{"product_id":"bently-nevada-330130-070-00-cn-3300-xl-standard-extension-cable","title":"Bently Nevada 330130-070-00-CN 3300 XL Standard Extension Cable","description":"\u003ch3\u003eOperational Overview\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003e330130-070-00-CN\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eis a Bently Nevada 3300 XL extension cable used in vibration monitoring systems for turbines, compressors, generators, and other critical rotating equipment. It connects proximity probes to Proximitor modules and ensures stable signal transmission within the eddy-current measurement loop.\u003c\/p\u003e\n\u003cp\u003eThis 7.0 m cable supports medium-range installation layouts in industrial skids and turbine housings. It maintains impedance stability under vibration, thermal cycling, and electrical noise conditions. In condition monitoring systems, this cable plays a direct role in preserving signal accuracy and preventing false vibration alarms that can trigger unnecessary shutdowns.\u003c\/p\u003e\n\u003cp\u003eThe CN configuration provides region-specific compliance support while maintaining full compatibility with standard 3300 XL system architecture used globally in power generation and process industries.\u003c\/p\u003e\n\u003chr\u003e\n\u003ch3\u003eCable Structure Interpretation\u003c\/h3\u003e\n\u003ctable class=\"w-fit min-w-(--thread-content-width)\"\u003e\n\u003cthead\u003e\n\u003ctr class=\"firstRow\"\u003e\n\u003cth class=\"last:pe-10\"\u003eSegment\u003c\/th\u003e\n\u003cth class=\"last:pe-10\"\u003eMeaning\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e330130\u003c\/td\u003e\n\u003ctd\u003e3300 XL extension cable series\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e070\u003c\/td\u003e\n\u003ctd\u003e7.0 m cable length\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e00\u003c\/td\u003e\n\u003ctd\u003eStandard cable construction\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCN\u003c\/td\u003e\n\u003ctd\u003eRegional compliance approval option\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003eThe structure defines physical length, construction type, and regulatory classification within the Bently Nevada 3300 XL monitoring ecosystem.\u003c\/p\u003e\n\u003chr\u003e\n\u003ch3\u003eElectrical \u0026amp; Mechanical Specifications\u003c\/h3\u003e\n\u003ctable class=\"w-fit min-w-(--thread-content-width)\"\u003e\n\u003cthead\u003e\n\u003ctr class=\"firstRow\"\u003e\n\u003cth class=\"last:pe-10\"\u003eParameter\u003c\/th\u003e\n\u003cth class=\"last:pe-10\"\u003eSpecification\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003e330130-070-00-CN\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eBently Nevada\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOrigin\u003c\/td\u003e\n\u003ctd\u003eUnited States\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e1.5 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCable Length\u003c\/td\u003e\n\u003ctd\u003e7.0 m\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCable Type\u003c\/td\u003e\n\u003ctd\u003e3300 XL standard extension cable\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eElectrical Design\u003c\/td\u003e\n\u003ctd\u003e75 ohm triaxial compatible\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temperature\u003c\/td\u003e\n\u003ctd\u003e-51 to 177 deg C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Requirement\u003c\/td\u003e\n\u003ctd\u003ePassive component\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eApplication\u003c\/td\u003e\n\u003ctd\u003eProximity probe signal transmission\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSystem Compatibility\u003c\/td\u003e\n\u003ctd\u003eBently Nevada 3300 XL systems\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003chr\u003e\n\u003ch3\u003eProcurement Guide (Buying Strategy Notes)\u003c\/h3\u003e\n\u003cp\u003eExtension cables in Bently Nevada systems are not interchangeable without system consideration. Buyers must confirm three key parameters before purchase:\u003c\/p\u003e\n\u003cp\u003eFirst, verify total loop length including probe, extension cable, and Proximitor input requirements. Incorrect length selection affects gap voltage scaling and vibration accuracy.\u003c\/p\u003e\n\u003cp\u003eSecond, confirm connector type compatibility. 3300 XL systems require matched coaxial connector standards to ensure stable signal integrity under vibration conditions.\u003c\/p\u003e\n\u003cp\u003eThird, evaluate environmental exposure. In turbine and compressor installations, cable routing must account for heat, oil mist, and continuous vibration stress.\u003c\/p\u003e\n\u003cp\u003eFor long-term procurement planning, engineers typically standardize cable lengths across multiple machines to simplify spare parts inventory and reduce maintenance complexity.\u003c\/p\u003e\n\u003chr\u003e\n\u003ch3\u003ePurchase Notes (Compliance \u0026amp; Risk Control)\u003c\/h3\u003e\n\u003cp\u003eThis product is designed for industrial monitoring systems only and must be installed by qualified instrumentation personnel.\u003c\/p\u003e\n\u003cp\u003eIncorrect installation or mismatch with non-3300 XL components may result in signal distortion or monitoring failure.\u003c\/p\u003e\n\u003cp\u003eCN approval versions are intended for region-specific regulatory compliance. Buyers should confirm required certification scope before deployment in hazardous areas.\u003c\/p\u003e\n\u003cp\u003eAll cables should be stored in controlled environments before installation to avoid insulation aging or connector contamination.\u003c\/p\u003e\n\u003chr\u003e\n\u003ch3\u003eField Engineering Notes\u003c\/h3\u003e\n\u003cp\u003eMaintain physical separation between signal cables and high-voltage power lines to reduce electromagnetic interference in VFD-driven systems.\u003c\/p\u003e\n\u003cp\u003eAvoid sharp bends during installation. Excess mechanical stress may degrade shielding performance and long-term impedance stability.\u003c\/p\u003e\n\u003cp\u003eUse single-point grounding at the monitoring system level. Multiple grounding points can introduce loop current and measurement drift.\u003c\/p\u003e\n\u003chr\u003e\n\u003ch3\u003eField Troubleshooting Notes\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eWhat causes unstable vibration readings in extension cable systems?\u003c\/strong\u003e\u003cbr\u003eImproper routing, damaged shielding, or loose connector engagement are the most common causes.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eCan incorrect cable length affect system calibration?\u003c\/strong\u003e\u003cbr\u003eYes. Total loop length must match system design to ensure correct gap voltage output.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eIs CN version different in electrical performance?\u003c\/strong\u003e\u003cbr\u003eNo. CN only defines compliance approval, not electrical characteristics.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eWhat is the most common installation error?\u003c\/strong\u003e\u003cbr\u003eIncorrect cable routing near power conductors and improper connector locking.\u003c\/p\u003e\n\u003chr\u003e\n\u003ch3\u003eInstallation \u0026amp; Commissioning Notes\u003c\/h3\u003e\n\u003cp\u003eEnsure controlled routing from probe to Proximitor to avoid EMI coupling in turbine and compressor environments.\u003c\/p\u003e\n\u003cp\u003eVerify ClickLoc connector engagement during installation. Partial locking may cause intermittent signal loss under vibration.\u003c\/p\u003e\n\u003cp\u003eMaintain minimum bend radius throughout cable path to preserve shielding integrity and impedance stability.\u003c\/p\u003e","brand":"Bently Nevada","offers":[{"title":"Default Title","offer_id":52668321464683,"sku":"330130-070-00-CN","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/3227\/0443\/files\/bently-nevada-330130-070-00-cn-standard-extension-cable-on0jgnrrs1t_360967c8-6bde-432f-8b76-06a29971e9d1.jpg?v=1765448949","url":"https:\/\/www.plcprotech.com\/products\/bently-nevada-330130-070-00-cn-3300-xl-standard-extension-cable","provider":"PLC ProTech Ltd.","version":"1.0","type":"link"}