{"product_id":"bently-nevada-330105-02-12-90-02-05-3300-xl-8-mm-reverse-mount-probes","title":"Bently Nevada 330105-02-12-90-02-05 3300 XL 8 mm Reverse Mount Probes","description":"\u003ch3\u003eDescription\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003e330105-02-12-90-02-05\u003c\/strong\u003e is a 3300 XL 8 mm reverse mount proximity probe, featuring a 3\/8-24 UNF thread, 20 mm unthreaded length (Option 02), and 120 mm case length (Option 12). This \u003cstrong\u003e3300 XL 8 mm proximity probe\u003c\/strong\u003e is engineered for non-contact eddy-current displacement measurement, serving as a core component in vibration and position monitoring systems for critical rotating machinery. The system provides a precise voltage output proportional to the gap between the probe tip and the observed conductive surface, essential for monitoring shaft vibration, axial position, and rotor speed in turbines, compressors, and pumps.\u003c\/p\u003e\n\n\u003cp\u003eThis configuration includes a 9.0 meter total system length (Option 90) and uses a miniature coaxial ClickLoc connector with a standard cable (Option 02). It is rated for hazardous area environments with CSA, ATEX, and IECEx approvals (Option 05). The 3300 XL design ensures compatibility with 3300 XL Proximitor sensors and extension cables, maintaining the necessary electrical impedance match for reliable, long-term performance in industrial monitoring applications.\u003c\/p\u003e\n\n\u003ch3\u003eFeatures\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eReverse mount probe design with 3\/8-24 UNF thread for secure installation\u003c\/li\u003e\n\u003cli\u003eOption 02: 20 mm unthreaded probe length\u003c\/li\u003e\n\u003cli\u003eOption 12: 120 mm overall case length\u003c\/li\u003e\n\u003cli\u003eOption 90: 9.0 meter total length for integration into monitoring chains\u003c\/li\u003e\n\u003cli\u003eOption 02: Miniature ClickLoc coaxial connector with standard cable\u003c\/li\u003e\n\u003cli\u003eOption 05: Agency approvals including CSA, ATEX, and IECEx\u003c\/li\u003e\n\u003cli\u003eRugged design for continuous operation in demanding, high-vibration environments\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eApplications\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eTurbine and compressor shaft vibration monitoring\u003c\/li\u003e\n\u003cli\u003eRotor axial position and thrust measurement\u003c\/li\u003e\n\u003cli\u003eCritical rotating machinery protection\u003c\/li\u003e\n\u003cli\u003eFluid-film bearing performance monitoring\u003c\/li\u003e\n\u003cli\u003eHigh-speed industrial pump and motor shaft position\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eOrdering Information\u003c\/h3\u003e\n\u003ctable\u003e\n\u003ctr\u003e\n\u003cth\u003eOption\u003c\/th\u003e\n\u003cth\u003eCode on This SKU\u003c\/th\u003e\n\u003cth\u003eDescription\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOrderable Part Number\u003c\/td\u003e\n\u003ctd\u003e330105-02-12-90-02-05\u003c\/td\u003e\n\u003ctd\u003e3300 XL 8 mm Reverse Mount Probe\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eA - Unthreaded Length\u003c\/td\u003e\n\u003ctd\u003e02\u003c\/td\u003e\n\u003ctd\u003e20 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eB - Case Length\u003c\/td\u003e\n\u003ctd\u003e12\u003c\/td\u003e\n\u003ctd\u003e120 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eC - Total Length\u003c\/td\u003e\n\u003ctd\u003e90\u003c\/td\u003e\n\u003ctd\u003e9.0 meters (29.5 feet)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eD - Connector\/Cable\u003c\/td\u003e\n\u003ctd\u003e02\u003c\/td\u003e\n\u003ctd\u003eMiniature ClickLoc, standard cable\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eE - Agency Approval\u003c\/td\u003e\n\u003ctd\u003e05\u003c\/td\u003e\n\u003ctd\u003eCSA, ATEX, IECEx Approvals\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\n\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003ctable\u003e\n\u003ctr\u003e\n\u003ctd\u003eManufacturer\u003c\/td\u003e\n\u003ctd\u003eBently Nevada (Baker Hughes)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePart Number\u003c\/td\u003e\n\u003ctd\u003e330105-02-12-90-02-05\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduct Type\u003c\/td\u003e\n\u003ctd\u003e3300 XL 8 mm Reverse Mount Probe\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eThread Size\u003c\/td\u003e\n\u003ctd\u003e3\/8-24 UNF-2A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProbe Tip Diameter\u003c\/td\u003e\n\u003ctd\u003e8.0 mm (0.31 in)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTotal System Length\u003c\/td\u003e\n\u003ctd\u003e9.0 meters\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eConnector Type\u003c\/td\u003e\n\u003ctd\u003eMiniature ClickLoc coaxial\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCable Type\u003c\/td\u003e\n\u003ctd\u003eStandard coaxial cable\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAgency Approvals\u003c\/td\u003e\n\u003ctd\u003eCSA, ATEX, IECEx\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temperature\u003c\/td\u003e\n\u003ctd\u003e-55 degC to +177 degC (Probe tip dependent)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\n\n\u003ch3\u003eInstallation Guidelines\u003c\/h3\u003e\n\u003cp\u003eEnsure the probe is installed using the appropriate mounting hardware for 3\/8-24 UNF threads. Maintain proper gap settings as specified in the 3300 XL manual to ensure linear operation. The miniature ClickLoc connector must be clean and free of moisture during installation. When routing cables, avoid sharp bends and ensure the cable length and probe length match the system calibration (9.0 m total length in this configuration). In hazardous area installations, ensure compliance with the provided Bently Nevada drawing 141092 or 140979 as applicable.\u003c\/p\u003e\n\n\u003ch3\u003eCompliance and Certifications\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eCSA (Canadian Standards Association)\u003c\/li\u003e\n\u003cli\u003eATEX (Atmospheres Explosibles)\u003c\/li\u003e\n\u003cli\u003eIECEx (International Electrotechnical Commission Explosive)\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Bently Nevada","offers":[{"title":"Default Title","offer_id":52666531873131,"sku":"330105-02-12-90-02-05","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/3227\/0443\/files\/bently-nevada-330105-02-12-90-02-05-probe-34bs5qof1vq_3e3b743a-7fe7-41c9-b89e-42cc3f68bd89.jpg?v=1765440369","url":"https:\/\/www.plcprotech.com\/products\/bently-nevada-330105-02-12-90-02-05-3300-xl-8-mm-reverse-mount-probes","provider":"PLC ProTech Ltd.","version":"1.0","type":"link"}