{"product_id":"bently-nevada-330730-080-03-05-3300-xl-11-mm-extension-cable","title":"Bently Nevada 330730-080-03-05 3300 XL 11 mm Extension Cable","description":"\u003ch3\u003eDescription\u003c\/h3\u003e\n\u003cp\u003eOption 080 (8.0 meters length), Option 03 (armored cable with connector protector), and Option 05 (multiple agency approvals) specify the configuration of this \u003cstrong\u003e3300 XL 11 mm Extension Cable\u003c\/strong\u003e — \u003cstrong\u003e330730-080-03-05\u003c\/strong\u003e.\u003c\/p\u003e\n\u003cp\u003eThis cable configuration features an integrated FEP-coated stainless steel armor jacket that provides physical protection in abrasive industrial environments. The miniature coaxial ClickLoc connectors are equipped with fluorosilicone connector protectors to shield the electrical connection from moisture, dust, and turbine oil. Operating as an electrical bridge within the 3300 XL 11 mm transducer system, it provides a precise 75 ohm coaxial pathway for high-frequency signal transmission between the proximity probe and the Proximitor sensor.\u003c\/p\u003e\n\n\u003ch3\u003eFeatures\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003e8.0 Meter Length\u003c\/strong\u003e: Designed specifically to achieve the proper calibration distance within 9.0 meter system configurations when paired with a 1.0 meter proximity probe.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eFEP-Coated Armor\u003c\/strong\u003e: Covered in a stainless steel armor jacket with a protective FEP outer wrap to resist mechanical wear and physical impact.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eConnector Protectors\u003c\/strong\u003e: Pre-installed fluorosilicone boots guard male and female connections against fluid ingress and accidental disconnects.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eStandard Coaxial Design\u003c\/strong\u003e: Features a nominal 75 ohm characteristic impedance to maintain signal integrity without attenuation or phase distortion.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eHazardous Area Rating\u003c\/strong\u003e: Configured with multiple global approvals suitable for deployment in zones requiring intrinsic safety or non-incendive parameters.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eApplications\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eTurbine and compressor shaft vibration and axial position monitoring.\u003c\/li\u003e\n\u003cli\u003eRamp differential expansion measurements on industrial steam turbines.\u003c\/li\u003e\n\u003cli\u003eRod position or rod drop detection on reciprocating compressors.\u003c\/li\u003e\n\u003cli\u003eTachometer, phase reference (Keyphasor), and zero speed sensing applications.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eOrdering Information\u003c\/h3\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003eOption Segment\u003c\/th\u003e\n\u003cth\u003eSelected Code\u003c\/th\u003e\n\u003cth\u003eDescription \/ Parameter Meaning\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBase Model\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e330730\u003c\/td\u003e\n\u003ctd\u003e3300 XL 11 mm Extension Cable\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eA - Cable Length Option\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e080\u003c\/td\u003e\n\u003ctd\u003e8.0 meters (26.2 feet)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eB - Connector and Cable Option\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e03\u003c\/td\u003e\n\u003ctd\u003eArmored cable with connector protector\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eC - Agency Approval Option\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e05\u003c\/td\u003e\n\u003ctd\u003eMultiple Approvals (CSA, ATEX, IECEx)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003eParameter\u003c\/th\u003e\n\u003cth\u003eSpecification Value\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eManufacturer\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eBently Nevada (Baker Hughes)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePart Number\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e330730-080-03-05\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eTransducer System Compatibility\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e3300 XL 11 mm Proximity Transducer System\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eTotal Cable Length\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e8.0 meters (26.2 feet)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCable Impedance\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e75 ohms (nominal)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eArmor Construction\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eFEP-coated stainless steel armor\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eArmor Maximum Outer Diameter\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e7.6 mm (0.30 in)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCoaxial Cable Outer Diameter\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e3.7 mm (0.15 in) maximum\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eConnector Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eMiniature coaxial ClickLoc (coaxial conductor to coaxial conductor)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eConnector Material\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eGold-plated brass with fluorosilicone protector boot\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eConductor DC Resistance (Rjacket)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e2.0 +\/- 0.5 ohms (coaxial conductor to coaxial conductor)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eConductor DC Resistance (Rcore)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0.6 +\/- 0.2 ohms (center conductor to center conductor)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCable Capacitance\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e69.9 pF\/m (21.3 pF\/ft) typical\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOperating and Storage Temperature\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e-52 degC to +177 degC (-62 degF to +351 degF)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRelative Humidity\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e100% condensing, non-submersible (when connectors are protected)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCable Weight (Armored)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e140 g\/m (1.5 oz\/ft)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\n\u003ch3\u003eInstallation Guidelines\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eSystem Length Matching\u003c\/strong\u003e: Ensure that the sum of the extension cable length (8.0 meters) and the probe length (1.0 meter) matches the calibrated length of the 9.0 meter Proximitor sensor.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eBending Radius\u003c\/strong\u003e: Do not bend the armored cable below the recommended minimum bend radius of 30.5 mm (1.2 in) to avoid damaging the internal coaxial core.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eConnector Handling\u003c\/strong\u003e: Keep connectors dry and clean during installation. Only use approved, residue-free contact cleaners if cleaning is necessary.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eConnector Protection\u003c\/strong\u003e: Fully slide the pre-installed fluorosilicone connector protectors over the junction to seal it. Do not apply silicone tape if the connection will be exposed to turbine oils.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eCompliance and Certifications\u003c\/h3\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003eCertification Authority\u003c\/th\u003e\n\u003cth\u003eApproval Classification\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eATEX \/ IECEx (ia)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eEx ia IIC T5...T1 Ga; Ex ia IIIC T90 degC...T280 degC Dc (for EPL Dc)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eATEX \/ IECEx (nA, ec)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eEx nA IIC T5...T1 Gc; Ex ec IIC T5...T1 Gc\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eNorth America (cNRTLus - ia)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eClass I, Zone 0, AEx\/Ex ia IIC T5...T1 Ga; Class I, Div 1, Groups A, B, C, D; Class II, Groups E, F, G; Class III\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eNorth America (cNRTLus - nA, ec)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eClass I, Zone 2, AEx\/Ex nA IIC T4\/T5 Gc; Class I, Zone 2, AEx\/Ex ec IIC T4\/T5 Gc; Class I, Div 2, Groups A, B, C, D\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eEuropean Directive Compliance\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eCE Mark, EMC Directive 2014\/30\/EU, RoHS Directive 2011\/65\/EU\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e","brand":"Bently Nevada","offers":[{"title":"Default Title","offer_id":52666645053803,"sku":"330730-080-03-05","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/3227\/0443\/files\/bently-nevada-330730-080-03-05-3300-xl-11-mm-extension-cable-zfienoolwid_c50f535e-db24-4e1c-ae22-9194756c4887.jpg?v=1765444602","url":"https:\/\/www.plcprotech.com\/products\/bently-nevada-330730-080-03-05-3300-xl-11-mm-extension-cable","provider":"PLC ProTech Ltd.","version":"1.0","type":"link"}