{"product_id":"bently-nevada-3300-16-dual-xy-rv-vibration-monitor","title":"Bently Nevada 3300\/16 Dual XY\/RV Vibration Monitor","description":"\u003cp\u003e\u003cspan class=\"citation-826\"\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003c\/span\u003e\u003cstrong\u003eBently Nevada 3300\/16\u003c\/strong\u003e\u003cspan class=\"citation-826\"\u003e\u003cspan\u003e \u003c\/span\u003eis a dual-channel vibration monitor from the legacy\u003cspan\u003e \u003c\/span\u003e\u003c\/span\u003e\u003cstrong\u003e3300 Monitoring System\u003c\/strong\u003e\u003cspan class=\"citation-826 citation-end-826\"\u003e.\u003csup class=\"superscript\"\u003e\u003c\/sup\u003e\u003c\/span\u003e\u003cspan\u003e \u003c\/span\u003eIt is designed to provide continuous, online protection for rotating machinery by measuring radial vibration (RV) or XY shaft orbit. This module is essential for monitoring the mechanical health of centrifugal compressors, pumps, and motors.\u003c\/p\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003ch4\u003e1. Input\u003c\/h4\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan class=\"citation-825\"\u003e\u003c\/span\u003e\u003cstrong\u003eTransducer Type:\u003c\/strong\u003e\u003cspan class=\"citation-825\"\u003e\u003cspan\u003e \u003c\/span\u003eAccepts signals from Bently Nevada\u003cspan\u003e \u003c\/span\u003e\u003c\/span\u003e\u003cstrong\u003eProximitor\u003c\/strong\u003e\u003cspan class=\"citation-825 citation-end-825\"\u003e\u003cspan\u003e \u003c\/span\u003eTransducer systems (non-contacting proximity probes).\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eSensitivity:\u003c\/strong\u003e\u003cspan class=\"citation-824\"\u003e\u003cspan\u003e \u003c\/span\u003eUser-programmable for\u003cspan\u003e \u003c\/span\u003e\u003c\/span\u003e\u003cstrong\u003e200 mV\/mil\u003c\/strong\u003e\u003cspan class=\"citation-824\"\u003e\u003cspan\u003e \u003c\/span\u003e(8 V\/mm) or\u003cspan\u003e \u003c\/span\u003e\u003c\/span\u003e\u003cstrong\u003e100 mV\/mil\u003c\/strong\u003e\u003cspan class=\"citation-824 citation-end-824\"\u003e\u003cspan\u003e \u003c\/span\u003e(4 V\/mm).\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan class=\"citation-823\"\u003e\u003c\/span\u003e\u003cstrong\u003eInput Impedance:\u003c\/strong\u003e\u003cspan class=\"citation-823 citation-end-823\"\u003e\u003cspan\u003e \u003c\/span\u003e10 kOhm.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4\u003e2. Signal Conditioning\u003c\/h4\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eFrequency Response:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e4 Hz to 4.2 kHz (240 cpm to 252,000 cpm) for standard applications.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eAccuracy:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eWithin ±0.33% of full-scale at room temperature.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan class=\"citation-822\"\u003e\u003c\/span\u003e\u003cstrong\u003ePeak-to-Peak Measurement:\u003c\/strong\u003e\u003cspan class=\"citation-822 citation-end-822\"\u003e\u003cspan\u003e \u003c\/span\u003eMonitors the overall vibration displacement in mils or micrometers.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4\u003e3. Outputs\u003c\/h4\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eRecorder Outputs:\u003c\/strong\u003e\u003cspan class=\"citation-821\"\u003e\u003cspan\u003e \u003c\/span\u003eUser-programmable for\u003cspan\u003e \u003c\/span\u003e\u003c\/span\u003e\u003cstrong\u003e+4 to +20 mA\u003c\/strong\u003e\u003cspan class=\"citation-821\"\u003e,\u003cspan\u003e \u003c\/span\u003e\u003c\/span\u003e\u003cstrong\u003e0 to -10 Vdc\u003c\/strong\u003e\u003cspan class=\"citation-821\"\u003e, or\u003cspan\u003e \u003c\/span\u003e\u003c\/span\u003e\u003cstrong\u003e+1 to +5 Vdc\u003c\/strong\u003e\u003cspan class=\"citation-821 citation-end-821\"\u003e.\u003csup class=\"superscript\"\u003e\u003c\/sup\u003e\u003c\/span\u003e\u003cspan\u003e \u003c\/span\u003eOutputs are proportional to the full-scale range.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan class=\"citation-820\"\u003e\u003c\/span\u003e\u003cstrong\u003eBuffered Transducer Outputs:\u003c\/strong\u003e\u003cspan class=\"citation-820 citation-end-820\"\u003e\u003cspan\u003e \u003c\/span\u003eAvailable via front panel coaxial connectors and rear terminal blocks.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eOutput Impedance:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e100 Ohm (for voltage outputs).\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4\u003e4. Alarms \u0026amp; Displays\u003c\/h4\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eDisplays:\u003c\/strong\u003e\u003cspan class=\"citation-819 citation-end-819\"\u003e\u003cspan\u003e \u003c\/span\u003eDual vertical LCD bargraphs (one per channel).\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eAlarm Setpoints:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eAlert and Danger levels are digitally adjustable from 0 to 100% of full-scale.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eOK LED:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eMonitors the integrity of the probe, cable, and internal circuitry.