{"product_id":"bently-nevada-330180-x1-cn-mod-143416-34-3300-xl-proximitor-sensor","title":"Bently Nevada 330180-X1-CN MOD: 143416-34 3300 XL Proximitor Sensor","description":"\u003ch3\u003eProduct Overview\u003c\/h3\u003e\n\u003cp\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e330180-X1-CN (MOD: 143416-34)\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eis a high-performance signal conditioning unit and a core component of the Bently Nevada 3300 XL series. This\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e330180-X1-CN\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eProximitor Sensor provides specialized non-contacting measurements of shaft vibration, radial position, and axial displacement. Specifically modified under the\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e143416-34\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003edesignation for tailored industrial requirements, it is widely deployed in gas turbines, high-speed centrifugal compressors, and power generation units. In heavy industries like oil refining and mining, where machinery downtime can cost millions per hour, this sensor serves as a critical early-warning system. By converting eddy current probe signals into precise voltage outputs, it enables DCS and TSI systems to detect bearing wear and rotor instability before catastrophic failure occurs, ensuring maximum asset availability and personnel safety.\u003c\/p\u003e\n\u003ch3\u003eSuffix Breakdown\u003c\/h3\u003e\n\u003cp\u003eThe alphanumeric configuration of the\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e330180-X1-CN MOD: 143416-34\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eindicates the following technical specifications:\u003c\/p\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003e330180:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eBase model for the 3300 XL Proximitor Sensor series.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eX1 (Mounting\/Length):\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eStandardized DIN-rail mounting option for rapid and secure installation within industrial control cabinets.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eCN (Agency Approval):\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eTriple-certified for hazardous environments, carrying ATEX, IECEx, and the mandatory Chinese NEPSI markings, ensuring compliance for international and Mainland China projects.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eMOD: 143416-34:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eA specific factory modification. Modification 143416-34 typically refers to customized electrical scaling or specific housing adaptations required for unique machinery interfaces or legacy system compatibility.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr class=\"firstRow\"\u003e\n\u003ctd\u003e\u003cstrong\u003eAttribute\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eSpecification Details\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eModel\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e330180-X1-CN (MOD: 143416-34)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eBrand\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eBently Nevada (Baker Hughes)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eOrigin\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eU.S.A.\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eTransducer Type\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eEddy Current \/ Proximity\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eOutput Type\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eAnalog Voltage (proportional to gap)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eMounting\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e35 mm DIN-rail\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eOperating Temp\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e-51 to +100 deg C\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eHazardous Ratings\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eATEX, IECEx, NEPSI\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eInput Supply\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e-17.5 to -26 VDC\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eShipping Weight\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e2.0 kg\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eTechnical FAQs\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eWhat does the 143416-34 modification represent?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eFactory \"MOD\" codes like\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e143416-34\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eindicate that the internal circuitry or physical housing has been adjusted from the standard 330180 configuration. These modifications are usually requested for specific OEM turbine requirements or to match a non-standard probe impedance.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eIs the NEPSI marking mandatory for my installation?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eIf your project is located within the People's Republic of China and is situated in a hazardous area, the\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e-CN\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e(NEPSI) approval is a legal requirement for electrical safety and insurance compliance, alongside global ATEX\/IECEx standards.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eDoes this module include the proximity probe?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eNo. The\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e330180-X1-CN\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eis the signal conditioning Proximitor only. To form a complete measurement loop, you must also utilize a 3300 XL probe and an extension cable gapped and calibrated to the same system length.\u003c\/p\u003e\n\u003chr\u003e\n\u003ch3\u003eEngineering \u0026amp; Installation Guide\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eGap Voltage Calibration\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eDuring commissioning, the proximity probe must be gapped while the shaft is at rest. Connect a digital multimeter to the \"Prox\" and \"Com\" terminals on the\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e330180-X1-CN\u003c\/strong\u003e. For a standard 3300 XL 8 mm system, a typical gap voltage is -10.0 VDC. Adjust the probe distance until this voltage is achieved, placing the sensor in the center of its linear range for optimal vibration tracking.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eCabling and EMI Shielding\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eSince this unit is DIN-rail mounted (X1 option), ensure the rail itself is properly bonded to the instrument ground. Field cables from the probe must be shielded twisted-pair. The shield should be grounded only at the Proximitor end (or the monitor rack) to prevent ground loops. In high-vibration environments, use connector protectors on the coaxial junctions to prevent the cable from loosening over time.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eHazardous Area Integrity\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eBecause this unit carries\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e-CN\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e(NEPSI) and ATEX approvals, any installation in a Class 1 Division 1 or Zone 0\/1 area must utilize appropriate Zener barriers or galvanic isolators between the Proximitor and the monitoring system. Ensure all cable glands and seals meet the local explosion-proof requirements specified in the project’s safety certification.\u003c\/p\u003e","brand":"Bently Nevada","offers":[{"title":"Default Title","offer_id":52668317696363,"sku":"143416-22","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/3227\/0443\/files\/143416-22-330180-x1-cn-wuvha3hxydq_b8de4fea-1a9a-4a61-8bac-8e5309092dd8.jpg?v=1765521078","url":"https:\/\/www.plcprotech.com\/products\/bently-nevada-330180-x1-cn-mod-143416-34-3300-xl-proximitor-sensor","provider":"PLC ProTech Ltd.","version":"1.0","type":"link"}