{"product_id":"bently-nevada-330130-085-01-cn-3300-xl-standard-extension-cable","title":"Bently Nevada 330130-085-01-CN 3300 XL Standard Extension Cable","description":"\u003ch3\u003eDescription\u003c\/h3\u003e\n\u003cp style=\"color: #2d3748; margin-bottom: 1rem;\"\u003eServing as a vital link in critical machinery protection architectures, the \u003cstrong\u003eBently Nevada 330130-085-01-CN\u003c\/strong\u003e provides high-fidelity signal transmission within the 3300 XL 8mm Proximity Transducer System. This specialized component bridges the connection between a 3300 XL proximity probe and a 3300 XL Proximitor Sensor, ensuring exact eddy current measurement propagation without signal degradation. Engineered for demanding industrial environments, it features robust \u003cstrong\u003earmored cable protection\u003c\/strong\u003e and meets regional certification compliance requirements, making it ideal for high-reliability vibration and shaft displacement monitoring applications.\u003c\/p\u003e\n\n\u003ch3\u003eFeatures\u003c\/h3\u003e\n\u003cul style=\"list-style-type: square; color: #2d3748; margin-bottom: 1.5rem; padding-left: 1.5rem;\"\u003e\n  \u003cli\u003e\n\u003cstrong\u003eFlexible Armor Layer:\u003c\/strong\u003e The integrated armor provides mechanical safeguarding against crushing, cutting, and environmental wear without compromising routing flexibility.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003ePrecise Electrical Matching:\u003c\/strong\u003e Calibrated to maintain strict capacitance and impedance standards, preserving measurement accuracy over long distances.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eGold-Plated Connectors:\u003c\/strong\u003e Corrosion-resistant coaxial interfaces ensure low contact resistance and long-term signal integrity.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eRobust Design:\u003c\/strong\u003e Optimized for operation in demanding industrial environments under high-temperature and fluid-exposure conditions.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eSystem Standardization:\u003c\/strong\u003e Fully compatible with standard Bently Nevada 3300 XL 8mm proximity sensor platforms.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eApplications\u003c\/h3\u003e\n\u003cul style=\"list-style-type: square; color: #2d3748; margin-bottom: 1.5rem; padding-left: 1.5rem;\"\u003e\n  \u003cli\u003eSteam and gas turbine shaft vibration and axial position monitoring.\u003c\/li\u003e\n  \u003cli\u003eBoiler feed pumps, heavy-duty compressors, and industrial blowers.\u003c\/li\u003e\n  \u003cli\u003eHydroelectric generator shaft vibration and radial displacement tracking.\u003c\/li\u003e\n  \u003cli\u003eGearbox input\/output shaft motion profiling in petrochemical applications.\u003c\/li\u003e\n  \u003cli\u003eAPI 670 machinery protection system deployments.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003cdiv style=\"overflow-x: auto; width: 100%; margin-bottom: 1.5rem;\"\u003e\n  \u003ctable style=\"border-collapse: collapse; width: 100%; color: #2d3748; border: 1px solid #e2e8f0;\"\u003e\n    \u003cthead\u003e\n      \u003ctr style=\"border-bottom: 2px solid #cbd5e0;\"\u003e\n        \u003cth style=\"padding: 0.75rem; text-align: left; font-weight: bold; border-right: 1px solid #e2e8f0;\"\u003eParameter\u003c\/th\u003e\n        \u003cth style=\"padding: 0.75rem; text-align: left; font-weight: bold;\"\u003eSpecification Value\u003c\/th\u003e\n      \u003c\/tr\u003e\n    \u003c\/thead\u003e\n    \u003ctbody\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 0.75rem; font-weight: bold; border-right: 1px solid #e2e8f0;\"\u003eManufacturer\u003c\/td\u003e\n        \u003ctd style=\"padding: 0.75rem;\"\u003eBently Nevada\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 0.75rem; font-weight: bold; border-right: 1px solid #e2e8f0;\"\u003eModel Number\u003c\/td\u003e\n        \u003ctd style=\"padding: 0.75rem;\"\u003e330130-085-01-CN\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 0.75rem; font-weight: bold; border-right: 1px solid #e2e8f0;\"\u003eProduct Series\u003c\/td\u003e\n        \u003ctd style=\"padding: 0.75rem;\"\u003e3300 XL 8mm Proximity Transducer System\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 0.75rem; font-weight: bold; border-right: 1px solid #e2e8f0;\"\u003eCable Length\u003c\/td\u003e\n        \u003ctd style=\"padding: 0.75rem;\"\u003e8.5 meters (27.9 feet)\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 0.75rem; font-weight: bold; border-right: 1px solid #e2e8f0;\"\u003eCable Protection Option\u003c\/td\u003e\n        \u003ctd style=\"padding: 0.75rem;\"\u003e01 (Armored Cable)\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 0.75rem; font-weight: bold; border-right: 1px solid #e2e8f0;\"\u003eAgency Approval Option\u003c\/td\u003e\n        \u003ctd style=\"padding: 0.75rem;\"\u003eCN (Country-Specific Approvals)\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 0.75rem; font-weight: bold; border-right: 1px solid #e2e8f0;\"\u003eConnector Plating\u003c\/td\u003e\n        \u003ctd style=\"padding: 0.75rem;\"\u003eGold-plated coaxial connectors\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 0.75rem; font-weight: bold; border-right: 1px solid #e2e8f0;\"\u003eNet Weight\u003c\/td\u003e\n        \u003ctd style=\"padding: 0.289 kg;\"\u003e0.289 kg\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 0.75rem; font-weight: bold; border-right: 1px solid #e2e8f0;\"\u003eShipping Weight (Calculated)\u003c\/td\u003e\n        \u003ctd style=\"padding: 0.75rem;\"\u003e1.500 kg\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 0.75rem; font-weight: bold; border-right: 1px solid #e2e8f0;\"\u003eCountry of Origin\u003c\/td\u003e\n        \u003ctd style=\"padding: 0.75rem;\"\u003eUnited States\u003c\/td\u003e\n      \u003c\/tr\u003e\n    \u003c\/tbody\u003e\n  \u003c\/table\u003e\n\u003c\/div\u003e\n\n\u003ch3\u003eConnections and Interfaces\u003c\/h3\u003e\n\u003cdiv style=\"overflow-x: auto; width: 100%; margin-bottom: 1.5rem;\"\u003e\n  \u003ctable style=\"border-collapse: collapse; width: 100%; color: #2d3748; border: 1px solid #e2e8f0;\"\u003e\n    \u003cthead\u003e\n      \u003ctr style=\"border-bottom: 2px solid #cbd5e0;\"\u003e\n        \u003cth style=\"padding: 0.75rem; text-align: left; font-weight: bold; border-right: 1px solid #e2e8f0;\"\u003eTerminal \/ Connection End\u003c\/th\u003e\n        \u003cth style=\"padding: 0.75rem; text-align: left; font-weight: bold;\"\u003eFunction and Installation Note\u003c\/th\u003e\n      \u003c\/tr\u003e\n    \u003c\/thead\u003e\n    \u003ctbody\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 0.75rem; font-weight: bold; border-right: 1px solid #e2e8f0;\"\u003eProbe End Connector\u003c\/td\u003e\n        \u003ctd style=\"padding: 0.75rem;\"\u003eConnects to the 3300 XL proximity probe lead. Connection must be tight and protected from fluid ingress using a connector protector.\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 0.75rem; font-weight: bold; border-right: 1px solid #e2e8f0;\"\u003eProximitor End Connector\u003c\/td\u003e\n        \u003ctd style=\"padding: 0.75rem;\"\u003eConnects directly to the terminal port on the 3300 XL Proximitor Sensor unit.\u003c\/td\u003e\n      \u003c\/tr\u003e\n    \u003c\/tbody\u003e\n  \u003c\/table\u003e\n\u003c\/div\u003e\n\n\u003ch3\u003eEmpirical Engineering Insights\u003c\/h3\u003e\n\u003ch4\u003eAlternative Models \u0026amp; Compatibility\u003c\/h4\u003e\n\u003cp style=\"color: #2d3748; margin-bottom: 1rem;\"\u003eThis 8.5-meter cable is specifically calibrated for use in 9.0-meter total system length configurations (when paired with a 0.5-meter probe). Do not mix this cable with 5.0-meter system components or non-XL proximity hardware, as this mismatch will cause significant calibration slope errors and incorrect voltage output signals from the Proximitor.\u003c\/p\u003e\n\n\u003ch4\u003eApplication Pitfalls \u0026amp; Engineering Notes\u003c\/h4\u003e\n\u003cp style=\"color: #2d3748; margin-bottom: 1rem;\"\u003eWhile the armored shielding (Option 01) protects the inner conductor from mechanical damage, installing engineers must still respect the minimum static bend radius of 25.4 mm (1.0 inch). Kinking or exceeding this bend radius will alter the coaxial geometry, resulting in calibration drift or high-frequency noise spikes in the vibration monitoring system.