{"product_id":"bently-nevada-330101-00-13-10-12-cn-3300-xl-8-mm-proximity-probe","title":"Bently Nevada 330101-00-13-10-12-CN 3300 XL 8 mm Proximity Probe","description":"\u003ch3\u003eDescription\u003c\/h3\u003e\n\u003cp\u003eOption 00 (0.0 in unthreaded length) and Option 12 (coaxial ClickLoc connector with FluidLoc cable) specify this 3300 XL \u003cstrong\u003e8 mm proximity probe\u003c\/strong\u003e configuration — \u003cstrong\u003e330101-00-13-10-12-CN\u003c\/strong\u003e, which features a 1.3 in overall case length and is backed by regional China hazardous area approvals.\u003c\/p\u003e\n\u003cp\u003eThe \u003cstrong\u003e330101-00-13-10-12-CN\u003c\/strong\u003e probe operates on the eddy-current measurement principle for non-contact vibration and shaft position monitoring in 3300 XL monitoring systems. This configuration incorporates a FluidLoc cable, which provides an internal physical seal inside the triaxial core to block steam, oil, and process liquids from migrating through the cable assembly. It terminates in a miniature gold-plated coaxial ClickLoc connector which clicks when hand-tightened, ensuring a secure connection without tools. This probe is designated with the -CN suffix, indicating it includes a China hazardous area approval package certified by NEPSI and CCC, making it ideal for restricted hazardous environments in the region where standard global options are not compliant.\u003c\/p\u003e\n\n\u003ch3\u003eFeatures\u003c\/h3\u003e\n\u003cul\u003e\n  \u003cli\u003e3\/8-24 UNF threaded stainless steel case with 1.3 in overall case length and 0.0 in unthreaded length.\u003c\/li\u003e\n  \u003cli\u003eFluidLoc cable construction blocks oil and other industrial process fluids from migrating through the internal wire pathways.\u003c\/li\u003e\n  \u003cli\u003eGold-plated coaxial ClickLoc connector provides a secure connection that resists vibration and prevents loosening.\u003c\/li\u003e\n  \u003cli\u003ePolyphenylene sulfide (PPS) probe tip offers high electrical insulation and structural resistance in aggressive fluid environments.\u003c\/li\u003e\n  \u003cli\u003e1.0 m FEP-insulated triaxial cable delivers excellent thermal stability and chemical resistance.\u003c\/li\u003e\n  \u003cli\u003eSuffix -CN provides regional China certification markings, including NEPSI and CCC hazardous area compliance.\u003c\/li\u003e\n  \u003cli\u003eCompatible with 3300 XL 8 mm Proximitor sensors (330180 series) and standard FEP extension cables in machine protection systems.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eApplications\u003c\/h3\u003e\n\u003cul\u003e\n  \u003cli\u003eSteam and gas turbine shaft vibration and radial displacement monitoring.\u003c\/li\u003e\n  \u003cli\u003eAxial thrust position and shaft movement measurement on high-speed pumps and compressors.\u003c\/li\u003e\n  \u003cli\u003eRotor dynamic behavior assessment in heavy industrial rotating machinery.\u003c\/li\u003e\n  \u003cli\u003ePermanent installations in generator bearing housings where liquid migration and high oil pressure are present.\u003c\/li\u003e\n  \u003cli\u003eMachinery protection monitoring in hazardous industrial zones across China.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eOrdering Information\u003c\/h3\u003e\n\u003ctable\u003e\n  \u003cthead\u003e\n    \u003ctr\u003e\n      \u003cth\u003eOption Segment\u003c\/th\u003e\n      \u003cth\u003eCode on This SKU\u003c\/th\u003e\n      \u003cth\u003eDescription\u003c\/th\u003e\n    \u003c\/tr\u003e\n  \u003c\/thead\u003e\n  \u003ctbody\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eOrderable Part Number\u003c\/td\u003e\n      \u003ctd\u003e\u003cstrong\u003e330101-00-13-10-12-CN\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e3300 XL 8 mm proximity probe, 3\/8-24 UNF thread, without armor\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eA - Unthreaded Length\u003c\/td\u003e\n      \u003ctd\u003e00\u003c\/td\u003e\n      \u003ctd\u003e0.0 in (fully threaded probe body)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eB - Overall Case Length\u003c\/td\u003e\n      \u003ctd\u003e13\u003c\/td\u003e\n      \u003ctd\u003e1.3 in overall case length\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eC - Total Length\u003c\/td\u003e\n      \u003ctd\u003e10\u003c\/td\u003e\n      \u003ctd\u003e1.0 m (3.3 feet) total cable length\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eD - Connector and Cable Option\u003c\/td\u003e\n      \u003ctd\u003e12\u003c\/td\u003e\n      \u003ctd\u003eMiniature coaxial ClickLoc connector, FluidLoc cable (without connector protector)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eSuffix -CN\u003c\/td\u003e\n      \u003ctd\u003e-CN\u003c\/td\u003e\n      \u003ctd\u003eChina hazardous area approval package (NEPSI and CCC certifications)\u003c\/td\u003e\n    \u003c\/tr\u003e\n  \u003c\/tbody\u003e\n\u003c\/table\u003e\n\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003ctable\u003e\n  \u003ctbody\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eManufacturer\u003c\/td\u003e\n      \u003ctd\u003eBently Nevada\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003ePart Number\u003c\/td\u003e\n      \u003ctd\u003e330101-00-13-10-12-CN\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eProduct Family\u003c\/td\u003e\n      \u003ctd\u003e3300 XL 8 mm