{"product_id":"bently-nevada-330103-00-11-50-02-05-3300-xl-8-mm-proximity-probe","title":"Bently Nevada 330103-00-11-50-02-05 3300 XL 8 mm Proximity Probe","description":"\u003ch3\u003eDescription\u003c\/h3\u003e\n\u003cp\u003eOption 00 (0 mm unthreaded length) and Option 11 (110 mm case length) specify this metric, unarmored 3300 XL 8 mm proximity probe configuration — \u003cstrong\u003e330103-00-11-50-02-05\u003c\/strong\u003e. This configuration incorporates a 5.0-meter total cable length (Option 50) and a miniature ClickLoc coaxial connector (Option 02), paired with CSA, ATEX, and IECEx hazardous area approvals (Option 05). Designed without mechanical armor, this model utilizes an M10 x 1 metric thread for direct installation into tapped machine housings where external protection is provided by conduit or the machine casing itself.\u003c\/p\u003e\n\u003cp\u003eThis configuration differs from imperial alternatives like the 330101 series by using metric threads and dimensions. Unlike armored variants such as the 330104 series, this unarmored probe uses standard coaxial cable, which provides superior routing flexibility in tight spaces. The 5.0-meter total length means the probe connects directly to a 5-meter Proximitor sensor without requiring an intermediate extension cable, reducing potential signal losses and connector failure points in the measurement chain.\u003c\/p\u003e\n\n\u003ch3\u003eFeatures\u003c\/h3\u003e\n\u003cul\u003e\n  \u003cli\u003eMetric M10 x 1 thread pattern specifically engineered for metric-standard machine casings.\u003c\/li\u003e\n  \u003cli\u003eOption 00 fully threaded probe body with 0 mm unthreaded length for solid mounting stability.\u003c\/li\u003e\n  \u003cli\u003eOption 11 overall case length of 110 mm to reach deep within standard machine housings.\u003c\/li\u003e\n  \u003cli\u003eOption 50 total cable length of 5.0 meters, allowing direct Proximitor sensor connection.\u003c\/li\u003e\n  \u003cli\u003eOption 02 ClickLoc miniature coaxial connector provides positive connection locking without special tools.\u003c\/li\u003e\n  \u003cli\u003eOption 05 agency approvals allow safe installation in CSA, ATEX, and IECEx certified hazardous environments.\u003c\/li\u003e\n  \u003cli\u003ePPS plastic probe tip material resists mechanical impacts and aggressive chemical environments.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eApplications\u003c\/h3\u003e\n\u003cp\u003eThis proximity probe is used in critical rotating machinery protection systems for measuring parameters such as:\u003c\/p\u003e\n\u003cul\u003e\n  \u003cli\u003eRadial shaft vibration\u003c\/li\u003e\n  \u003cli\u003eAxial shaft position \/ thrust position\u003c\/li\u003e\n  \u003cli\u003eEccentricity measurements\u003c\/li\u003e\n  \u003cli\u003ePhase reference (Keyphasor) sensing\u003c\/li\u003e\n  \u003cli\u003eCasing expansion and differential expansion\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eOrdering Information\u003c\/h3\u003e\n\u003ctable\u003e\n  \u003cthead\u003e\n    \u003ctr\u003e\n      \u003cth\u003eOption Segment\u003c\/th\u003e\n      \u003cth\u003eCode Value\u003c\/th\u003e\n      \u003cth\u003eMeaning\u003c\/th\u003e\n    \u003c\/tr\u003e\n  \u003c\/thead\u003e\n  \u003ctbody\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eBase Model \/ Ordering Code\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e\u003cstrong\u003e330103-00-11-50-02-05\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e3300 XL 8 mm Proximity Probe, M10 x 1 metric thread, without armor\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eA - Unthreaded Length\u003c\/td\u003e\n      \u003ctd\u003e00\u003c\/td\u003e\n      \u003ctd\u003e0 mm (fully threaded probe case)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eB - Overall Case Length\u003c\/td\u003e\n      \u003ctd\u003e11\u003c\/td\u003e\n      \u003ctd\u003e110 mm case length\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eC - Total Length\u003c\/td\u003e\n      \u003ctd\u003e50\u003c\/td\u003e\n      \u003ctd\u003e5.0 meters (16.4 feet) total system length\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eD - Connector and Cable-Type\u003c\/td\u003e\n      \u003ctd\u003e02\u003c\/td\u003e\n      \u003ctd\u003eMiniature coaxial ClickLoc connector, standard cable\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eE - Agency Approval\u003c\/td\u003e\n      \u003ctd\u003e05\u003c\/td\u003e\n      \u003ctd\u003eCSA, ATEX, and IECEx hazardous area approvals\u003c\/td\u003e\n    \u003c\/tr\u003e\n  \u003c\/tbody\u003e\n\u003c\/table\u003e\n\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003ctable\u003e\n  \u003cthead\u003e\n    \u003ctr\u003e\n      \u003cth\u003eParameter\u003c\/th\u003e\n      \u003cth\u003eSpecification\u003c\/th\u003e\n    \u003c\/tr\u003e\n  \u003c\/thead\u003e\n  \u003ctbody\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eManufacturer\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003eBently Nevada (Baker Hughes)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003ePart Number\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e330103-00-11-50-02-05\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eProduct Series\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e3300 XL 8 mm Proximity Transducer