\u003c\/p\u003e\n\n\u003ch4\u003eCommissioning \u0026amp; Wiring Tips\u003c\/h4\u003e\n\u003cp style=\"color: #2d3748; margin-bottom: 1rem;\"\u003eWhen routing armored cables through conduit or cable trays, avoid laying them directly parallel to high-voltage AC motor power lines or variable frequency drive (VFD) cables. Ensure the cable armor does not come into electrical contact with structural steel at multiple points to avoid creating noise-inducing ground loops.\u003c\/p\u003e\n\n\u003ch3\u003eInstallation Guidelines\u003c\/h3\u003e\n\u003cdiv style=\"background-color: #fff5f5; border-left: 4px solid #c53030; padding: 1rem; margin-bottom: 1.5rem; color: #9b2c2c;\"\u003e\n  \u003cstrong\u003eCRITICAL WARNING:\u003c\/strong\u003e Prior to installation, ensure that the machinery protection system rack is placed in bypass and that all relevant machine interlocks\/trips are isolated. De-energize the Proximitor Sensor power source before connecting or disconnecting the transducer cables to prevent transient voltage-induced sensor damage.\n\u003c\/div\u003e\n\n\u003cdiv style=\"display: flex; flex-direction: column; gap: 1rem; margin-bottom: 1.5rem;\"\u003e\n  \u003cdiv style=\"display: flex; align-items: flex-start; gap: 1rem;\"\u003e\n    \u003cspan style=\"background-color: #2b6cb0; color: #ffffff; width: 2rem; height: 2rem; border-radius: 50%; display: flex; align-items: center; justify-content: center; font-weight: bold; flex-shrink: 0;\"\u003e1\u003c\/span\u003e\n    \u003cp style=\"color: #2d3748; margin: 0; padding-top: 0.25rem;\"\u003eVerify that the extension cable length (8.5m) and the probe length (0.5m) equal the total calibrated system length required by the Proximitor Sensor (9.0m system).\u003c\/p\u003e\n  \u003c\/div\u003e\n  \u003cdiv style=\"display: flex; align-items: flex-start; gap: 1rem;\"\u003e\n    \u003cspan style=\"background-color: #2b6cb0; color: #ffffff; width: 2rem; height: 2rem; border-radius: 50%; display: flex; align-items: center; justify-content: center; font-weight: bold; flex-shrink: 0;\"\u003e2\u003c\/span\u003e\n    \u003cp style=\"color: #2d3748; margin: 0; padding-top: 0.25rem;\"\u003eClean both the probe lead connector and the extension cable connector with an approved residue-free electronic contact cleaner before joining.\u003c\/p\u003e\n  \u003c\/div\u003e\n  \u003cdiv style=\"display: flex; align-items: flex-start; gap: 1rem;\"\u003e\n    \u003cspan style=\"background-color: #2b6cb0; color: #ffffff; width: 2rem; height: 2rem; border-radius: 50%; display: flex; align-items: center; justify-content: center; font-weight: bold; flex-shrink: 0;\"\u003e3\u003c\/span\u003e\n    \u003cp style=\"color: #2d3748; margin: 0; padding-top: 0.25rem;\"\u003eJoin the connectors hand-tight. Apply a connector protector sleeve over the junction to prevent moisture intrusion and provide structural support.\u003c\/p\u003e\n  \u003c\/div\u003e\n  \u003cdiv style=\"display: flex; align-items: flex-start; gap: 1rem;\"\u003e\n    \u003cspan style=\"background-color: #2b6cb0; color: #ffffff; width: 2rem; height: 2rem; border-radius: 50%; display: flex; align-items: center; justify-content: center; font-weight: bold; flex-shrink: 0;\"\u003e4\u003c\/span\u003e\n    \u003cp style=\"color: #2d3748; margin: 0; padding-top: 0.25rem;\"\u003eRoute the armored cable to the Proximitor housing. Secure with clamps at regular intervals to eliminate whipping or cable sway in high-vibration zones.\u003c\/p\u003e\n  \u003c\/div\u003e\n\u003c\/div\u003e","brand":"Bently Nevada","offers":[{"title":"Default Title","offer_id":52668306817387,"sku":"330130-085-01-CN","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/3227\/0443\/files\/330130-085-01-CN-3k31pp4psu0_8a9322c7-a331-4bd9-a10b-048f625923b3.jpg?v=1765520689","url":"https:\/\/www.plcprotech.com\/products\/bently-nevada-330130-085-01-cn-3300-xl-standard-extension-cable","provider":"PLC ProTech Ltd.","version":"1.0","type":"link"}