or Normally Energized (NE)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eContact Ratings (Standard Relays)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eMinimum Switched Load\u003c\/td\u003e\n\u003ctd\u003e100 mA @ 5 Vdc\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003eMaximum Switched Current\u003c\/td\u003e\n\u003ctd\u003e5 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003eMaximum Switched Voltage (DC)\u003c\/td\u003e\n\u003ctd\u003e30 Vdc (Failsafe \/ Hazardous Area Systems)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003eMaximum Switched Voltage (AC)\u003c\/td\u003e\n\u003ctd\u003e250 Vac\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003eMaximum Switched Power (AC)\u003c\/td\u003e\n\u003ctd\u003e1200 VA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003eMaximum Switched Power (DC)\u003c\/td\u003e\n\u003ctd\u003e70 W @ 24 Vdc \/ 10 W @ 48 Vdc \/ 9 W @ 60 Vdc\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSoftware Requirements\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eRack Configuration\u003c\/td\u003e\n\u003ctd\u003e3500 Rack Config, version 3.3 or later\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003eData Acquisition\u003c\/td\u003e\n\u003ctd\u003e3500 Data Acquisition Software, version 2.40 or later\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003eData Display\u003c\/td\u003e\n\u003ctd\u003e3500 Data Display Software, version 1.40 or later\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eInstallation Guidelines\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eInstall the module into a dedicated 1 full-height rear slot directly behind the corresponding 3500\/33 main control module in the 3500 rack.\u003c\/li\u003e\n\u003cli\u003eDo not hot insert the module to prevent electrical damage.\u003c\/li\u003e\n\u003cli\u003eSelect Normally De-energized (NDE) or Normally Energized (NE) modes for each 4-channel group using the RELAY MODE DIP switches on the side of the module prior to installation.\u003c\/li\u003e\n\u003cli\u003eConnect field wiring to the 16-position green terminal block connector header (PN 00580453) or optional push-in spring header (PN 166M2381).\u003c\/li\u003e\n\u003cli\u003eEnsure proper grounding procedures and wear a grounding wrist strap during installation and handling.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eCompliance and Certifications\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003eStandard \/ Directive\u003c\/th\u003e\n\u003cth\u003eCertification \/ Approval\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eFCC\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003ePart 15 Class A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eEMC Directive\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e2014\/30\/EU; EN 61000-6-2, EN 61000-6-4\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eElectrical Safety\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eLV Directive 2014\/35\/EU; EN 61010-1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRoHS Directive\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e2011\/65\/EU\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMaritime\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eDNV GL rules for classification; ABS Rules for Condition of Classification\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eHazardous Area (cNRTLus)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eClass I, Zone 2: AEx\/Ex nA nC ic IIC T4 Gc; Class I, Zone 2: AEx\/Ex ec nC ic IIC T4 Gc; Class I, Division 2, Groups A, B, C, D; T4 @ Ta = -20 degC to +65 degC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eHazardous Area (ATEX\/IECEx)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eII 3 G; Ex nA nC ic IIC T4 Gc; Ex ec nC ic IIC T4 Gc; T4 @ Ta = -20 degC to +65 degC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e","brand":"Bently Nevada","offers":[{"title":"Default Title","offer_id":52666868040043,"sku":"149992-02","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/3227\/0443\/files\/bently-nevada-149992-02-16-channel-relay-module-qmua0btiafp_e3b416c8-80e2-48fb-bb85-305b97f34e68.jpg?v=1765449528","url":"https:\/\/www.plcprotech.com\/products\/bently-nevada-149992-02-spare-16-channel-failsafe-relay-output-module","provider":"PLC ProTech Ltd.","version":"1.0","type":"link"}