{"product_id":"bently-nevada-31000-16-10-15-201-02-02-english-proximity-probe-housing-assemblies","title":"Bently Nevada 31000-16-10-15-201-02-02 English Proximity Probe Housing Assemblies","description":"\u003ch3\u003eDescription\u003c\/h3\u003e\n\u003cp\u003eThe \u003cstrong\u003e31000-16-10-15-201-02-02\u003c\/strong\u003e is an English proximity probe housing assembly configured with a 3300 XL 8 mm proximity probe (Option 16), 1.0 m probe cable length (Option 10), 1.5 inch standoff adapter length (Option 15), 20.1 inch probe penetration depth (Option 201), two 3\/4-14 NPT fittings with one plug (Option 02), and 3\/4-14 NPT mounting threads (Option 02). This assembly is part of the Bently Nevada 31000 series, specifically engineered to provide robust mechanical and environmental protection for proximity probes mounted through machinery cases.\u003c\/p\u003e\n\n\u003cp\u003eUsed primarily for radial vibration and Keyphasor measurements, this housing assembly allows for external access to the probe and its extension cable. This design facilitates efficient gap adjustment and probe replacement without requiring the disassembly of the machine case. Constructed from polyphenylene sulfide (PPS) and corrosion-resistant stainless steel, the 31000 series adheres to API 670 standards for externally mounted proximity probe housings and is suitable for use in hazardous area applications when installed with appropriate I.S. barriers and transducer systems.\u003c\/p\u003e\n\n\u003ch3\u003eFeatures\u003c\/h3\u003e\n\u003cul\u003e\n    \u003cli\u003e\n\u003cstrong\u003eProbe Configuration:\u003c\/strong\u003e Includes factory-installed 3300 XL 8 mm proximity probe for high-accuracy vibration and position monitoring.\u003c\/li\u003e\n    \u003cli\u003e\n\u003cstrong\u003eHousing Material:\u003c\/strong\u003e High-strength, corrosion-resistant polyphenylene sulfide (PPS) body with stainless steel components.\u003c\/li\u003e\n    \u003cli\u003e\n\u003cstrong\u003eExternal Access:\u003c\/strong\u003e Simplifies maintenance by allowing probe gap adjustment and replacement from outside the machine case.\u003c\/li\u003e\n    \u003cli\u003e\n\u003cstrong\u003eAPI 670 Compliance:\u003c\/strong\u003e Fully compliant with American Petroleum Institute standards for externally mounted probe housings.\u003c\/li\u003e\n    \u003cli\u003e\n\u003cstrong\u003eFittings:\u003c\/strong\u003e Equipped with two 3\/4-14 NPT conduit fittings and one plug for secure, flexible cable routing.\u003c\/li\u003e\n    \u003cli\u003e\n\u003cstrong\u003eMounting:\u003c\/strong\u003e 3\/4-14 NPT mounting thread option for standard machinery case interface.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eApplications\u003c\/h3\u003e\n\u003cul\u003e\n    \u003cli\u003eRadial vibration monitoring for rotating machinery\u003c\/li\u003e\n    \u003cli\u003eKeyphasor and speed measurements\u003c\/li\u003e\n    \u003cli\u003eAxial position measurement (when used in approved configurations)\u003c\/li\u003e\n    \u003cli\u003eHazardous area applications (when paired with appropriate I.S. barriers)\u003c\/li\u003e\n    \u003cli\u003eOil and gas, petrochemical, and power generation machinery protection\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eOrdering Information\u003c\/h3\u003e\n\u003ctable\u003e\n    \u003ctr\u003e\n        \u003cth\u003eOption\u003c\/th\u003e\n        \u003cth\u003eCode on This SKU\u003c\/th\u003e\n        \u003cth\u003eDescription\u003c\/th\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n        \u003ctd\u003eOrderable Part Number\u003c\/td\u003e\n        \u003ctd\u003e31000-16-10-15-201-02-02\u003c\/td\u003e\n        \u003ctd\u003e31000 English Proximity Probe Housing Assembly\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n        \u003ctd\u003eA - Probe with Connector\u003c\/td\u003e\n        \u003ctd\u003e16\u003c\/td\u003e\n        \u003ctd\u003e3300 XL 8 mm