{"product_id":"bently-nevada-330130-040-01-05-3300-xl-standard-extension-cable","title":"Bently Nevada 330130-040-01-05 3300 XL Standard Extension Cable","description":"\u003ch3\u003eDescription\u003c\/h3\u003e\n\u003cp\u003eThe \u003cstrong\u003e330130-040-01-05\u003c\/strong\u003e is a \u003cstrong\u003e3300 XL Standard Extension Cable\u003c\/strong\u003e configured for a 4.0 meter length, standard cable construction, and international agency approvals (CSA, ATEX, IECEx). This extension cable is a vital component of the 3300 XL 8 mm Proximity Transducer System, facilitating the connection between the proximity probe and the Proximitor sensor. It ensures signal integrity for non-contact eddy-current displacement measurement in critical machinery monitoring applications.\u003c\/p\u003e\n\n\u003cp\u003eThis specific configuration, identified by option code 01 (standard cable) and option code 05 (hazardous area approval), supports standard operating environments where environmental protection such as FluidLoc or armored shielding is not required, while maintaining full compliance for hazardous area installations. Proper selection of the extension cable length is required to ensure the total system length (probe plus extension cable) matches the calibrated 5-meter or 9-meter Proximitor sensor requirement.\u003c\/p\u003e\n\n\u003ch3\u003eFeatures\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e4.0 meter total cable length (Option 040)\u003c\/li\u003e\n\u003cli\u003eStandard cable construction (Option 01)\u003c\/li\u003e\n\u003cli\u003eCSA, ATEX, and IECEx hazardous area approvals (Option 05)\u003c\/li\u003e\n\u003cli\u003eCompatible with 3300 XL 8 mm probes and 3300 XL Proximitor sensors\u003c\/li\u003e\n\u003cli\u003eHigh-frequency signal transmission for vibration and position monitoring\u003c\/li\u003e\n\u003cli\u003eClickLoc connector design for secure, reliable attachment\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eApplications\u003c\/h3\u003e\n\u003cp\u003eThe 330130 extension cable is used in various industrial sectors, including power generation, oil and gas, petrochemical, and water treatment. Typical installations include:\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eTurbine and compressor shaft vibration monitoring\u003c\/li\u003e\n\u003cli\u003eRotor axial position measurement\u003c\/li\u003e\n\u003cli\u003eCritical rotating machinery protection on 3300 XL 8 mm probe systems\u003c\/li\u003e\n\u003cli\u003eHazardous area environments requiring CSA, ATEX, or IECEx certification\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eOrdering Information\u003c\/h3\u003e\n\u003ctable\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOption\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eCode on This SKU\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eDescription\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOrderable Part Number\u003c\/td\u003e\n\u003ctd\u003e330130-040-01-05\u003c\/td\u003e\n\u003ctd\u003e3300 XL Standard Extension Cable\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eA - Cable Length\u003c\/td\u003e\n\u003ctd\u003e040\u003c\/td\u003e\n\u003ctd\u003e4.0 meters (13.1 feet)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eB - Cable Option\u003c\/td\u003e\n\u003ctd\u003e01\u003c\/td\u003e\n\u003ctd\u003eStandard cable\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eC - Agency Approval\u003c\/td\u003e\n\u003ctd\u003e05\u003c\/td\u003e\n\u003ctd\u003eCSA, ATEX, IECEx Approvals\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\n\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003ctable\u003e\n\u003ctr\u003e\n\u003ctd\u003eManufacturer\u003c\/td\u003e\n\u003ctd\u003eBently Nevada (Baker Hughes)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePart Number\u003c\/td\u003e\n\u003ctd\u003e330130-040-01-05\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduct Type\u003c\/td\u003e\n\u003ctd\u003e3300 XL Standard Extension Cable\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCable Length\u003c\/td\u003e\n\u003ctd\u003e4.0 meters\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCable Type\u003c\/td\u003e\n\u003ctd\u003eStandard\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAgency Approvals\u003c\/td\u003e\n\u003ctd\u003eCSA, ATEX, IECEx\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSystem Compatibility\u003c\/td\u003e\n\u003ctd\u003e3300 XL 8 mm Proximity Transducer System\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\n\n\u003ch3\u003eInstallation Guidelines\u003c\/h3\u003e\n\u003cp\u003eEnsure that the total length of the extension cable and the probe equals the required length of the Proximitor sensor (e.g., 5 meters or 9 meters). When routing the cable, avoid sharp bends and maintain separation from high-voltage lines to prevent electromagnetic interference. Use the provided connector protectors if required by the installation environment. Grounding and shielding practices must adhere to the specific site requirements for hazardous area installations.\u003c\/p\u003e\n\n\u003ch3\u003eCompliance and Certifications\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eCSA (Canadian Standards Association)\u003c\/li\u003e\n\u003cli\u003eATEX (Atmospheres Explosibles)\u003c\/li\u003e\n\u003cli\u003eIECEx (International Electrotechnical Commission Explosive)\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Bently Nevada","offers":[{"title":"Default Title","offer_id":52666762658155,"sku":"330130-040-01-05","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/3227\/0443\/files\/bently-nevada-330130-040-01-05-3300-xl-standard-extension-cable-h2lvtzlkudp_4dfcec52-46a2-44d3-b7ed-3404b1951288.jpg?v=1765447155","url":"https:\/\/www.plcprotech.com\/products\/bently-nevada-330130-040-01-05-3300-xl-standard-extension-cable","provider":"PLC ProTech Ltd.","version":"1.0","type":"link"}