{"product_id":"bently-nevada-21000-16-05-00-103-03-02-proximity-probe-housing-assembly","title":"Bently Nevada 21000-16-05-00-103-03-02 Proximity Probe Housing Assembly","description":"\u003ch3\u003eDescription\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003e21000-16-05-00-103-03-02\u003c\/strong\u003e: 3300 XL 8 mm proximity probe housing assembly, featuring Option 16 (3300 XL 8 mm probe), Option 05 (0.5 m probe cable), Option 00 (no standoff adapter), Option 103 (10.3 in probe penetration), Option 03 (cable seal grip), and Option 02 (3\/4-14 NPT mounting thread).\u003c\/p\u003e\n\u003cp\u003eThis Bently Nevada 21000 series housing assembly is a standardized, externally mounted solution used for securing proximity probes in industrial rotating machinery applications. It provides a robust, environmentally sealed environment for the transducer system, protecting the probe and cable connection while facilitating precise axial position and vibration monitoring. This configuration is engineered for standard industrial environments, utilizing an aluminum body with a 304 stainless steel sleeve to ensure structural integrity and effective thermal management for the installed 3300 XL 8 mm probe.\u003c\/p\u003e\n\n\u003ch3\u003eFeatures\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eOption 16: Includes a factory-integrated 3300 XL 8 mm proximity probe\u003c\/li\u003e\n\u003cli\u003eOption 05: Equipped with a 0.5 m (20 in) probe cable for compact connection requirements\u003c\/li\u003e\n\u003cli\u003eOption 103: Precise 10.3 inch (261.6 mm) probe penetration depth\u003c\/li\u003e\n\u003cli\u003eOption 03: Cable seal grip fitting provides secure, weather-resistant ingress protection\u003c\/li\u003e\n\u003cli\u003eOption 02: Standard 3\/4-14 NPT mounting thread for straightforward installation into machine casings\u003c\/li\u003e\n\u003cli\u003eOption 00: Direct mount configuration without standoff adapter for space-constrained installations\u003c\/li\u003e\n\u003cli\u003eConstruction: Aluminum body with 304 stainless steel sleeve for resistance to vibration and environmental factors\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eApplications\u003c\/h3\u003e\n\u003cp\u003eThis proximity probe housing assembly is used in heavy industrial sectors for monitoring critical rotating machinery, including:\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eSteam and gas turbines\u003c\/li\u003e\n\u003cli\u003eCentrifugal compressors and blowers\u003c\/li\u003e\n\u003cli\u003eLarge electric motors and generators\u003c\/li\u003e\n\u003cli\u003eReciprocating compressors (where non-contact monitoring is required)\u003c\/li\u003e\n\u003cli\u003ePumps and gearboxes in petrochemical and refining facilities\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eOrdering Information\u003c\/h3\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003eOption\u003c\/th\u003e\n\u003cth\u003eCode on This SKU\u003c\/th\u003e\n\u003cth\u003eDescription\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eOrderable Part Number\u003c\/td\u003e\n\u003ctd\u003e21000-16-05-00-103-03-02\u003c\/td\u003e\n\u003ctd\u003e21000 Proximity Probe Housing Assembly\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eA - Probe\u003c\/td\u003e\n\u003ctd\u003e16\u003c\/td\u003e\n\u003ctd\u003e3300 XL 8 mm probe\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eB - Probe Cable Length\u003c\/td\u003e\n\u003ctd\u003e05\u003c\/td\u003e\n\u003ctd\u003e0.5 m (20 in)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eC - Standoff Adapter\u003c\/td\u003e\n\u003ctd\u003e00\u003c\/td\u003e\n\u003ctd\u003eNo standoff adapter\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eD - Probe Penetration\u003c\/td\u003e\n\u003ctd\u003e103\u003c\/td\u003e\n\u003ctd\u003e10.3 in (261.6 mm) penetration\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eE - Fittings\u003c\/td\u003e\n\u003ctd\u003e03\u003c\/td\u003e\n\u003ctd\u003eOne cable seal grip with grommets\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eF - Mounting Thread\u003c\/td\u003e\n\u003ctd\u003e02\u003c\/td\u003e\n\u003ctd\u003e3\/4-14 NPT\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003eParameter\u003c\/th\u003e\n\u003cth\u003eSpecification\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eManufacturer\u003c\/td\u003e\n\u003ctd\u003eBently Nevada (Baker Hughes)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSeries\u003c\/td\u003e\n\u003ctd\u003e21000 Proximity Probe Housing Assembly\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBody Material\u003c\/td\u003e\n\u003ctd\u003eAluminum with 304 stainless steel sleeve\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMounting Thread\u003c\/td\u003e\n\u003ctd\u003e3\/4-14 NPT\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProbe Type\u003c\/td\u003e\n\u003ctd\u003e3300 XL 8 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temperature\u003c\/td\u003e\n\u003ctd\u003e-51 degC to +177 degC (-60 degF to +351 degF)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e1.1 kg (2.4 lb) typical\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEnclosure Rating\u003c\/td\u003e\n\u003ctd\u003eIP rated (refer to assembly seals)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\n\u003ch3\u003eInstallation Guidelines\u003c\/h3\u003e\n\u003cp\u003eEnsure the probe cable is longer than the internal sleeve length. For probe penetration depths exceeding 300 mm (12 in), additional sleeve support is required to prevent resonance. When installing, verify the probe gap settings as specified in the transducer system documentation. Ensure all thread engagements are properly sealed if required by the specific hazardous area classification of the installation site.\u003c\/p\u003e","brand":"Bently Nevada","offers":[{"title":"Default Title","offer_id":52666765050219,"sku":"21000-16-05-00-103-03-02","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/3227\/0443\/files\/bently-nevada-21000-16-05-00-103-03-02-proximity-probe-housingassemblies-vjxesds2o3f_e9923d0d-08d7-4430-8d4c-0cd55feea7e9.jpg?v=1765447208","url":"https:\/\/www.plcprotech.com\/products\/bently-nevada-21000-16-05-00-103-03-02-proximity-probe-housing-assembly","provider":"PLC ProTech Ltd.","version":"1.0","type":"link"}