{"product_id":"bently-nevada-330878-90-cn-3300-xl-50-mm-proximitor-sensor","title":"Bently Nevada 330878-90-CN 3300 XL 50 mm Proximitor Sensor","description":"\u003ch3\u003eDescription\u003c\/h3\u003e\n\u003cp style=\"color: #2d3748; margin-bottom: 1rem;\"\u003eConditioning dynamic eddy current signals for high-reliability machinery diagnostics, the \u003cstrong\u003eBently Nevada 330878-90-CN\u003c\/strong\u003e operates as a key component of the \u003cstrong\u003e3300 XL 50 mm Proximitor Sensor\u003c\/strong\u003e system. This unit converts the radio frequency (RF) signal generated by the proximity probe into a proportional voltage output, enabling precise measurements of shaft displacement, vibration, and position in heavy rotating machinery. The specific \u003cstrong\u003e-90-CN\u003c\/strong\u003e configuration designates a 9.0-meter system length with panel-mounting capability and regional-specific safety certifications.\u003c\/p\u003e\n\n\u003ch3 style=\"color: #1a365d; margin-top: 1.5rem; margin-bottom: 0.5rem;\"\u003eFeatures\u003c\/h3\u003e\n\u003cul style=\"list-style-type: square; color: #2d3748; padding-left: 1.5rem; margin-bottom: 1rem;\"\u003e\n  \u003cli\u003eOptimized for the high-aperture fields of 50 mm proximity probes.\u003c\/li\u003e\n  \u003cli\u003e9.0-meter (29.5 feet) total system length calibration matches probe and extension cable impedance.\u003c\/li\u003e\n  \u003cli\u003eRugged panel-mount design for secure installation within industrial junction boxes or instrument enclosures.\u003c\/li\u003e\n  \u003cli\u003eCorrosion-resistant A380 cast aluminum housing provides superior durability in harsh environments.\u003c\/li\u003e\n  \u003cli\u003eCN agency approval designation for country-specific regulatory compliance.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3 style=\"color: #1a365d; margin-top: 1.5rem; margin-bottom: 0.5rem;\"\u003eApplications\u003c\/h3\u003e\n\u003cul style=\"list-style-type: square; color: #2d3748; padding-left: 1.5rem; margin-bottom: 1rem;\"\u003e\n  \u003cli\u003eThrust and radial vibration monitoring on large utility-scale steam and gas turbines.\u003c\/li\u003e\n  \u003cli\u003eShaft centerline tracking and displacement analysis in hydroelectric generators.\u003c\/li\u003e\n  \u003cli\u003eMechanical protection loops for high-horsepower industrial compressors and process pumps.\u003c\/li\u003e\n  \u003cli\u003eTorsional and structural displacement monitoring in power generation and marine propulsion.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3 style=\"color: #1a365d; margin-top: 1.5rem; margin-bottom: 0.5rem;\"\u003eTechnical Specifications Table\u003c\/h3\u003e\n\u003cdiv style=\"overflow-x: auto; width: 100%; margin-bottom: 1.5rem;\"\u003e\n  \u003ctable style=\"border-collapse: collapse; width: 100%; color: #2d3748; border: 1px solid #e2e8f0;\"\u003e\n    \u003cthead\u003e\n      \u003ctr style=\"border-bottom: 2px solid #2b6cb0;\"\u003e\n        \u003cth style=\"padding: 10px; text-align: left; font-weight: bold;\"\u003eParameter\u003c\/th\u003e\n        \u003cth style=\"padding: 10px; text-align: left; font-weight: bold;\"\u003eSpecification Value\u003c\/th\u003e\n      \u003c\/tr\u003e\n    \u003c\/thead\u003e\n    \u003ctbody\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 10px; font-weight: bold;\"\u003eManufacturer\u003c\/td\u003e\n        \u003ctd style=\"padding: 10px;\"\u003eBently Nevada (Baker Hughes)\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 10px; font-weight: bold;\"\u003eModel Number\u003c\/td\u003e\n        \u003ctd style=\"padding: 10px;\"\u003e330878-90-CN\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 10px; font-weight: bold;\"\u003eSensor Series\u003c\/td\u003e\n        \u003ctd style=\"padding: 10px;\"\u003e3300 XL 50 mm\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 10px; font-weight: bold;\"\u003eSystem Length\u003c\/td\u003e\n        \u003ctd style=\"padding: 10px;\"\u003e9.0 meters (29.5 