{"product_id":"bently-nevada-21747-085-01-7200-series-extension-cable","title":"Bently Nevada 21747-085-01 7200 Series Extension Cable","description":"\u003ch3\u003eDescription\u003c\/h3\u003e\n\u003cstrong\u003e21747-085-01\u003c\/strong\u003e: 7200 Series extension cable with 8.5 m total length and stainless steel armor (Option 01). This cable is designed for use in 7200 proximity transducer systems to connect the proximity probe to the Proximitor sensor. It maintains the signal integrity required for shaft vibration and axial position measurements on rotating machinery such as turbines, compressors, and pumps.\n\nThe extension cable serves as the intermediate link in the 7200 system, ensuring that the Proximitor can be mounted at a distance from the machine while maintaining calibration accuracy. This specific configuration features integrated stainless steel armor, which provides additional mechanical protection against abrasion and physical damage in harsh industrial environments.\n\n\u003ch3\u003eFeatures\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eTotal Cable Length: 8.5 m\u003c\/li\u003e\n\u003cli\u003eArmor: Stainless steel armor (Option 01) for improved resistance to physical abuse\u003c\/li\u003e\n\u003cli\u003eCompatibility: Designed for use with 7200 Series proximity probes and Proximitor sensors\u003c\/li\u003e\n\u003cli\u003eEnvironmental: Suitable for use in confined spaces and demanding industrial conditions\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eApplications\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eRadial vibration monitoring for bearing condition and machine malfunction diagnostics\u003c\/li\u003e\n\u003cli\u003eAxial thrust position measurement to detect bearing wear\u003c\/li\u003e\n\u003cli\u003eShaft average radial position determination for rotor stability analysis\u003c\/li\u003e\n\u003cli\u003eGeneral purpose displacement measurements on steam\/gas turbines, electric motors, and pumps\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eOrdering Information\u003c\/h3\u003e\n\u003ctable\u003e\n  \u003ctr\u003e\n    \u003cth\u003eOption\u003c\/th\u003e\n    \u003cth\u003eCode on This SKU\u003c\/th\u003e\n    \u003cth\u003eDescription\u003c\/th\u003e\n  \u003c\/tr\u003e\n  \u003ctr\u003e\n    \u003ctd\u003eOrderable Part Number\u003c\/td\u003e\n    \u003ctd\u003e21747-085-01\u003c\/td\u003e\n    \u003ctd\u003e7200 Series Extension Cable\u003c\/td\u003e\n  \u003c\/tr\u003e\n  \u003ctr\u003e\n    \u003ctd\u003eA - Cable Length\u003c\/td\u003e\n    \u003ctd\u003e085\u003c\/td\u003e\n    \u003ctd\u003e8.5 m (335 inches)\u003c\/td\u003e\n  \u003c\/tr\u003e\n  \u003ctr\u003e\n    \u003ctd\u003eB - Armor\u003c\/td\u003e\n    \u003ctd\u003e01\u003c\/td\u003e\n    \u003ctd\u003eWith stainless steel armor\u003c\/td\u003e\n  \u003c\/tr\u003e\n\u003c\/table\u003e\n\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003ctable\u003e\n  \u003ctr\u003e\n    \u003cth\u003eParameter\u003c\/th\u003e\n    \u003cth\u003eSpecification\u003c\/th\u003e\n  \u003c\/tr\u003e\n  \u003ctr\u003e\n    \u003ctd\u003eManufacturer\u003c\/td\u003e\n    \u003ctd\u003eBently Nevada\u003c\/td\u003e\n  \u003c\/tr\u003e\n  \u003ctr\u003e\n    \u003ctd\u003ePart Number\u003c\/td\u003e\n    \u003ctd\u003e21747-085-01\u003c\/td\u003e\n    \u003ctd\u003e\n  \u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n    \u003ctd\u003eCable Length\u003c\/td\u003e\n    \u003ctd\u003e8.5 m\u003c\/td\u003e\n  \u003c\/tr\u003e\n  \u003ctr\u003e\n    \u003ctd\u003eArmor Type\u003c\/td\u003e\n    \u003ctd\u003eStainless Steel\u003c\/td\u003e\n  \u003c\/tr\u003e\n  \u003ctr\u003e\n    \u003ctd\u003eSeries\u003c\/td\u003e\n    \u003ctd\u003e7200\u003c\/td\u003e\n  \u003c\/tr\u003e\n  \u003ctr\u003e\n    \u003ctd\u003eOperating Temperature\u003c\/td\u003e\n    \u003ctd\u003e-34 degC to +177 degC\u003c\/td\u003e\n  \u003c\/tr\u003e\n  \u003ctr\u003e\n    \u003ctd\u003eCompatibility\u003c\/td\u003e\n    \u003ctd\u003e7200 Proximity Transducer Systems\u003c\/td\u003e\n  \u003c\/tr\u003e\n\u003c\/table\u003e\n\n\u003ch3\u003eInstallation Guidelines\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eEnsure proper routing of the coaxial cable to avoid excessive bending, which may damage the conductor or shielding.\u003c\/li\u003e\n\u003cli\u003eThe extension cable should be securely fastened to prevent vibration-induced wear or loosening of connectors.\u003c\/li\u003e\n\u003cli\u003eEnsure all connectors are clean and free of moisture or oil before installation to prevent signal degradation.\u003c\/li\u003e\n\u003cli\u003eMaintain adequate separation from high-voltage power cables to minimize electromagnetic interference (EMI) on the signal path.\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Bently Nevada","offers":[{"title":"Default Title","offer_id":52666636042603,"sku":"21747-085-01","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/3227\/0443\/files\/bently-nevada-21747-085-01-proximitor-probe-extension-cable-npy3uvlqbjm_af48ecc2-a50a-45a6-83f9-0b8a3e7d09e0.jpg?v=1765444472","url":"https:\/\/www.plcprotech.com\/products\/bently-nevada-21747-085-01-7200-series-extension-cable","provider":"PLC ProTech Ltd.","version":"1.0","type":"link"}