{"product_id":"bently-nevada-16925-26-interconnect-cable","title":"Bently Nevada 16925-26 Interconnect Cable","description":"\u003ch3\u003eDescription\u003c\/h3\u003e\n\u003cp\u003eThe \u003cstrong\u003e16925-26\u003c\/strong\u003e is a high-quality 3-conductor shielded 22 AWG (0.5 mm2) interconnect cable designed for critical machinery casing vibration monitoring. This specific configuration features a total length of 26 ft (7.9 m), equipped with a 3-socket plug at one end and terminal lugs at the other end for secure, reliable signal transmission.\u003c\/p\u003e\n\n\u003cp\u003eUsed primarily to connect 330400 and 330425 series acceleration transducers to vibration monitoring systems, this cable ensures signal integrity in demanding industrial environments. The durable design includes a shielded construction to minimize electromagnetic interference, supporting the accurate delivery of acceleration data from the accelerometer on the machine housing or bearing cap back to the monitoring instrumentation.\u003c\/p\u003e\n\n\u003ch3\u003eFeatures\u003c\/h3\u003e\n\u003cul\u003e\n    \u003cli\u003e3-conductor shielded 22 AWG (0.5 mm2) construction\u003c\/li\u003e\n    \u003cli\u003e3-socket plug connector at one end\u003c\/li\u003e\n    \u003cli\u003eTerminal lugs at the other end for direct termination\u003c\/li\u003e\n    \u003cli\u003eOptimized for use with 330400 and 330425 acceleration transducers\u003c\/li\u003e\n    \u003cli\u003eDurable shielding to protect signal integrity in high-EMI environments\u003c\/li\u003e\n    \u003cli\u003eStandardized 26 ft (7.9 m) length\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eApplications\u003c\/h3\u003e\n\u003cul\u003e\n    \u003cli\u003eCritical machinery protection and monitoring\u003c\/li\u003e\n    \u003cli\u003eCasing acceleration measurements\u003c\/li\u003e\n    \u003cli\u003eGear mesh and bearing housing vibration analysis\u003c\/li\u003e\n    \u003cli\u003eIndustrial machinery in petrochemical, power generation, and water treatment sectors\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eOrdering Information\u003c\/h3\u003e\n\u003ctable\u003e\n    \u003ctr\u003e\n        \u003cth\u003eOption\u003c\/th\u003e\n        \u003cth\u003eCode on This SKU\u003c\/th\u003e\n        \u003cth\u003eDescription\u003c\/th\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n        \u003ctd\u003eOrderable Part Number\u003c\/td\u003e\n        \u003ctd\u003e16925-26\u003c\/td\u003e\n        \u003ctd\u003e330400\/330425 Interconnect Cable\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n        \u003ctd\u003eCable Length\u003c\/td\u003e\n        \u003ctd\u003e26\u003c\/td\u003e\n        \u003ctd\u003e26 ft (7.9 m)\u003c\/td\u003e\n    \u003c\/tr\u003e\n\u003c\/table\u003e\n\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003ctable\u003e\n    \u003ctr\u003e\n        \u003cth\u003eParameter\u003c\/th\u003e\n        \u003cth\u003eSpecification\u003c\/th\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n        \u003ctd\u003eManufacturer\u003c\/td\u003e\n        \u003ctd\u003eBently Nevada (Baker Hughes)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n        \u003ctd\u003ePart Number\u003c\/td\u003e\n        \u003ctd\u003e16925-26\u003c\/td\u003e\n        \u003c\/tr\u003e\n    \u003ctr\u003e\n        \u003ctd\u003eCable Type\u003c\/td\u003e\n        \u003ctd\u003e3-conductor shielded 22 AWG (0.5 mm2)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n        \u003ctd\u003eConnector (Sensor End)\u003c\/td\u003e\n        \u003ctd\u003e3-socket plug\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n        \u003ctd\u003eTermination (System End)\u003c\/td\u003e\n        \u003ctd\u003eTerminal lugs\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n        \u003ctd\u003eTotal Length\u003c\/td\u003e\n        \u003ctd\u003e26 ft (7.9 m)\u003c\/td\u003e\n    \u003c\/tr\u003e\n\u003c\/table\u003e\n\n\u003ch3\u003eInstallation Guidelines\u003c\/h3\u003e\n\u003cp\u003eFor optimal performance, install the 16925-26 cable within protective conduit to prevent physical damage and minimize environmental exposure. Ensure that the sensor end connector is fully seated to maintain signal integrity. Avoid routing signal cables near high-voltage power lines to minimize potential electromagnetic interference. When terminating the lug end, ensure clean, secure contact at the terminal block to maintain the accuracy of the vibration monitoring system.\u003c\/p\u003e","brand":"Bently Nevada","offers":[{"title":"Default Title","offer_id":52666864271723,"sku":"16925-26","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/3227\/0443\/files\/bently-nevada-16925-26-electrical-cable-wire-2fxiuzakbhh_c032e948-b916-4121-996b-c582b153e99d.jpg?v=1765449394","url":"https:\/\/www.plcprotech.com\/products\/bently-nevada-16925-26-interconnect-cable","provider":"PLC ProTech Ltd.","version":"1.0","type":"link"}