feet)\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 10px; font-weight: bold;\"\u003eMounting Configuration\u003c\/td\u003e\n        \u003ctd style=\"padding: 10px;\"\u003ePanel Mount\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 10px; font-weight: bold;\"\u003eHousing Material\u003c\/td\u003e\n        \u003ctd style=\"padding: 10px;\"\u003eA380 Aluminum\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 10px; font-weight: bold;\"\u003eOperating Temperature\u003c\/td\u003e\n        \u003ctd style=\"padding: 10px;\"\u003e-51 degC to +100 degC (-60 degF to +212 degF)\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 10px; font-weight: bold;\"\u003eStorage Temperature\u003c\/td\u003e\n        \u003ctd style=\"padding: 10px;\"\u003e-51 degC to +105 degC (-60 degF to +221 degF)\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 10px; font-weight: bold;\"\u003eAgency Approvals\u003c\/td\u003e\n        \u003ctd style=\"padding: 10px;\"\u003eCN (Country Specific Approvals)\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 10px; font-weight: bold;\"\u003eShipping Weight (Calculated)\u003c\/td\u003e\n        \u003ctd style=\"padding: 10px;\"\u003e3.0 kg (6.6 lbs)\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 10px; font-weight: bold;\"\u003eCountry of Origin\u003c\/td\u003e\n        \u003ctd style=\"padding: 10px;\"\u003eUnited States\u003c\/td\u003e\n      \u003c\/tr\u003e\n    \u003c\/tbody\u003e\n  \u003c\/table\u003e\n\u003c\/div\u003e\n\n\u003ch3 style=\"color: #1a365d; margin-top: 1.5rem; margin-bottom: 0.5rem;\"\u003eConnections and Interfaces\u003c\/h3\u003e\n\u003cdiv style=\"overflow-x: auto; width: 100%; margin-bottom: 1.5rem;\"\u003e\n  \u003ctable style=\"border-collapse: collapse; width: 100%; color: #2d3748; border: 1px solid #e2e8f0;\"\u003e\n    \u003cthead\u003e\n      \u003ctr style=\"border-bottom: 2px solid #2b6cb0;\"\u003e\n        \u003cth style=\"padding: 10px; text-align: left; font-weight: bold;\"\u003eTerminal \/ Port\u003c\/th\u003e\n        \u003cth style=\"padding: 10px; text-align: left; font-weight: bold;\"\u003eFunction \/ Circuit Assignment\u003c\/th\u003e\n      \u003c\/tr\u003e\n    \u003c\/thead\u003e\n    \u003ctbody\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 10px; font-weight: bold;\"\u003eCoaxial Jack\u003c\/td\u003e\n        \u003ctd style=\"padding: 10px;\"\u003eAccepts RF cable connection from the 3300 XL 50 mm extension cable \/ probe assembly.\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 10px; font-weight: bold;\"\u003eTerminal VT\u003c\/td\u003e\n        \u003ctd style=\"padding: 10px;\"\u003ePower input supply (-24 Vdc nominal).\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 10px; font-weight: bold;\"\u003eTerminal OUT\u003c\/td\u003e\n        \u003ctd style=\"padding: 10px;\"\u003eDynamic output voltage signal (proportional to target distance).\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"border-bottom: 1px solid #e2e8f0;\"\u003e\n        \u003ctd style=\"padding: 10px; font-weight: bold;\"\u003eTerminal COM\u003c\/td\u003e\n        \u003ctd style=\"padding: 10px;\"\u003eCommon ground reference.\u003c\/td\u003e\n      \u003c\/tr\u003e\n    \u003c\/tbody\u003e\n  \u003c\/table\u003e\n\u003c\/div\u003e\n\n\u003ch3 style=\"color: #1a365d; margin-top: 1.5rem; margin-bottom: 0.5rem;\"\u003eAlternative Models \u0026amp; Compatibility\u003c\/h3\u003e\n\u003cp style=\"color: #2d3748; margin-bottom: 1rem;\"\u003eThe 330878-90-CN must only be paired with 3300 XL 50 mm proximity probes and equivalent 9.0-meter matching systems. It is not interchangeable with 8 mm or 11 mm Proximitor sensors, as the internal oscillators and linearization curves are explicitly tuned for the electromagnetic footprint of the large 50 mm probe head. Intermixing components across different millimeter-scale families will lead to severe calibration drift and false machine trip signals.