{"product_id":"bently-nevada-330703-000-040-10-02-00-3300-xl-11-mm-proximity-probe","title":"Bently Nevada 330703-000-040-10-02-00 3300 XL 11 mm Proximity Probe","description":"\u003ch3\u003eDescription\u003c\/h3\u003e\n\u003cp\u003eAn unarmored, metric thread M14 x 1.5 probe body with 0 mm unthreaded length (Option 000) and 40 mm overall case length (Option 040) specifies the configuration of the \u003cstrong\u003e330703-000-040-10-02-00\u003c\/strong\u003e \u003cstrong\u003e3300 XL 11 mm Proximity Probe\u003c\/strong\u003e.\u003c\/p\u003e\n\u003cp\u003eThis configuration incorporates a 1.0-meter total length standard triaxial cable (Option 10) terminated in a miniature coaxial ClickLoc connector without a connector protector (Option 02). Unlike armored options within the 3300 XL series, this unarmored variant is designed for installation environments where existing protective conduits or machine enclosures shield the cable from mechanical damage. The probe is supplied with no agency approvals required (Option 00), making it suitable for standard industrial, non-hazardous monitoring locations.\u003c\/p\u003e\n\n\u003ch3\u003eFeatures\u003c\/h3\u003e\n\u003cul\u003e\n  \u003cli\u003eM14 x 1.5 metric thread case (unarmored) constructed from AISI 304 stainless steel.\u003c\/li\u003e\n  \u003cli\u003ePolyphenylene sulfide (PPS) probe tip material for chemical and mechanical robustness.\u003c\/li\u003e\n  \u003cli\u003e0 mm unthreaded length (Option 000) paired with a 40 mm case length (Option 040).\u003c\/li\u003e\n  \u003cli\u003e1.0-meter (3.3 feet) standard triaxial cable insulated with fluoroethylene propylene (FEP).\u003c\/li\u003e\n  \u003cli\u003eGold-plated brass miniature coaxial ClickLoc connector (Option 02) without connector protector.\u003c\/li\u003e\n  \u003cli\u003eGeneral-purpose configuration (Option 00) with no agency approvals required.\u003c\/li\u003e\n  \u003cli\u003e75 Ohm triaxial probe cable matched to 3300 XL 11 mm Proximitor sensor impedance.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eApplications\u003c\/h3\u003e\n\u003cp\u003eThis proximity probe is used within a 3300 XL 11 mm monitoring chain for non-contacting displacement measurement. Typical target installations include:\u003c\/p\u003e\n\u003cul\u003e\n  \u003cli\u003eRadial vibration and position monitoring on utility turbines and compressor shafts.\u003c\/li\u003e\n  \u003cli\u003eAxial position and thrust measurement on critical rotating industrial machinery.\u003c\/li\u003e\n  \u003cli\u003eKeyphasor and speed measurement on high-speed industrial shafts.\u003c\/li\u003e\n  \u003cli\u003eGeneral machinery protection monitoring in non-hazardous industrial environments.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eOrdering Information\u003c\/h3\u003e\n\u003ctable\u003e\n  \u003cthead\u003e\n    \u003ctr\u003e\n      \u003cth\u003eOption \/ Segment\u003c\/th\u003e\n      \u003cth\u003eCode on This SKU\u003c\/th\u003e\n      \u003cth\u003eDescription\u003c\/th\u003e\n    \u003c\/tr\u003e\n  \u003c\/thead\u003e\n  \u003ctbody\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eOrderable Part Number\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e\u003cstrong\u003e330703-000-040-10-02-00\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e3300 XL 11 mm Probe, M14 x 1.5 thread, without armor\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eA - Unthreaded Length Option\u003c\/td\u003e\n      \u003ctd\u003e000\u003c\/td\u003e\n      \u003ctd\u003e0 mm unthreaded length\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eB - Overall Case Length Option\u003c\/td\u003e\n      \u003ctd\u003e040\u003c\/td\u003e\n      \u003ctd\u003e40 mm overall case length (ordered in increments of 2 