{"product_id":"bently-nevada-16710-07-interconnect-cables","title":"Bently Nevada 16710-07 Interconnect Cables","description":"\u003ch3\u003eDescription\u003c\/h3\u003e\nThe \u003cstrong\u003e16710-07\u003c\/strong\u003e is an armored interconnect cable designed for use with Bently Nevada acceleration transducer systems, specifically the 330400 and 330425 series. This cable features a 3-conductor shielded 22 AWG (0.5 mm2) configuration, engineered to maintain signal integrity in demanding industrial environments where mechanical protection is required. This specific configuration, 16710-07, provides a total cable length of 7 feet (2.13 meters), ending in a 3-socket plug at the transducer interface and terminal lugs at the monitor or junction box interface.\n\nAs an essential component in condition monitoring chains, the 16710-07 ensures reliable transmission of vibration data from the sensor to the monitoring instrumentation. The rugged armored jacket provides resistance against abrasion and incidental impact common in rotating machinery applications, such as gearboxes, motors, and pumps.\n\n\u003ch3\u003eFeatures\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eLength: 7 feet (2.13 meters)\u003c\/li\u003e\n\u003cli\u003eCable Type: 3-conductor shielded 22 AWG (0.5 mm2) armored cable\u003c\/li\u003e\n\u003cli\u003eConnectors: 3-socket plug at one end, terminal lugs at the other\u003c\/li\u003e\n\u003cli\u003eShielding: Integrated shield to minimize electromagnetic interference (EMI)\u003c\/li\u003e\n\u003cli\u003eDurability: Armored jacket for enhanced mechanical protection\u003c\/li\u003e\n\u003cli\u003eCompatibility: Designed for use with 330400 and 330425 accelerometer transducers\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eApplications\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eCasing vibration monitoring on critical rotating machinery\u003c\/li\u003e\n\u003cli\u003eGear mesh monitoring in gearboxes\u003c\/li\u003e\n\u003cli\u003eGeneral-purpose industrial acceleration measurements\u003c\/li\u003e\n\u003cli\u003eHarsh environments requiring abrasion-resistant cabling\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eOrdering Information\u003c\/h3\u003e\n\u003ctable\u003e\n\u003ctr\u003e\n\u003ctd\u003eOrderable Part Number\u003c\/td\u003e\n\u003ctd\u003e16710-07\u003c\/td\u003e\n\u003ctd\u003e330400\/330425 Interconnect Cable\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCable Length\u003c\/td\u003e\n\u003ctd\u003e07\u003c\/td\u003e\n\u003ctd\u003e7.0 ft (2.13 m)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\n\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003ctable\u003e\n\u003ctr\u003e\n\u003ctd\u003eManufacturer\u003c\/td\u003e\n\u003ctd\u003eBently Nevada\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePart Number\u003c\/td\u003e\n\u003ctd\u003e16710-07\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eConductor Size\u003c\/td\u003e\n\u003ctd\u003e22 AWG (0.5 mm2)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eShielding\u003c\/td\u003e\n\u003ctd\u003eShielded\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eArmor\u003c\/td\u003e\n\u003ctd\u003eArmored\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eLength\u003c\/td\u003e\n\u003ctd\u003e7.0 ft (2.13 m)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eConnector (Transducer End)\u003c\/td\u003e\n\u003ctd\u003e3-socket plug\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eConnector (Termination End)\u003c\/td\u003e\n\u003ctd\u003eTerminal lugs\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\n\n\u003ch3\u003eInstallation Guidelines\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eEnsure the mating connector provides IP54 ingress protection or better if installed in hazardous areas.\u003c\/li\u003e\n\u003cli\u003eRoute cables in protected conduit to prevent physical damage and electrical noise interference.\u003c\/li\u003e\n\u003cli\u003eAvoid sharp bends near the connector assembly to maintain seal integrity and prevent conductor fatigue.\u003c\/li\u003e\n\u003cli\u003eUse the provided terminal lugs for secure, low-resistance connections at the monitor or junction box termination point.\u003c\/li\u003e\n\u003cli\u003eCheck that the total cable run does not exceed the system limitations for signal degradation.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eCompliance and Certifications\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eRoHS Directive 2011\/65\/EU\u003c\/li\u003e\n\u003cli\u003eChina RoHS: EFUP designation of 15 years (SJ\/T 11364-2024)\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Bently Nevada","offers":[{"title":"Default Title","offer_id":52666859323755,"sku":"16710-07","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/3227\/0443\/files\/bently-nevada-16710-07-interconnect-cable-ghwqlgskjnf_0bf320c6-7846-4023-aae2-aca1c064cdc0.jpg?v=1765449253","url":"https:\/\/www.plcprotech.com\/products\/bently-nevada-16710-07-interconnect-cables","provider":"PLC ProTech Ltd.","version":"1.0","type":"link"}