{"product_id":"bently-nevada-330103-02-06-10-02-cn-3300-xl-8-mm-proximity-probe","title":"Bently Nevada 330103-02-06-10-02-CN 3300 XL 8 mm Proximity Probe","description":"\u003ch3\u003eProduct Overview\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003e330103-02-06-10-02-CN\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eis a Bently Nevada 3300 XL 8 mm proximity probe designed for continuous shaft vibration and position monitoring in rotating machinery. This probe belongs to the 3300 XL proximity transducer family and supports high-reliability vibration protection systems used in gas turbines, steam turbines, compressors, pumps, and critical process equipment. The probe uses a 3\/8-24 UNF threaded stainless steel housing with a standard cable and miniature ClickLoc connector for secure installation in confined industrial environments.\u003c\/p\u003e\n\u003cp\u003eThe probe operates in refinery units, petrochemical plants, offshore platforms, mining systems, and power generation facilities where accurate shaft displacement monitoring directly reduces unplanned shutdown risk. The CN approval suffix indicates Chinese hazardous area certification support, including NEPSI-related explosion protection compliance for explosive gas environments. Its stable output characteristics and low supply sensitivity improve signal integrity during long-term operation under vibration and temperature fluctuation conditions.\u003c\/p\u003e\n\u003ch3\u003eSuffix Breakdown\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e330103 = 3300 XL 8 mm Probe, 3\/8-24 UNF thread, without armor\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e02 = 20 mm unthreaded length\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e06 = 60 mm overall case length\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e10 = 1.0 metre total cable length\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e02 = Miniature coaxial ClickLoc connector with standard cable\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eCN = Chinese hazardous area approvals including NEPSI certification support\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003ctable class=\"w-fit min-w-(--thread-content-width)\"\u003e\n\u003cthead\u003e\n\u003ctr class=\"firstRow\"\u003e\n\u003cth class=\"\"\u003eParameter\u003c\/th\u003e\n\u003cth class=\"\"\u003eDetails\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003e330103-02-06-10-02-CN\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eBently Nevada\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduct Type\u003c\/td\u003e\n\u003ctd\u003e3300 XL 8 mm Proximity Probe\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOrigin\u003c\/td\u003e\n\u003ctd\u003eMade in U.S.A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProbe Thread\u003c\/td\u003e\n\u003ctd\u003e3\/8-24 UNF\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eUnthreaded Length\u003c\/td\u003e\n\u003ctd\u003e20 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOverall Case Length\u003c\/td\u003e\n\u003ctd\u003e60 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTotal Length\u003c\/td\u003e\n\u003ctd\u003e1.0 metre\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eConnector Type\u003c\/td\u003e\n\u003ctd\u003eMiniature coaxial ClickLoc connector\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCable Type\u003c\/td\u003e\n\u003ctd\u003eStandard cable\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAgency Approval\u003c\/td\u003e\n\u003ctd\u003eCN hazardous area approval\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOutput Resistance\u003c\/td\u003e\n\u003ctd\u003e50 Ohm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSupply Sensitivity\u003c\/td\u003e\n\u003ctd\u003eLess than 2 mV\/V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProbe Case Material\u003c\/td\u003e\n\u003ctd\u003eStainless steel\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temperature\u003c\/td\u003e\n\u003ctd\u003e-51 to +177 deg C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e1.3 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eShipping Weight\u003c\/td\u003e\n\u003ctd\u003e3.0 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Consumption\u003c\/td\u003e\n\u003ctd\u003ePassive sensor, external proximitor required\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eTechnical FAQs\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eCan this probe operate with standard 3300 XL proximitor sensors?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eYes. The probe supports standard Bently Nevada 3300 XL 8 mm proximitor sensor systems when the total system length matches calibration requirements.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eWhat does the CN suffix represent?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThe CN suffix represents Chinese country-specific hazardous area approvals. It typically includes NEPSI-related explosion protection certification for explosive gas environments.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eCan this probe replace older 3300 series probes?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eIn many retrofit projects, the 3300 XL series replaces older 3300 probes. Engineers must verify system length, mounting dimensions, and proximitor compatibility before replacement.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eWhat causes unstable shaft vibration readings?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eImproper gap voltage adjustment, damaged shielding, excessive cable bending, or incorrect grounding often cause unstable readings in proximity systems.\u003c\/p\u003e\n\u003chr\u003e\n\u003ch3\u003eEngineering \u0026amp; Installation Guide\u003c\/h3\u003e\n\u003cp\u003eInstall the probe with proper target material clearance and verify gap voltage during commissioning. Incorrect gap settings reduce linear measurement accuracy.\u003c\/p\u003e\n\u003cp\u003eRoute the extension cable separately from high-voltage motor cables and VFD wiring. This practice minimizes electromagnetic interference and prevents signal distortion.\u003c\/p\u003e\n\u003cp\u003eAvoid excessive cable tension near the ClickLoc connector. Repeated mechanical stress can damage internal conductor shielding and reduce long-term reliability.\u003c\/p\u003e\n\u003cp\u003eFor hazardous area installations, confirm that the complete transducer system maintains matching certification requirements, including barriers and associated apparatus.\u003c\/p\u003e","brand":"Bently Nevada","offers":[{"title":"Default Title","offer_id":52668322054507,"sku":"330103-02-06-10-02-CN","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/3227\/0443\/files\/330103-02-06-10-02-cn-ybmvd4mwdde_72ef972c-bd6a-4753-a468-519eb996b72c.jpg?v=1765521183","url":"https:\/\/www.plcprotech.com\/products\/bently-nevada-330103-02-06-10-02-cn-3300-xl-8-mm-proximity-probe","provider":"PLC ProTech Ltd.","version":"1.0","type":"link"}