Proximity Transducer System\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eProbe Tip Diameter\u003c\/td\u003e\n      \u003ctd\u003e8 mm\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eThread Size\u003c\/td\u003e\n      \u003ctd\u003e3\/8-24 UNF-2A\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eUnthreaded Case Length\u003c\/td\u003e\n      \u003ctd\u003e0.0 in (0 mm)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eOverall Case Length\u003c\/td\u003e\n      \u003ctd\u003e1.3 in (33 mm)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eTotal Cable Length\u003c\/td\u003e\n      \u003ctd\u003e1.0 m (3.3 ft)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eCable Construction\u003c\/td\u003e\n      \u003ctd\u003eFluidLoc triaxial FEP-insulated coaxial cable\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eConnector Style\u003c\/td\u003e\n      \u003ctd\u003eMiniature gold-plated coaxial ClickLoc connector (without protector)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eOperating Principle\u003c\/td\u003e\n      \u003ctd\u003eEddy current (non-contact proximity measurement)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eTarget Material\u003c\/td\u003e\n      \u003ctd\u003eAISI 4140 steel (standard calibration target)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eLinear Range\u003c\/td\u003e\n      \u003ctd\u003e2.0 mm (80 mils) from approximately 0.25 mm (10 mils) to 2.25 mm (90 mils)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eNominal Scale Factor\u003c\/td\u003e\n      \u003ctd\u003e7.87 V\/mm (200 mV\/mil)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eNominal Probe DC Resistance\u003c\/td\u003e\n      \u003ctd\u003e7.59 ohms +\/- 0.50 ohms (center conductor to outer conductor)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eStandard Operating Temperature\u003c\/td\u003e\n      \u003ctd\u003e-52 degC to +177 degC (-62 degF to +350 degF) for probe tip and cable\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003ePressure Seal Rating\u003c\/td\u003e\n      \u003ctd\u003eDesigned to seal differential pressure; exposing probe to temperatures below -34 degC (-30 degF) may cause seal degradation\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eProbe Case Torque\u003c\/td\u003e\n      \u003ctd\u003eRecommended: 11.2 N-m (100 in-lb); Maximum Rated: 33.9 N-m (300 in-lb)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eMaximum Connector Torque\u003c\/td\u003e\n      \u003ctd\u003e0.565 N-m (5 in-lb)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eMinimum Cable Bend Radius\u003c\/td\u003e\n      \u003ctd\u003e25.4 mm (1.0 in)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eTensile Strength\u003c\/td\u003e\n      \u003ctd\u003e330 N (75 lbf) probe case to probe lead; 270 N (60 lbf) lead to extension cable\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eMaterial (Probe Tip)\u003c\/td\u003e\n      \u003ctd\u003ePolyphenylene sulfide (PPS)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eMaterial (Probe Case)\u003c\/td\u003e\n      \u003ctd\u003eAISI 303 or 304 stainless steel (SST)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eMaterial (Connector)\u003c\/td\u003e\n      \u003ctd\u003eGold-plated brass or gold-plated beryllium copper\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eDimensions\u003c\/td\u003e\n      \u003ctd\u003e45 mm x 95 mm x 95 mm (H x W x D)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eWeight\u003c\/td\u003e\n      \u003ctd\u003e0.14 kg\u003c\/td\u003e\n    \u003c\/tr\u003e\n  \u003c\/tbody\u003e\n\u003c\/table\u003e\n\n\u003ch3\u003eInstallation Guidelines\u003c\/h3\u003e\n\u003cul\u003e\n  \u003cli\u003eMount the probe with the appropriate gap voltage (typically -10 Vdc to -11 Vdc, representing a gap of approximately 1.27 mm or 50 mils) against the target shaft.\u003c\/li\u003e\n  \u003cli\u003eEnsure thread engagement in the bearing casing does not exceed 14.3 mm (0.563 in) to avoid binding or damage to the 3\/8-24 threads.\u003c\/li\u003e\n  \u003cli\u003eMaintain the minimum permissible bend radius of 25.4 mm (1.0 in) during cable routing to prevent attenuation or physical failure of the triaxial core.\u003c\/li\u003e\n  \u003cli\u003eRoute the FEP-insulated cable with proper shielding and grounding techniques to preserve low-noise signal integrity inside the turbine or machine housing.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eCompliance and Certifications\u003c\/h3\u003e\n\u003cul\u003e\n  \u003cli\u003eNEPSI (National Supervision and Inspection Centre for Explosion Protection and Safety of Instrumentation, China)\u003c\/li\u003e\n  \u003cli\u003eCCC (China Compulsory Certification for Explosion Safety)\u003c\/li\u003e\n  \u003cli\u003eCE Compliant\u003c\/li\u003e\n  \u003cli\u003eRoHS Compliant\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Bently Nevada","offers":[{"title":"Default Title","offer_id":52666612318571,"sku":"330101-00-13-10-12-CN","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/3227\/0443\/files\/bently-nevada-330101-00-13-10-12-cn-3300-xl-8-mm-proximity-probes-o4scvxux5j2_0d716cfb-b7f3-413d-b696-455de69e058d.jpg?v=1765444157","url":"https:\/\/www.plcprotech.com\/products\/bently-nevada-330101-00-13-10-12-cn-3300-xl-8-mm-proximity-probe","provider":"PLC ProTech Ltd.","version":"1.0","type":"link"}