System\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eThread Specification\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003eM10 x 1 metric thread\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eArmor Protection\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003eWithout armor (standard coaxial sheath)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eUnthreaded Length\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e0 mm\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eCase Length\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e110 mm\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eTotal System Length\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e5.0 meters (16.4 feet)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eCable Outside Diameter\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e3.68 mm\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eConnector Type\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003eMiniature gold ClickLoc coaxial male connector\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eNominal DC Resistance\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e8.73 ohms +\/- 0.50 ohms (center to outer conductor)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eOperating Temperature\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e-52 degC to +177 degC (-62 degF to +350 degF)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eTarget Material Calibration\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003eAISI 4140 steel\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eProbe Tip Material\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003ePolyphenylene Sulfide (PPS) plastic\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eProbe Case Material\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e303 stainless steel\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eRelative Humidity Limit\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003eLess than 3% change in Average Scale Factor in 93% humidity\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eWeight\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e0.22 kg\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eDimensions (coiled)\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e150 mm x 150 mm x 40 mm (H x W x D)\u003c\/td\u003e\n    \u003c\/tr\u003e\n  \u003c\/tbody\u003e\n\u003c\/table\u003e\n\n\u003ch3\u003eConnections and Interfaces\u003c\/h3\u003e\n\u003cp\u003eThe probe utilizes a standard miniature ClickLoc coaxial connector interface to connect to the Proximitor sensor:\u003c\/p\u003e\n\u003ctable\u003e\n  \u003cthead\u003e\n    \u003ctr\u003e\n      \u003cth\u003eConnector Component\u003c\/th\u003e\n      \u003cth\u003eFunction\u003c\/th\u003e\n    \u003c\/tr\u003e\n  \u003c\/thead\u003e\n  \u003ctbody\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eCenter Conductor\u003c\/td\u003e\n      \u003ctd\u003eRF Signal (high frequency excitation)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eOuter Shield\u003c\/td\u003e\n      \u003ctd\u003eSignal Return \/ Common Ground\u003c\/td\u003e\n    \u003c\/tr\u003e\n  \u003c\/tbody\u003e\n\u003c\/table\u003e\n\n\u003ch3\u003eInstallation Guidelines\u003c\/h3\u003e\n\u003cul\u003e\n  \u003cli\u003e\n\u003cstrong\u003eProbe Gap:\u003c\/strong\u003e Gap the probe to 1.27 mm (50 mils) to achieve the nominal center of the 2.0 mm (80 mils) linear range.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eThread Engagement:\u003c\/strong\u003e Ensure thread engagement does not exceed 15 mm for the M10 x 1 case thread to avoid binding or damage.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eCable Routing:\u003c\/strong\u003e Route the standard coaxial cable inside protective conduit or structural channels to shield it from mechanical damage and abrasive contact.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eConnector Tightening:\u003c\/strong\u003e Tighten gold ClickLoc connectors finger-tight. Avoid using pliers as it can damage the miniature coaxial connection.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eEnvironmental Protection:\u003c\/strong\u003e Ensure the cable-to-extension connector interface is insulated or protected from moisture and turbine oil contamination.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eCompliance and Certifications\u003c\/h3\u003e\n\u003cul\u003e\n  \u003cli\u003e\n\u003cstrong\u003eCSA:\u003c\/strong\u003e Approved for Class I, Division 1 and 2, Groups A, B, C, and D hazardous locations when installed with appropriate barriers.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eATEX:\u003c\/strong\u003e II 1 G Ex ia IIC T1...T5 Ga\/Gb\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eIECEx:\u003c\/strong\u003e Ex ia IIC T1...T5 Ga\/Gb\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Bently Nevada","offers":[{"title":"Default Title","offer_id":52666734641515,"sku":"330103-00-11-50-02-05","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/3227\/0443\/files\/bently-nevada-330103-00-11-50-02-05-3300-xl-8-mm-probe-i5zp2vrsdya_b1139ced-65a1-4e16-89eb-b30200f84420.jpg?v=1765446753","url":"https:\/\/www.plcprotech.com\/products\/bently-nevada-330103-00-11-50-02-05-3300-xl-8-mm-proximity-probe","provider":"PLC ProTech Ltd.","version":"1.0","type":"link"}