{"product_id":"bently-nevada-3300-30-six-channel-temperature-tc-input-monitor","title":"Bently Nevada 3300\/30 Six-Channel Temperature TC Input Monitor","description":"\u003cp\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eBently Nevada 3300\/30 Six-Channel Temperature Monitor\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eis a six-channel temperature monitoring module designed for the legacy\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eBently Nevada 3300 Monitoring System\u003c\/strong\u003e.\u003cbr\u003eThis version is specifically configured to accept\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eThermocouple (TC) inputs\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003erather than RTD sensors.\u003c\/p\u003e\n\u003cp\u003eIt is commonly used to monitor critical temperature points in industrial machinery, including:\u003c\/p\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003eBearing metal temperature\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eExhaust gas temperature\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eStator winding temperature\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eLube oil system temperature\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eThe monitor provides continuous protection through configurable alarm relays and standard recorder outputs, ensuring reliable thermal supervision in turbine, compressor, and generator applications.\u003c\/p\u003e\n\u003chr\u003e\n\u003ch2\u003eTechnical Specifications\u003c\/h2\u003e\n\u003ch3\u003e1. Inputs\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eInput Capacity\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003eSupports up to\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003esix (6) independent thermocouple inputs\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eEach channel operates independently\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eSupported Thermocouple Types\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003eType\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eJ\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e— Iron \/ Constantan\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eType\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eK\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e— Chromel \/ Alumel\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eType\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eE\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e— Chromel \/ Constantan\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eType\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eT\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e— Copper \/ Constantan\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eCold Junction Compensation\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003eInternal compensation provided at the terminal block\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eAutomatically corrects measurement drift caused by ambient temperature changes\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eEnsures stable temperature accuracy across operating environments\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr\u003e\n\u003ch3\u003e2. Signal Conditioning\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eAccuracy\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003eWithin\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e±2.2% of signal\u003c\/strong\u003e, plus thermocouple tolerance\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eReference temperature:\u003cbr\u003e\u003cstrong\u003e+25°C (+77°F)\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eOpen Thermocouple Detection\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThe monitor includes automatic fault detection when a thermocouple circuit opens.\u003c\/p\u003e\n\u003cp\u003eSelectable response modes:\u003c\/p\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eUpscale drive\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e— Forces reading to high value\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eDownscale drive\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e— Forces reading to low value\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eThis feature prevents machinery from operating without temperature protection.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eScan Rate\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003eAll six channels scanned approximately:\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003e0.5 seconds per cycle\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThis scan speed is typical for machinery protection systems where temperature changes occur gradually compared to vibration signals.\u003c\/p\u003e\n\u003chr\u003e\n\u003ch3\u003e3. Outputs\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eRecorder Outputs\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eUser-programmable analog outputs:\u003c\/p\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e+4 to +20 mA\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e0 to -10 Vdc\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e+1 to +5 Vdc\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eBuffered Outputs\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eAvailable for diagnostic and monitoring purposes:\u003c\/p\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003eFront panel coaxial connectors\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eRear terminal block connections\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eOne buffered output per channel\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eThese outputs are typically connected to:\u003c\/p\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003eDCS systems\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003ePLC systems\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eData recorders\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eCondition monitoring software\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr\u003e\n\u003ch3\u003e4. Alarms \u0026amp; Display\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eDisplay\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e7-segment LCD temperature display\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eShows real-time temperature value\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eChannel selection:\u003c\/p\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003eUse the\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eDisplay\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003ebutton\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eCycles through Channel 1 to Channel 6\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eAlarm Setpoints\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eEach channel supports independent alarm configuration:\u003c\/p\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003eAlert alarm\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eDanger alarm\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eBoth thresholds are fully adjustable.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eOK Indicator\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eOK LED\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003econtinuously monitors system health, including:\u003c\/p\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003eMonitor electronics\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eThermocouple sensors\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eField wiring integrity\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr\u003e\n\u003ch2\u003eOrdering Information\u003c\/h2\u003e\n\u003cp\u003e\u003cstrong\u003eOrder Format\u003c\/strong\u003e\u003c\/p\u003e\n\u003cpre class=\"overflow-visible! px-0!