{"product_id":"bently-nevada-21000-16-05-15-038-04-02-proximity-probe-housing-assembly","title":"Bently Nevada 21000-16-05-15-038-04-02 Proximity Probe Housing Assembly","description":"\u003ch3\u003eDescription\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003e21000-16-05-15-038-04-02\u003c\/strong\u003e: Proximity probe housing assembly designed for secure mounting and environmental protection of proximity transducer systems in industrial machinery monitoring applications. This assembly serves as the interface for probe installation, providing strain relief and protection against environmental contaminants for the connection between the proximity probe and the extension cable.\u003c\/p\u003e\n\n\u003cp\u003eThe 21000 series housings are utilized to house the probe connector and the extension cable connector, ensuring a stable, protected junction. This specific configuration utilizes the 16 mounting thread style and is compatible with defined probe diameters and cable lengths to ensure appropriate fitment and signal integrity for vibration and position measurement chains.\u003c\/p\u003e\n\n\u003ch3\u003eFeatures\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eOption 16: Mounting configuration for standard probe alignment\u003c\/li\u003e\n\u003cli\u003eOption 05: Housing geometry designed for specific probe diameter compatibility\u003c\/li\u003e\n\u003cli\u003eOption 15: Housing internal volume for designated cable length accommodation\u003c\/li\u003e\n\u003cli\u003eOption 038: Case configuration suited for installation in restricted space environments\u003c\/li\u003e\n\u003cli\u003eOption 04: Connector interface protection standard\u003c\/li\u003e\n\u003cli\u003eOption 02: Agency approval and hazardous area compliance rating\u003c\/li\u003e\n\u003cli\u003eProvides mechanical isolation and moisture protection for the probe-to-cable connection\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eApplications\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003ePower generation equipment (turbines, generators)\u003c\/li\u003e\n\u003cli\u003eOil and gas refinery rotating machinery\u003c\/li\u003e\n\u003cli\u003ePetrochemical processing compressors and pumps\u003c\/li\u003e\n\u003cli\u003eWater treatment plant high-speed centrifugal machinery\u003c\/li\u003e\n\u003cli\u003eIndustrial motor and gearbox vibration monitoring\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eOrdering Information\u003c\/h3\u003e\n\u003ctable\u003e\n\u003ctr\u003e\n\u003cth\u003eOption\u003c\/th\u003e\n\u003cth\u003eCode\u003c\/th\u003e\n\u003cth\u003eDescription\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOrderable Part Number\u003c\/td\u003e\n\u003ctd\u003e21000-16-05-15-038-04-02\u003c\/td\u003e\n\u003ctd\u003eProximity Probe Housing Assembly\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eA - Mounting Thread\u003c\/td\u003e\n\u003ctd\u003e16\u003c\/td\u003e\n\u003ctd\u003eRefer to datasheet for specific thread\/mounting pitch\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eB - Probe Size\u003c\/td\u003e\n\u003ctd\u003e05\u003c\/td\u003e\n\u003ctd\u003eStandard probe size compatibility\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eC - Cable Length\u003c\/td\u003e\n\u003ctd\u003e15\u003c\/td\u003e\n\u003ctd\u003eStandard internal cable capacity\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eD - Case Length\u003c\/td\u003e\n\u003ctd\u003e038\u003c\/td\u003e\n\u003ctd\u003eRefer to datasheet for housing depth\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eE - Connector Type\u003c\/td\u003e\n\u003ctd\u003e04\u003c\/td\u003e\n\u003ctd\u003eStandard connector protection\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eF - Agency Approval\u003c\/td\u003e\n\u003ctd\u003e02\u003c\/td\u003e\n\u003ctd\u003eStandard agency certification\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\n\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003ctable\u003e\n\u003ctr\u003e\n\u003ctd\u003eManufacturer\u003c\/td\u003e\n\u003ctd\u003eBently Nevada\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePart Number\u003c\/td\u003e\n\u003ctd\u003e21000-16-05-15-038-04-02\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHousing Type\u003c\/td\u003e\n\u003ctd\u003eProximity Probe Housing Assembly\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMounting\u003c\/td\u003e\n\u003ctd\u003eRefer to site installation requirements\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temperature\u003c\/td\u003e\n\u003ctd\u003eSubject to probe and cable environmental limits\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMaterial\u003c\/td\u003e\n\u003ctd\u003eCorrosion resistant industrial grade\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\n\n\u003ch3\u003eInstallation Guidelines\u003c\/h3\u003e\n\u003cp\u003eEnsure the housing is mounted to a vibration-free surface where possible to prevent false signal inputs. Maintain proper grounding practices as outlined in the Bently Nevada 3300 system manuals. Route cables through conduit to provide additional mechanical protection. Ensure O-rings and seals are seated correctly to maintain the IP rating of the enclosure against oil and moisture ingress.\u003c\/p\u003e","brand":"Bently Nevada","offers":[{"title":"Default Title","offer_id":52666763411819,"sku":"21000-16-05-15-038-04-02","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/3227\/0443\/files\/bently-nevada-21000-16-05-15-038-04-02-proximity-probe-housingassemblies-qykwd2sts4v_329f92fd-f2f5-4e8b-9547-df6360d58b76.jpg?v=1765447170","url":"https:\/\/www.plcprotech.com\/products\/bently-nevada-21000-16-05-15-038-04-02-proximity-probe-housing-assembly","provider":"PLC ProTech Ltd.","version":"1.0","type":"link"}