mm)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eC - Total Length Option\u003c\/td\u003e\n      \u003ctd\u003e10\u003c\/td\u003e\n      \u003ctd\u003e1.0 meter (3.3 feet) probe length\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eD - Connector and Cable-Type Option\u003c\/td\u003e\n      \u003ctd\u003e02\u003c\/td\u003e\n      \u003ctd\u003eMiniature coaxial ClickLoc connector, standard cable\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eE - Agency Approval Option\u003c\/td\u003e\n      \u003ctd\u003e00\u003c\/td\u003e\n      \u003ctd\u003eNo agency approvals required\u003c\/td\u003e\n    \u003c\/tr\u003e\n  \u003c\/tbody\u003e\n\u003c\/table\u003e\n\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003ctable\u003e\n  \u003cthead\u003e\n    \u003ctr\u003e\n      \u003cth\u003eParameter\u003c\/th\u003e\n      \u003cth\u003eSpecification Value\u003c\/th\u003e\n    \u003c\/tr\u003e\n  \u003c\/thead\u003e\n  \u003ctbody\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eManufacturer\u003c\/td\u003e\n      \u003ctd\u003eBently Nevada (Baker Hughes)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eModel \/ Part Number\u003c\/td\u003e\n      \u003ctd\u003e330703-000-040-10-02-00\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eTransducer System\u003c\/td\u003e\n      \u003ctd\u003e3300 XL 11 mm Proximity Transducer System\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eThread Type\u003c\/td\u003e\n      \u003ctd\u003eMetric M14 x 1.5 thread\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eArmor Option\u003c\/td\u003e\n      \u003ctd\u003eWithout armor (unarmored)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eUnthreaded Length\u003c\/td\u003e\n      \u003ctd\u003e0 mm\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eOverall Case Length\u003c\/td\u003e\n      \u003ctd\u003e40 mm\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eProbe Total Length\u003c\/td\u003e\n      \u003ctd\u003e1.0 meter (3.3 feet)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eLinear Range\u003c\/td\u003e\n      \u003ctd\u003e4.0 mm (160 mils), from approximately 0.5 mm to 4.5 mm (20 to 180 mils)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eRecommended Gap Setting\u003c\/td\u003e\n      \u003ctd\u003e2.5 mm (100 mils)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eIncremental Scale Factor (ISF)\u003c\/td\u003e\n      \u003ctd\u003e3.94 V\/mm (100 mV\/mil) nominal\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eDeviation from Straight Line (DSL)\u003c\/td\u003e\n      \u003ctd\u003eLess than +\/- 0.10 mm (+\/- 4 mils) over linear range\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eFrequency Response\u003c\/td\u003e\n      \u003ctd\u003e0 to 8 kHz (+0, -3 dB typical)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eProbe dc Resistance (R_PROBE)\u003c\/td\u003e\n      \u003ctd\u003e5.9 +\/- 0.5 ohms (between center and outer conductor)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eProbe Tip Material\u003c\/td\u003e\n      \u003ctd\u003ePolyphenylene sulfide (PPS)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eProbe Case Material\u003c\/td\u003e\n      \u003ctd\u003eAISI 304 stainless steel (SST)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eProbe Cable Specification\u003c\/td\u003e\n      \u003ctd\u003e75 Ohm triaxial, fluoroethylene propylene (FEP) insulated\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eConnector Type\u003c\/td\u003e\n      \u003ctd\u003eMiniature coaxial ClickLoc connector\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eConnector Material\u003c\/td\u003e\n      \u003ctd\u003eGold-plated brass\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eMaximum Case Torque\u003c\/td\u003e\n      \u003ctd\u003e63.3 N-m (560 