{"product_id":"bently-nevada-330701-00-30-10-02-05-3300-xl-11-mm-proximity-probe","title":"Bently Nevada 330701-00-30-10-02-05 3300 XL 11 mm Proximity Probe","description":"\u003ch3\u003eDescription\u003c\/h3\u003e\n\u003cp\u003eFully threaded 1\/2-20 UNF steel probe body (Option 00 unthreaded) with a 3.0 in case (Option 30) and a 1.0 m lead (Option 10) specifies this \u003cstrong\u003e330701-00-30-10-02-05\u003c\/strong\u003e \u003cstrong\u003e3300 XL 11 mm proximity probe\u003c\/strong\u003e configuration.\u003c\/p\u003e\n\u003cp\u003eThis specific configuration includes a Miniature coaxial ClickLoc connector on a standard FEP-insulated coaxial cable (Option 02), supplied without a connector protector or protective armor. It is certified for hazardous areas under the Option 05 Multiple Approvals package, including ATEX, IECEx, and CSA standards for intrinsic safety and non-incendive installations. The 11 mm tip diameter provides an extended 4.0 mm linear range compared to standard 8 mm systems, rendering it suitable for larger-scale vibration and position measurements on rotating machinery.\u003c\/p\u003e\n\n\u003ch3\u003eFeatures\u003c\/h3\u003e\n\u003cul\u003e\n  \u003cli\u003eOption 00 specifies a 0.0 inch unthreaded length for maximum thread engagement in the mounting bracket or machine housing.\u003c\/li\u003e\n  \u003cli\u003eOption 30 provides a 3.0 inch overall case length, constructed from durable AISI 304 stainless steel.\u003c\/li\u003e\n  \u003cli\u003eOption 10 provides a 1.0 meter (3.3 feet) integrated FEP-insulated coaxial cable to connect directly with a 3300 XL 11 mm extension cable.\u003c\/li\u003e\n  \u003cli\u003eOption 02 defines a Miniature coaxial ClickLoc connector without a connector protector, using standard 75 ohm triaxial cable.\u003c\/li\u003e\n  \u003cli\u003eOption 05 provides Multiple Approvals, making this probe suitable for deployment in Class I Division 1, Zone 0, and Zone 2 hazardous areas.\u003c\/li\u003e\n  \u003cli\u003eExtended linear range of 4.0 mm (160 mils) accommodates larger axial movements and target gaps.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eApplications\u003c\/h3\u003e\n\u003cul\u003e\n  \u003cli\u003eShaft vibration monitoring on large steam turbines, gas turbines, and industrial compressors.\u003c\/li\u003e\n  \u003cli\u003eAxial thrust position measurement where larger target gaps require an extended linear range.\u003c\/li\u003e\n  \u003cli\u003eDifferential expansion monitoring on thermal rotating machinery.\u003c\/li\u003e\n  \u003cli\u003eRod drop and rod position measurements in reciprocating compressors.\u003c\/li\u003e\n  \u003cli\u003ePhase reference (Keyphasor) and speed monitoring.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eOrdering Information\u003c\/h3\u003e\n\u003ctable\u003e\n  \u003cthead\u003e\n    \u003ctr\u003e\n      \u003cth\u003eOption \/ Segment\u003c\/th\u003e\n      \u003cth\u003eCode on This SKU\u003c\/th\u003e\n      \u003cth\u003eDescription \/ Meaning\u003c\/th\u003e\n    \u003c\/tr\u003e\n  \u003c\/thead\u003e\n  \u003ctbody\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eOrderable Part Number\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e\u003cstrong\u003e330701-00-30-10-02-05\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e3300 XL 11 mm Probe, 1\/2-20 UNF thread, without armor\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eA - Unthreaded Length Option\u003c\/td\u003e\n      \u003ctd\u003e00\u003c\/td\u003e\n      \u003ctd\u003e0.0 in (0 mm) unthreaded length\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eB - Overall Case Length Option\u003c\/td\u003e\n      \u003ctd\u003e30\u003c\/td\u003e\n      \u003ctd\u003e3.0 in (76 mm) case length\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eC - Total Length Option\u003c\/td\u003e\n      \u003ctd\u003e10\u003c\/td\u003e\n      \u003ctd\u003e1.0 meter (3.3 feet) total probe length\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eD - Connector and Cable-Type Option\u003c\/td\u003e\n      \u003ctd\u003e02\u003c\/td\u003e\n      \u003ctd\u003eMiniature ClickLoc coaxial connector, standard cable (no protector)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eE - Agency Approval Option\u003c\/td\u003e\n      \u003ctd\u003e05\u003c\/td\u003e\n      \u003ctd\u003eMultiple Approvals (including CSA, ATEX, IECEx, and NEPSI)\u003c\/td\u003e\n    \u003c\/tr\u003e\n  \u003c\/tbody\u003e\n\u003c\/table\u003e\n\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003ctable\u003e\n  \u003cthead\u003e\n    \u003ctr\u003e\n      \u003cth\u003eParameter\u003c\/th\u003e\n      \u003cth\u003eSpecification Value\u003c\/th\u003e\n    \u003c\/tr\u003e\n  \u003c\/thead\u003e\n  \u003ctbody\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eManufacturer\u003c\/td\u003e\n      \u003ctd\u003eBently Nevada (Baker Hughes)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003ePart Number\u003c\/td\u003e\n      \u003ctd\u003e330701-00-30-10-02-05\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eProbe Tip Diameter\u003c\/td\u003e\n      \u003ctd\u003e11 mm\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eProbe Tip Material\u003c\/td\u003e\n      \u003ctd\u003ePolyphenylene sulfide (PPS)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eProbe Case Material\u003c\/td\u003e\n      \u003ctd\u003eAISI 304 stainless steel (SST)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eThread Size\u003c\/td\u003e\n      \u003ctd\u003e1\/2-20 UNF-2A\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eArmor Option\u003c\/td\u003e\n      \u003ctd\u003eWithout armor\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eCable Type\u003c\/td\u003e\n      \u003ctd\u003e75 ohm triaxial, FEP insulated\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eConnector Type\u003c\/td\u003e\n      \u003ctd\u003eMiniature male coaxial ClickLoc\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eConnector Material\u003c\/td\u003e\n      \u003ctd\u003eGold-plated brass\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eSystem Compatibility\u003c\/td\u003e\n      \u003ctd\u003e3300 XL 11 mm Transducer System (compatible with 330730 extension cable and 330780 Proximitor)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eLinear Measurement Range\u003c\/td\u003e\n      \u003ctd\u003e4.0 mm (160 mils) from approximately 0.5 mm to 4.5 mm (20 to 180 mils) target distance\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eOutput Signal Range\u003c\/td\u003e\n      \u003ctd\u003eApproximately -1 Vdc to -17 Vdc over linear range\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eIncremental Scale Factor (ISF)\u003c\/td\u003e\n      \u003ctd\u003e3.94 V\/mm (100 mV\/mil) plus or minus 10% under standard calibration\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eStandard Calibration Target\u003c\/td\u003e\n      \u003ctd\u003eAISI 4140 steel (minimum 31 mm \/ 1.2 in diameter flat target)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eRecommended Gap Setting\u003c\/td\u003e\n      \u003ctd\u003e2.5 mm (100 mils)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eDeviation from Straight Line (DSL)\u003c\/td\u003e\n      \u003ctd\u003eLess than plus or minus 0.10 mm (plus or minus 4 mils) at standard ambient conditions\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eTensile Strength (Maximum Rated)\u003c\/td\u003e\n      \u003ctd\u003e330 N (75 lb) probe case to probe lead; 270 N (60 lb) probe lead to extension cable connector\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eProbe Case Torque (Recommended)\u003c\/td\u003e\n      \u003ctd\u003e15.2 N-m (133 in-lb)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eProbe Case Torque (Maximum Rated)\u003c\/td\u003e\n      \u003ctd\u003e45.2 N-m (400 in-lb)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eMinimum Bend Radius\u003c\/td\u003e\n      \u003ctd\u003e25.4 mm (1.0 in)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eProbe Temperature Range (Operating)\u003c\/td\u003e\n      \u003ctd\u003e-51 degC to +177 degC (-60 degF to +351 degF)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003ePressure Sealing\u003c\/td\u003e\n      \u003ctd\u003eViton O-ring differential pressure seal between tip and case (not pressure tested)\u003c\/td\u003e\n    \u003c\/tr\u003e\n  \u003c\/tbody\u003e\n\u003c\/table\u003e\n\n\u003ch3\u003eInstallation Guidelines\u003c\/h3\u003e\n\u003cul\u003e\n  \u003cli\u003eMaintain a minimum probe target gap of 2.5 mm (100 mils) to position the system output near the center of the -9 Vdc linear range.\u003c\/li\u003e\n  \u003cli\u003eEnsure that probe casing thread engagement is secure. Torque standard 1\/2-20 UNF casings to the recommended 15.2 N-m (133 in-lb) value, taking care not to exceed 45.2 N-m (400 in-lb).\u003c\/li\u003e\n  \u003cli\u003eAvoid routing coaxial cables around sharp metal edges. Respect the minimum bend radius of 25.4 mm (1.0 in) to prevent internal conductor damage.\u003c\/li\u003e\n  \u003cli\u003eEnsure that connections between the probe lead and extension cable are finger-tight; do not use pliers to tighten ClickLoc connectors.\u003c\/li\u003e\n  \u003cli\u003eFor hazardous area applications, install the proximity system in accordance with Bently Nevada control drawings 141092 (for intrinsically safe installations) or 140979 (for non-incendive environments).\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eCompliance and Certifications\u003c\/h3\u003e\n\u003cul\u003e\n  \u003cli\u003eEMC: Standards EN 61000-6-2 (Industrial Immunity) and EN 61000-6-4 (Industrial Emissions) per European Community Directive 2014\/30\/EU.\u003c\/li\u003e\n  \u003cli\u003eRoHS: Compliant with European Directive 2011\/65\/EU and China RoHS regulations (SJ\/T 11364-2024 Environmentally Friendly Use Period of 15 years).\u003c\/li\u003e\n  \u003cli\u003eFunctional Safety: Certified for SIL 2 (HFT = 0) and SIL 3 (HFT = 1) applications under relevant safety-instrumented systems.\u003c\/li\u003e\n  \u003cli\u003eHazardous Area Approvals (Option 05): Certified by CSA (US and Canada), ATEX, and IECEx for intrinsic safety (Ex ia IIC T5...T1 Ga) and non-sparking\/non-incendive environments (Ex nA\/ec IIC T5...T1 Gc).\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Bently Nevada","offers":[{"title":"Default Title","offer_id":52666558546283,"sku":"330701-00-30-10-02-05","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/3227\/0443\/files\/bently-nevada-330701-00-30-10-02-05-3300-xl-11-mm-proximity-probes-1azl1vflzz1_8540c9a5-bf1d-4a6a-9ca9-04980f0854a8.jpg?v=1765440644","url":"https:\/\/www.plcprotech.com\/products\/bently-nevada-330701-00-30-10-02-05-3300-xl-11-mm-proximity-probe","provider":"PLC ProTech Ltd.","version":"1.0","type":"link"}