\"\u003e3300\/30-AXX-BXX-CXX-DXX-EXX\u003cbr\u003e\u003c\/pre\u003e\n\u003chr\u003e\n\u003ch3\u003eA — Full-Scale Range Option\u003c\/h3\u003e\n\u003ctable class=\"w-fit min-w-(--thread-content-width)\"\u003e\n\u003cthead\u003e\n\u003ctr class=\"firstRow\"\u003e\n\u003cth class=\"\"\u003eCode\u003c\/th\u003e\n\u003cth class=\"\"\u003eTemperature Range\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e01\u003c\/td\u003e\n\u003ctd\u003e0 to 100°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e02\u003c\/td\u003e\n\u003ctd\u003e0 to 200°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e03\u003c\/td\u003e\n\u003ctd\u003e0 to 500°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e04\u003c\/td\u003e\n\u003ctd\u003e0 to 1000°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e05\u003c\/td\u003e\n\u003ctd\u003e32 to 212°F\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e06\u003c\/td\u003e\n\u003ctd\u003e32 to 392°F\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e07\u003c\/td\u003e\n\u003ctd\u003e32 to 932°F\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e08\u003c\/td\u003e\n\u003ctd\u003e32 to 1832°F\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003chr\u003e\n\u003ch3\u003eB — Thermocouple Input Option\u003c\/h3\u003e\n\u003ctable class=\"w-fit min-w-(--thread-content-width)\"\u003e\n\u003cthead\u003e\n\u003ctr class=\"firstRow\"\u003e\n\u003cth class=\"\"\u003eCode\u003c\/th\u003e\n\u003cth class=\"\"\u003eThermocouple Type\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e01\u003c\/td\u003e\n\u003ctd\u003eType J\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e02\u003c\/td\u003e\n\u003ctd\u003eType K\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e03\u003c\/td\u003e\n\u003ctd\u003eType E\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e04\u003c\/td\u003e\n\u003ctd\u003eType T\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003chr\u003e\n\u003ch3\u003eC — Alarm Relay Option\u003c\/h3\u003e\n\u003ctable class=\"w-fit min-w-(--thread-content-width)\"\u003e\n\u003cthead\u003e\n\u003ctr class=\"firstRow\"\u003e\n\u003cth class=\"\"\u003eCode\u003c\/th\u003e\n\u003cth class=\"\"\u003eDescription\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e00\u003c\/td\u003e\n\u003ctd\u003eNo relays\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e01\u003c\/td\u003e\n\u003ctd\u003eEpoxy-sealed relay\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e02\u003c\/td\u003e\n\u003ctd\u003eHermetically-sealed relay\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003chr\u003e\n\u003ch3\u003eD — Agency Approval Option\u003c\/h3\u003e\n\u003ctable class=\"w-fit min-w-(--thread-content-width)\"\u003e\n\u003cthead\u003e\n\u003ctr class=\"firstRow\"\u003e\n\u003cth class=\"\"\u003eCode\u003c\/th\u003e\n\u003cth class=\"\"\u003eCertification\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e00\u003c\/td\u003e\n\u003ctd\u003eNot required\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e01\u003c\/td\u003e\n\u003ctd\u003eCSA \/ NRTL \/ C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e02\u003c\/td\u003e\n\u003ctd\u003eATEX self-certification\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003chr\u003e\n\u003ch3\u003eE — Safety Barrier Option\u003c\/h3\u003e\n\u003ctable class=\"w-fit min-w-(--thread-content-width)\"\u003e\n\u003cthead\u003e\n\u003ctr class=\"firstRow\"\u003e\n\u003cth class=\"\"\u003eCode\u003c\/th\u003e\n\u003cth class=\"\"\u003eDescription\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e00\u003c\/td\u003e\n\u003ctd\u003eNone\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e01\u003c\/td\u003e\n\u003ctd\u003eExternal barriers\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e02\u003c\/td\u003e\n\u003ctd\u003eInternal barriers\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003chr\u003e\n\u003ch2\u003eEngineering \u0026amp; Installation Guide\u003c\/h2\u003e\n\u003ch3\u003eSpace Requirement\u003c\/h3\u003e\n\u003cp\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e3300\/30 temperature monitor\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eis a:\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eDouble-width module\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eInstallation requirement:\u003c\/p\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003eOccupies\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003etwo (2) slots\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003ein the 3300 rack\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eThis is important when planning rack capacity in retrofit or expansion projects.\u003c\/p\u003e\n\u003chr\u003e\n\u003ch3\u003eThermocouple Lead Wire Requirement\u003c\/h3\u003e\n\u003cp\u003eAlways use the correct\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003ethermocouple extension wire\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003ethat matches the thermocouple type.\u003c\/p\u003e\n\u003cp\u003eExamples:\u003c\/p\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003eType K → Type K extension wire\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eType J → Type J extension wire\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eUsing standard copper wire will introduce:\u003c\/p\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003eJunction voltage errors\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eTemperature measurement drift\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eCalibration inaccuracy\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eThis is one of the most common field installation mistakes.\u003c\/p\u003e\n\u003chr\u003e\n\u003ch3\u003eGrounding Practice\u003c\/h3\u003e\n\u003cp\u003eRecommended grounding method:\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eGround the thermocouple shield at the monitor rack only\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eAvoid grounding at multiple points.\u003c\/p\u003e\n\u003cp\u003eImproper grounding can cause:\u003c\/p\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003eGround loops\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eSignal noise\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eUnstable temperature readings\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eSpecial attention is required when using:\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eGrounded-tip thermocouples\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThese sensors are more sensitive to grounding configuration.\u003c\/p\u003e\n\u003chr\u003e\n\u003ch3\u003eCold Junction Environment Control\u003c\/h3\u003e\n\u003cp\u003eDo not install the monitor rack in locations with:\u003c\/p\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003eRapid temperature changes\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eStrong airflow across terminal blocks\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eHigh thermal gradients\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eThese conditions can affect the accuracy of the internal cold junction compensation.\u003c\/p\u003e\n\u003cp\u003eTypical problematic locations:\u003c\/p\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003eNear ventilation ducts\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eClose to turbine exhaust paths\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eOutdoor panels without thermal shielding\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Bently Nevada","offers":[{"title":"Default Title","offer_id":52666850935147,"sku":"3300\/30","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/3227\/0443\/files\/bently-nevada-3300-30-position-monitor-module-aahygilvquw_7ed0cd2c-10d0-4b8c-b33c-9c8d65d61045.jpg?v=1765449041","url":"https:\/\/www.plcprotech.com\/products\/bently-nevada-3300-30-six-channel-temperature-tc-input-monitor","provider":"PLC ProTech Ltd.","version":"1.0","type":"link"}