in-lb)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eRecommended Case Torque\u003c\/td\u003e\n      \u003ctd\u003e21.1 N-m (187 in-lb)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eMaximum Rated Tensile Strength\u003c\/td\u003e\n      \u003ctd\u003e330 N (75 lb) probe case to lead; 270 N (60 lb) at connector joint\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eMinimum Cable Bend Radius\u003c\/td\u003e\n      \u003ctd\u003e25.4 mm (1.0 in)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eOperating and Storage Temperature\u003c\/td\u003e\n      \u003ctd\u003e-52 degC to +177 degC (-62 degF to +351 degF)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eRelative Humidity\u003c\/td\u003e\n      \u003ctd\u003e100% condensing, non-submersible (with protected connectors)\u003c\/td\u003e\n    \u003c\/tr\u003e\n  \u003c\/tbody\u003e\n\u003c\/table\u003e\n\n\u003ch3\u003eConnections and Interfaces\u003c\/h3\u003e\n\u003ctable\u003e\n  \u003cthead\u003e\n    \u003ctr\u003e\n      \u003cth\u003eConnection Interface\u003c\/th\u003e\n      \u003cth\u003eDescription\u003c\/th\u003e\n    \u003c\/tr\u003e\n  \u003c\/thead\u003e\n  \u003ctbody\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eCenter Conductor\u003c\/td\u003e\n      \u003ctd\u003eSignal core (coaxial probe output)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eOuter Conductor\u003c\/td\u003e\n      \u003ctd\u003eShield \/ Return path\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eConnector Type\u003c\/td\u003e\n      \u003ctd\u003eMale miniature ClickLoc coaxial connector\u003c\/td\u003e\n    \u003c\/tr\u003e\n  \u003c\/tbody\u003e\n\u003c\/table\u003e\n\n\u003ch3\u003eInstallation Guidelines\u003c\/h3\u003e\n\u003cp\u003eTo establish successful physical and electrical installation of the 3300 XL 11 mm proximity probe, observe the following engineering guidelines:\u003c\/p\u003e\n\u003cul\u003e\n  \u003cli\u003eMaintain a minimum bend radius of 25.4 mm (1.0 in) on all triaxial cables to prevent impedance mismatch and core breakage.\u003c\/li\u003e\n  \u003cli\u003eWhen tightening the M14 x 1.5 threaded probe case, do not exceed the maximum rated torque of 63.3 N-m (560 in-lb). The recommended mounting torque is 21.1 N-m (187 in-lb).\u003c\/li\u003e\n  \u003cli\u003eEnsure the total physical length of the probe and extension cable matches the calibrated system length (5.0 meters or 9.0 meters) specified by the Proximitor sensor. For this 1.0-meter probe, pair with a 4.0-meter extension cable for a 5.0-meter system, or an 8.0-meter extension cable for a 9.0-meter system.\u003c\/li\u003e\n  \u003cli\u003eProtect the ClickLoc coaxial connection using connector protectors or self-fusing silicone tape in environments where the cable joins will be exposed to turbine oil or liquids.\u003c\/li\u003e\n  \u003cli\u003eAvoid exceeding the thread engagement limits to prevent binding during installation.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eCompliance and Certifications\u003c\/h3\u003e\n\u003cp\u003eThis specific configuration (Option 00) does not require hazardous area agency certifications. For applications requiring ATEX, IECEx, or North American hazardous area approvals, select configurations ending in Option 05.\u003c\/p\u003e","brand":"Bently Nevada","offers":[{"title":"Default Title","offer_id":52666867089771,"sku":"330703-000-040-10-02-00","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/3227\/0443\/files\/bently-nevada-330703-000-040-10-02-00-proximity-probe-fak3v0fd0oh_0de8690a-800e-471c-bce5-4f60219c789d.jpg?v=1765449493","url":"https:\/\/www.plcprotech.com\/products\/bently-nevada-330703-000-040-10-02-00-3300-xl-11-mm-proximity-probe","provider":"PLC ProTech Ltd.","version":"1.0","type":"link"}