{"product_id":"bently-nevada-330105-02-12-05-02-05-3300-xl-8-mm-reverse-mount-probe","title":"Bently Nevada 330105-02-12-05-02-05 3300 XL 8 mm Reverse Mount Probe","description":"\u003ch3\u003eDescription\u003c\/h3\u003e\n\u003cp\u003eThe \u003cstrong\u003e330105-02-12-05-02-05\u003c\/strong\u003e is a \u003cstrong\u003e3300 XL 8 mm reverse mount proximity probe\u003c\/strong\u003e designed for critical machinery vibration and axial position monitoring. This configuration features a 3\/8-24 UNF thread, a 1.2 inch case length, and a 0.5 meter total length with a standard miniature ClickLoc connector. Certified with Option 05 (CSA, ATEX, IECEx), this probe is suitable for hazardous area installations where reliable non-contact displacement measurement is required for sleeve-bearing or fluid-film bearing machinery.\u003c\/p\u003e\n\n\u003cp\u003eReverse mount probes like the 330105 are specifically engineered for applications where the probe must be installed through the machine case or housing, requiring the cable to exit through the rear of the probe body. The 3300 XL system, comprising this probe, a 330180 Proximitor sensor, and a 330130 extension cable, provides high-accuracy, linear output for monitoring shaft vibration and position in industrial rotating equipment such as steam turbines, gas compressors, and large centrifugal pumps.\u003c\/p\u003e\n\n\u003ch3\u003eFeatures\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eReverse mount configuration for through-case installation\u003c\/li\u003e\n\u003cli\u003e3\/8-24 UNF-2A thread for standardized machine mounting\u003c\/li\u003e\n\u003cli\u003eOption 05: CSA, ATEX, IECEx hazardous area approvals\u003c\/li\u003e\n\u003cli\u003eOption 02 (Connector): Miniature ClickLoc coaxial connector, standard cable\u003c\/li\u003e\n\u003cli\u003eDesigned for seamless integration with 3300 XL Proximitor sensors and extension cables\u003c\/li\u003e\n\u003cli\u003eHigh-accuracy eddy-current displacement measurement for fluid-film bearing monitoring\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eApplications\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eTurbine and compressor shaft vibration monitoring\u003c\/li\u003e\n\u003cli\u003eAxial position (thrust) measurement\u003c\/li\u003e\n\u003cli\u003eBearing wear and clearance monitoring\u003c\/li\u003e\n\u003cli\u003eCritical rotating machinery protection on 8 mm probe systems\u003c\/li\u003e\n\u003cli\u003eHazardous environment machinery control (oil and gas, petrochemical)\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eOrdering Information\u003c\/h3\u003e\n\u003ctable\u003e\n\u003ctr\u003e\n\u003cth\u003eOption\u003c\/th\u003e\n\u003cth\u003eCode\u003c\/th\u003e\n\u003cth\u003eDescription\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOrderable Part Number\u003c\/td\u003e\n\u003ctd\u003e330105-02-12-05-02-05\u003c\/td\u003e\n\u003ctd\u003e3300 XL 8 mm Reverse Mount Probe\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eA - Unthreaded Length\/Mounting\u003c\/td\u003e\n\u003ctd\u003e02\u003c\/td\u003e\n\u003ctd\u003eSpecific configuration for 330105 Reverse Mount\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eB - Case Length\u003c\/td\u003e\n\u003ctd\u003e12\u003c\/td\u003e\n\u003ctd\u003e1.2 inch case length\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eC - Total Length\u003c\/td\u003e\n\u003ctd\u003e05\u003c\/td\u003e\n\u003ctd\u003e0.5 meter (1.6 feet)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eD - Connector\/Cable\u003c\/td\u003e\n\u003ctd\u003e02\u003c\/td\u003e\n\u003ctd\u003eMiniature ClickLoc connector, standard cable\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eE - Agency Approval\u003c\/td\u003e\n\u003ctd\u003e05\u003c\/td\u003e\n\u003ctd\u003eCSA, ATEX, IECEx Approvals\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\n\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003ctable\u003e\n\u003ctr\u003e\n\u003ctd\u003eManufacturer\u003c\/td\u003e\n\u003ctd\u003eBently Nevada (Baker Hughes)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003e330105\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProbe Diameter\u003c\/td\u003e\n\u003ctd\u003e8 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMounting Type\u003c\/td\u003e\n\u003ctd\u003eReverse Mount\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eThread\u003c\/td\u003e\n\u003ctd\u003e3\/8-24 UNF-2A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTotal Length\u003c\/td\u003e\n\u003ctd\u003e0.5 m\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eConnector\u003c\/td\u003e\n\u003ctd\u003eMiniature ClickLoc\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCable Type\u003c\/td\u003e\n\u003ctd\u003eStandard (Non-FluidLoc)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAgency Approvals\u003c\/td\u003e\n\u003ctd\u003eCSA, ATEX, IECEx\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eLinear Range\u003c\/td\u003e\n\u003ctd\u003e2 mm (80 mils)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTemperature Range\u003c\/td\u003e\n\u003ctd\u003e-55 degC to +177 degC (probe tip)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\n\n\u003ch3\u003eInstallation Guidelines\u003c\/h3\u003e\n\u003cp\u003eEnsure the probe is installed in accordance with Bently Nevada installation drawings for the specific hazardous area classification (e.g., 141092 for ia). When mounting in hazardous locations, ensure the Proximitor sensor provides terminals with at least IP54 protection. Reverse mount probes should be tightened securely through the machine housing, ensuring that the unthreaded length and probe gap are correctly set to maintain linear measurement accuracy.\u003c\/p\u003e\n\n\u003ch3\u003eCompliance and Certifications\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eCSA, ATEX, IECEx approved for hazardous locations (Option 05)\u003c\/li\u003e\n\u003cli\u003eCE compliant\u003c\/li\u003e\n\u003cli\u003eRoHS compliant\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Bently Nevada","offers":[{"title":"Default Title","offer_id":52666862338411,"sku":"330105-02-12-05-02-05","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/3227\/0443\/files\/bently-nevada-330105-02-12-05-02-05-proximity-switch-y4faweyj4jn_33ccd408-bdbc-4aa6-b31a-78978a429c72.jpg?v=1765449339","url":"https:\/\/www.plcprotech.com\/products\/bently-nevada-330105-02-12-05-02-05-3300-xl-8-mm-reverse-mount-probe","provider":"PLC ProTech Ltd.","version":"1.0","type":"link"}