{"product_id":"bently-nevada-190501-00-00-04-velomitor-ct-velocity-transducer","title":"Bently Nevada 190501-00-00-04 Velomitor CT Velocity Transducer","description":"\u003ch3\u003eDescription\u003c\/h3\u003e\n\u003cp\u003eEngineered for industrial vibration monitoring under low-frequency conditions, the \u003cstrong\u003eBently Nevada 190501-00-00-04\u003c\/strong\u003e is a highly specialized \u003cstrong\u003eVelomitor CT Velocity Transducer\u003c\/strong\u003e. It is commonly deployed to monitor physical displacement and velocity in slow-speed machinery, particularly cooling tower fans. Encased in a rugged, corrosion-resistant 316L stainless steel housing, this sensor reliably captures vibration signatures and transmits them directly to machinery protection systems.\u003c\/p\u003e\n\n\u003cp\u003eThis specific configuration includes multiple agency approvals for deployment in hazardous areas and utilizes a top-mounted 2-pin MIL-C-5015 electrical interface. The transducer operates without a pre-installed mounting stud, enabling custom mechanical integration depending on system requirements. It provides direct compatibility with continuous monitoring racks and distributed control networks to support preventative maintenance programs.\u003c\/p\u003e\n\n\u003ch3\u003eFeatures\u003c\/h3\u003e\n\u003cul\u003e\n  \u003cli\u003e\n\u003cstrong\u003eIndustrial Durability:\u003c\/strong\u003e Constructed from hermetically sealed 316L stainless steel to withstand high humidity and corrosive environments.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eTop Connection Interface:\u003c\/strong\u003e Standardized 2-pin MIL-C-5015 connector ensures secure and clean signal pathing.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eHazardous Location Ready:\u003c\/strong\u003e Outfitted with multiple agency approvals (Option 04) for installation in explosive and volatile atmospheres.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eCooling Tower Optimized:\u003c\/strong\u003e Tailored frequency response curves designed to isolate low-frequency vibration anomalies.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eApplications\u003c\/h3\u003e\n\u003cul\u003e\n  \u003cli\u003eCooling tower fans and air-cooled heat exchangers\u003c\/li\u003e\n  \u003cli\u003eSlow-speed gearboxes and drive shafts\u003c\/li\u003e\n  \u003cli\u003eWater and wastewater aeration equipment\u003c\/li\u003e\n  \u003cli\u003eIndustrial ventilation systems\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003ctable\u003e\n  \u003ctbody\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eManufacturer\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003eBently Nevada\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003ePart Number \/ Model\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e190501-00-00-04\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eTransducer Type\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003eVelomitor CT (Cooling Tower) Velocity Transducer\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eMounting Hardware Option\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e00 (No mounting stud included)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eConnection Option\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e00 (MIL-C-5015 top-entry connector)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eAgency Approval Option\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e04 (Multiple international approvals)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eCase Material\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e316L stainless steel\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eConnector Design\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e2-pin MIL-C-5015, top-mounted, 316L stainless steel\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eMounting Surface Requirements\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003eMinimum 33 mm (1.3 in) diameter flat surface\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eRecommended Mounting Torque\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e4.5 N-m +\/- 0.6 N-m (40 in-lbf +\/- 5 in-lbf)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eOperating Temperature Range\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e-40 degC to +85 degC (-40 degF to +185 degF)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eStorage Temperature Range\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e-40 degC to +100 degC (-40 degF to +212 degF)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eHeight\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e8.2 cm (3.2 in)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eTransducer Weight\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e0.297 kg (0.65 lbs)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eCountry of Origin\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003eUSA\u003c\/td\u003e\n    \u003c\/tr\u003e\n  \u003c\/tbody\u003e\n\u003c\/table\u003e\n\n\u003ch3\u003eConnections and Interfaces\u003c\/h3\u003e\n\u003ctable\u003e\n  \u003cthead\u003e\n    \u003ctr\u003e\n      \u003cth\u003eMIL-C-5015 Pin\u003c\/th\u003e\n      \u003cth\u003eFunction Description\u003c\/th\u003e\n    \u003c\/tr\u003e\n  \u003c\/thead\u003e\n  \u003ctbody\u003e\n    \u003ctr\u003e\n      \u003ctd\u003ePin A\u003c\/td\u003e\n      \u003ctd\u003eSignal \/ Positive Output\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003ePin B\u003c\/td\u003e\n      \u003ctd\u003eCommon \/ Return\u003c\/td\u003e\n    \u003c\/tr\u003e\n  \u003c\/tbody\u003e\n\u003c\/table\u003e\n\n\u003ch3\u003eInstallation Guidelines\u003c\/h3\u003e\n\u003cp\u003eProper installation is vital for achieving accurate low-frequency measurements. Ensure the following preparation and installation procedures are met:\u003c\/p\u003e\n\u003cul\u003e\n  \u003cli\u003e\n\u003cstrong\u003eSurface Preparation:\u003c\/strong\u003e The mounting surface must be machined flat to a minimum of 33 mm in diameter to prevent high-frequency attenuation.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eTorque Control:\u003c\/strong\u003e Always use a calibrated torque wrench to secure the transducer. Exceeding the specified 4.5 N-m torque rating can lead to internal sensing element damage, while under-torqueing degrades signal accuracy.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eCable Protection:\u003c\/strong\u003e Route and secure field wiring with appropriate strain relief to prevent mechanical stress on the MIL-C-5015 connection point. Use conduit or armor in harsh physical environments.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eCompliance and Certifications\u003c\/h3\u003e\n\u003cul\u003e\n  \u003cli\u003eOption 04 multiple agency approvals for hazardous environments (includes North American, ATEX, and IECEx certifications for Zone\/Class divisions).\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Bently Nevada","offers":[{"title":"Default Title","offer_id":52668309438827,"sku":"190501-00-00-04","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/3227\/0443\/files\/190501-00-00-04-1sio4bh53wu_7c870220-62bb-4fda-b1e6-3c1d0715a8d8.jpg?v=1765520796","url":"https:\/\/www.plcprotech.com\/products\/bently-nevada-190501-00-00-04-velomitor-ct-velocity-transducer","provider":"PLC ProTech Ltd.","version":"1.0","type":"link"}