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr\u003e\n\u003ch3\u003eOrdering Information (Suffix Codes)\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eOrder Format: 3300\/16-AXX-BXX-CXX-DXX-EXX\u003c\/strong\u003e\u003c\/p\u003e\n\u003ch4\u003e\u003cstrong\u003eA: Full-scale Range Option\u003c\/strong\u003e\u003c\/h4\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003e01\u003c\/strong\u003e: 0-3 mils (peak-to-peak)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003e02\u003c\/strong\u003e: 0-5 mils\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003e03\u003c\/strong\u003e: 0-10 mils\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003e04\u003c\/strong\u003e: 0-15 mils\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003e06\u003c\/strong\u003e: 0-100 µm\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003e07\u003c\/strong\u003e: 0-150 µm\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003e08\u003c\/strong\u003e: 0-200 µm\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003e09\u003c\/strong\u003e: 0-250 µm\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4\u003e\u003cstrong\u003eB: Transducer Input Option\u003c\/strong\u003e\u003c\/h4\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003e01\u003c\/strong\u003e: 3300 or 7200 Proximitor system (200 mV\/mil)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003e02\u003c\/strong\u003e: 7200 11 mm Proximitor system (100 mV\/mil)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003e03\u003c\/strong\u003e: 7200 14 mm Proximitor system (100 mV\/mil)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003e05\u003c\/strong\u003e: 3300XL NSv and 3300 RAM (200 mV\/mil)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4\u003e\u003cstrong\u003eC: Alarm Relay Option\u003c\/strong\u003e\u003c\/h4\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003e00\u003c\/strong\u003e: No Relays\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan class=\"citation-818\"\u003e\u003c\/span\u003e\u003cstrong\u003e01\u003c\/strong\u003e\u003cspan class=\"citation-818 citation-end-818\"\u003e: Epoxy-sealed\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan class=\"citation-817\"\u003e\u003c\/span\u003e\u003cstrong\u003e02\u003c\/strong\u003e\u003cspan class=\"citation-817 citation-end-817\"\u003e: Hermetically-sealed\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003e03\u003c\/strong\u003e: Quad Relay (Epoxy-sealed only)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003e04\u003c\/strong\u003e: Spare Monitor - No SIM\/SIRM\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4\u003e\u003cstrong\u003eD: Agency Approval Option\u003c\/strong\u003e\u003c\/h4\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003e00\u003c\/strong\u003e: Not required\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003e01\u003c\/strong\u003e: CSA\/NRTL\/C\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan class=\"citation-816\"\u003e\u003c\/span\u003e\u003cstrong\u003e02\u003c\/strong\u003e\u003cspan class=\"citation-816 citation-end-816\"\u003e: ATEX self-certification\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4\u003e\u003cstrong\u003eE: Safety Barrier Option\u003c\/strong\u003e\u003c\/h4\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003e00\u003c\/strong\u003e: None\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003e01\u003c\/strong\u003e: External\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003e02\u003c\/strong\u003e: Internal\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr\u003e\n\u003ch3\u003eEngineering \u0026amp; Installation Guide\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eXY Configuration:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eIn XY monitoring, two probes are mounted 90 degrees apart on the same bearing.\u003cspan\u003e \u003c\/span\u003e\u003cspan class=\"citation-815 citation-end-815\"\u003eThe 3300\/16 processes these inputs to provide a comprehensive view of the shaft's radial movement (orbit).\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eRelay Voting:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eThe monitor is typically configured for\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eOR voting\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e(Danger relay actuates if either channel reaches the setpoint) for radial vibration, unlike thrust monitors which often use AND voting.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eGrounding:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eTo prevent interference, ensure the shield of the extension cable is grounded at the monitor end only. Never ground the shield at the Proximitor housing.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eMaintenance:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eWhen replacing a module, the \"Bypass\" switch must be used to inhibit the relays and prevent a false machine trip.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Bently Nevada","offers":[{"title":"Default Title","offer_id":52666860765547,"sku":"3300\/16","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/3227\/0443\/files\/bently-nevada-3300-16-dual-vibration-monitor-5zzrar1f3x1_a92c3e62-5038-4339-887c-ef3cde16ad1f.jpg?v=1765449289","url":"https:\/\/www.plcprotech.com\/products\/bently-nevada-3300-16-dual-xy-rv-vibration-monitor","provider":"PLC ProTech Ltd.","version":"1.0","type":"link"}