probe\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n        \u003ctd\u003eB - Probe Cable Length\u003c\/td\u003e\n        \u003ctd\u003e10\u003c\/td\u003e\n        \u003ctd\u003e1.0 m (39 in) cable\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n        \u003ctd\u003eC - Standoff Adapter Length\u003c\/td\u003e\n        \u003ctd\u003e15\u003c\/td\u003e\n        \u003ctd\u003e1.5 in (38 mm)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n        \u003ctd\u003eD - Probe Penetration\u003c\/td\u003e\n        \u003ctd\u003e201\u003c\/td\u003e\n        \u003ctd\u003e20.1 in (511 mm)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n        \u003ctd\u003eE - Fittings\u003c\/td\u003e\n        \u003ctd\u003e02\u003c\/td\u003e\n        \u003ctd\u003eTwo 3\/4-14 NPT fittings, one plug\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n        \u003ctd\u003eF - Mounting Thread\u003c\/td\u003e\n        \u003ctd\u003e02\u003c\/td\u003e\n        \u003ctd\u003e3\/4-14 NPT\u003c\/td\u003e\n    \u003c\/tr\u003e\n\u003c\/table\u003e\n\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003ctable\u003e\n    \u003ctr\u003e\n        \u003cth\u003eParameter\u003c\/th\u003e\n        \u003cth\u003eSpecification\u003c\/th\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n        \u003ctd\u003eManufacturer\u003c\/td\u003e\n        \u003ctd\u003eBently Nevada (Baker Hughes)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n        \u003ctd\u003ePart Number\u003c\/td\u003e\n        \u003ctd\u003e31000-16-10-15-201-02-02\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n        \u003ctd\u003eHousing Material\u003c\/td\u003e\n        \u003ctd\u003ePolyphenylene sulfide (PPS) and Stainless Steel\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n        \u003ctd\u003eProbe Type\u003c\/td\u003e\n        \u003ctd\u003e3300 XL 8 mm\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n        \u003ctd\u003eCable Length\u003c\/td\u003e\n        \u003ctd\u003e1.0 m\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n        \u003ctd\u003eStandoff Adapter Length\u003c\/td\u003e\n        \u003ctd\u003e1.5 in\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n        \u003ctd\u003eProbe Penetration\u003c\/td\u003e\n        \u003ctd\u003e20.1 in\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n        \u003ctd\u003eMounting Thread\u003c\/td\u003e\n        \u003ctd\u003e3\/4-14 NPT\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n        \u003ctd\u003eFittings\u003c\/td\u003e\n        \u003ctd\u003eTwo 3\/4-14 NPT fittings, one plug\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n        \u003ctd\u003eStandards Compliance\u003c\/td\u003e\n        \u003ctd\u003eAPI 670\u003c\/td\u003e\n    \u003c\/tr\u003e\n\u003c\/table\u003e\n\n\u003ch3\u003eInstallation Guidelines\u003c\/h3\u003e\n\u003cp\u003eEnsure the outer sleeve is correctly installed into the machine case before fitting the housing assembly. When adjusting the probe gap, verify the probe tip remains clear of the target material. Use the provided conduit fittings and plugs to seal unused ports to maintain the integrity of the enclosure. For sleeve lengths exceeding 305 mm (12 in), it is recommended to use a probe support or oil seal to prevent resonance. Always verify that all retainer nuts and housing cover screws are tightened to the specified torque after final calibration.\u003c\/p\u003e","brand":"Bently Nevada","offers":[{"title":"Default Title","offer_id":52666767704427,"sku":"31000-16-10-15-201-02-02","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/3227\/0443\/files\/bently-nevada-31000-16-10-15-201-02-02-proximity-probe-housingassemblies-vdrnquozb1n_e8407d0a-4df5-4519-beab-a9cd25b95b84.jpg?v=1765447234","url":"https:\/\/www.plcprotech.com\/products\/bently-nevada-31000-16-10-15-201-02-02-english-proximity-probe-housing-assemblies","provider":"PLC ProTech Ltd.","version":"1.0","type":"link"}