{"product_id":"bently-nevada-21504-04-36-10-02-7200-series-5-mm-and-8-mm-standard-mount-probe","title":"Bently Nevada 21504-04-36-10-02 7200 Series 5 mm and 8 mm Standard Mount Probe","description":"\u003ch3\u003eDescription\u003c\/h3\u003e\n\u003cp\u003eThe \u003cstrong\u003e21504-04-36-10-02\u003c\/strong\u003e is an 8 mm standard mount proximity probe from the Bently Nevada 7200 series, configured with 0.4 inches of unthreaded length (Option 04), 3.6 inches of case length (Option 36), a 1.0 metre total cable length (Option 10), and a miniature male coaxial connector (Option 02). As a non-contacting, eddy-current transducer, it is engineered to measure static and dynamic distances between the probe tip and the observed target, such as a machine shaft.\u003c\/p\u003e\n\n\u003cp\u003eThis 8 mm probe is constructed from polyphenylene sulfide (PPS), a durable material suitable for harsh, wet, or chemically aggressive industrial environments. It provides a linear measuring range of 80 mils (2 mm) with a scale factor of 200 mV\/mil. This configuration is widely used for radial vibration, axial thrust position, and shaft average radial position measurements in critical rotating machinery, including steam turbines, compressors, pumps, and electric motors.\u003c\/p\u003e\n\n\u003ch3\u003eFeatures\u003c\/h3\u003e\n\u003cul\u003e\n    \u003cli\u003e\n\u003cstrong\u003eProbe Diameter:\u003c\/strong\u003e 8 mm for standard mount configuration\u003c\/li\u003e\n    \u003cli\u003e\n\u003cstrong\u003eUnthreaded Length:\u003c\/strong\u003e 0.4 inches (Option 04)\u003c\/li\u003e\n    \u003cli\u003e\n\u003cstrong\u003eCase Length:\u003c\/strong\u003e 3.6 inches (Option 36)\u003c\/li\u003e\n    \u003cli\u003e\n\u003cstrong\u003eCable Length:\u003c\/strong\u003e 1.0 metre (Option 10)\u003c\/li\u003e\n    \u003cli\u003e\n\u003cstrong\u003eConnector Type:\u003c\/strong\u003e Miniature male coaxial connector (Option 02)\u003c\/li\u003e\n    \u003cli\u003e\n\u003cstrong\u003eConstruction:\u003c\/strong\u003e Polyphenylene sulfide (PPS) probe tip for chemical and environmental resistance\u003c\/li\u003e\n    \u003cli\u003e\n\u003cstrong\u003eCompatibility:\u003c\/strong\u003e Compatible with 7200 series Proximitor sensors and 3300\/9000 Monitoring Systems\u003c\/li\u003e\n    \u003cli\u003e\n\u003cstrong\u003eThread Configuration:\u003c\/strong\u003e 3\/8-24 UNF-2A standard mount\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eApplications\u003c\/h3\u003e\n\u003cul\u003e\n    \u003cli\u003eRadial vibration monitoring to indicate bearing condition\u003c\/li\u003e\n    \u003cli\u003eAxial thrust position measurements to detect bearing wear\u003c\/li\u003e\n    \u003cli\u003eShaft average radial position for rotor stability analysis\u003c\/li\u003e\n    \u003cli\u003eVibration amplitude and phase angle plotting for diagnostic formats\u003c\/li\u003e\n    \u003cli\u003eEccentricity measurement to identify rotor bow\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eOrdering Information\u003c\/h3\u003e\n\u003ctable\u003e\n    \u003ctr\u003e\n        \u003cth\u003eOption\u003c\/th\u003e\n        \u003cth\u003eCode on This SKU\u003c\/th\u003e\n        \u003cth\u003eDescription\u003c\/th\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n        \u003ctd\u003eOrderable Part Number\u003c\/td\u003e\n        \u003ctd\u003e21504-04-36-10-02\u003c\/td\u003e\n        \u003ctd\u003e7200 8 mm Standard Mount Probe\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n        \u003ctd\u003eA - Unthreaded Length\u003c\/td\u003e\n        \u003ctd\u003e04\u003c\/td\u003e\n        \u003ctd\u003e0.4 inches\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n        \u003ctd\u003eB - Case Length\u003c\/td\u003e\n        \u003ctd\u003e36\u003c\/td\u003e\n        \u003ctd\u003e3.6 inches\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n        \u003ctd\u003eC - Total Cable Length\u003c\/td\u003e\n        \u003ctd\u003e10\u003c\/td\u003e\n        \u003ctd\u003e1.0 metre\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n        \u003ctd\u003eD - Connector\u003c\/td\u003e\n        \u003ctd\u003e02\u003c\/td\u003e\n        \u003ctd\u003eWith miniature male coaxial connector\u003c\/td\u003e\n    \u003c\/tr\u003e\n\u003c\/table\u003e\n\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003ctable\u003e\n    \u003ctr\u003e\n        \u003ctd\u003eManufacturer\u003c\/td\u003e\n        \u003ctd\u003eBently Nevada (Baker Hughes)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n        \u003ctd\u003ePart Number\u003c\/td\u003e\n        \u003ctd\u003e21504-04-36-10-02\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n        \u003ctd\u003eProbe Diameter\u003c\/td\u003e\n        \u003ctd\u003e8 mm\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n        \u003ctd\u003eThread\u003c\/td\u003e\n        \u003ctd\u003e3\/8-24 UNF-2A\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n        \u003ctd\u003eLinear Range\u003c\/td\u003e\n        \u003ctd\u003e80 mils (2.0 mm)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n        \u003ctd\u003eScale Factor\u003c\/td\u003e\n        \u003ctd\u003e200 mV\/mil (7.87 V\/mm)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n        \u003ctd\u003eFrequency Response\u003c\/td\u003e\n        \u003ctd\u003e0 Hz to 10 kHz\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n        \u003ctd\u003eOperating Temperature\u003c\/td\u003e\n        \u003ctd\u003e-30 degF to +350 degF (-34 degC to +177 degC)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n        \u003ctd\u003eMaterial\u003c\/td\u003e\n        \u003ctd\u003ePolyphenylene sulfide (PPS)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n        \u003ctd\u003eRelative Humidity\u003c\/td\u003e\n        \u003ctd\u003eTo 95%, noncondensing\u003c\/td\u003e\n    \u003c\/tr\u003e\n\u003c\/table\u003e\n\n\u003ch3\u003eInstallation Guidelines\u003c\/h3\u003e\n\u003cp\u003eEnsure the probe is mounted securely using the provided jam nut. Maintain the appropriate gap distance to stay within the linear operating range. When routing the coaxial cable, avoid sharp bends and protect the connector from moisture and contaminants. This system should be calibrated as a complete loop (probe, extension cable, and Proximitor) for optimal accuracy.\u003c\/p\u003e","brand":"Bently Nevada","offers":[{"title":"Default Title","offer_id":52666568737131,"sku":"21504-04-36-10-02","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/3227\/0443\/files\/bently-nevada-21504-04-36-10-02-proximity-probe-jt4shuz5xvo_6c502a5e-0825-4e8c-a24d-bb0c5eb47d48.jpg?v=1765440794","url":"https:\/\/www.plcprotech.com\/products\/bently-nevada-21504-04-36-10-02-7200-series-5-mm-and-8-mm-standard-mount-probe","provider":"PLC ProTech Ltd.","version":"1.0","type":"link"}