\u003c\/p\u003e\n\n\u003ch3 style=\"color: #1a365d; margin-top: 1.5rem; margin-bottom: 0.5rem;\"\u003eApplication Pitfalls \u0026amp; Engineering Notes\u003c\/h3\u003e\n\u003cp style=\"color: #2d3748; margin-bottom: 1rem;\"\u003eThe 50 mm sensor system generates a broad electromagnetic field. Ensure that a clear, unobstructed side-clearance zone is maintained around the probe head to prevent parasitic targets (such as machine casing walls or internal brackets) from entering the detection field. Operating outside the rated temperature envelope (-51 degC to +100 degC) will degrade the sensor's temperature compensation circuitry, introducing measurement offset errors.\u003c\/p\u003e\n\n\u003ch3 style=\"color: #1a365d; margin-top: 1.5rem; margin-bottom: 0.5rem;\"\u003eCommissioning \u0026amp; Wiring Tips\u003c\/h3\u003e\n\u003cp style=\"color: #2d3748; margin-bottom: 1rem;\"\u003eAlways check the coaxial connector insulation prior to startup. The outer connector sleeve must be kept completely isolated from the machine ground; utilize Bently Nevada connector protectors or silicone heat-shrink tubing over the coaxial junctions. For signal integrity, route field wiring inside dedicated, grounded conduit, keeping it physically separated from high-voltage motor supply runs to minimize electromagnetic interference.\u003c\/p\u003e\n\n\u003ch3 style=\"color: #1a365d; margin-top: 1.5rem; margin-bottom: 0.5rem;\"\u003eInstallation Guidelines\u003c\/h3\u003e\n\u003cdiv style=\"background-color: #fff5f5; border-left: 4px solid #c53030; padding: 1rem; margin-bottom: 1.5rem; border-radius: 4px;\"\u003e\n  \u003cstrong style=\"color: #9b2c2c; display: block; margin-bottom: 0.5rem;\"\u003eCRITICAL WARNING\u003c\/strong\u003e\n  \u003cp style=\"color: #9b2c2c; margin: 0;\"\u003eIsolate and lock out all external power sources before handling terminal block wiring. Failure to de-energize active monitoring systems prior to connection can introduce electrical transients that may cause damage to the monitoring rack input cards or trigger spurious turbine emergency trips.\u003c\/p\u003e\n\u003c\/div\u003e\n\n\u003cdiv style=\"display: flex; flex-direction: column; gap: 1rem; margin-bottom: 1.5rem;\"\u003e\n  \u003cdiv style=\"display: flex; align-items: flex-start; gap: 1rem;\"\u003e\n    \u003cdiv style=\"background-color: #2b6cb0; color: #ffffff; width: 28px; height: 28px; border-radius: 50%; display: flex; align-items: center; justify-content: center; font-weight: bold; flex-shrink: 0;\"\u003e1\u003c\/div\u003e\n    \u003cp style=\"color: #2d3748; margin: 0; padding-top: 2px;\"\u003eMount the Proximitor housing securely on the subpanel using the integrated mounting flanges. Ensure the mounting plate has a solid path to the structural instrument ground.\u003c\/p\u003e\n  \u003c\/div\u003e\n  \u003cdiv style=\"display: flex; align-items: flex-start; gap: 1rem;\"\u003e\n    \u003cdiv style=\"background-color: #2b6cb0; color: #ffffff; width: 28px; height: 28px; border-radius: 50%; display: flex; align-items: center; justify-content: center; font-weight: bold; flex-shrink: 0;\"\u003e2\u003c\/div\u003e\n    \u003cp style=\"color: #2d3748; margin: 0; padding-top: 2px;\"\u003eConnect the 9.0-meter extension cable coaxial plug to the sensor's coaxial jack. Hand-tighten the connector and ensure the mechanical locking mechanism is secure.\u003c\/p\u003e\n  \u003c\/div\u003e\n  \u003cdiv style=\"display: flex; align-items: flex-start; gap: 1rem;\"\u003e\n    \u003cdiv style=\"background-color: #2b6cb0; color: #ffffff; width: 28px; height: 28px; border-radius: 50%; display: flex; align-items: center; justify-content: center; font-weight: bold; flex-shrink: 0;\"\u003e3\u003c\/div\u003e\n    \u003cp style=\"color: #2d3748; margin: 0; padding-top: 2px;\"\u003eInstall three-wire shielded instrument cabling to the VT, OUT, and COM screw terminals, maintaining proper torque to prevent loose terminations.\u003c\/p\u003e\n  \u003c\/div\u003e\n  \u003cdiv style=\"display: flex; align-items: flex-start; gap: 1rem;\"\u003e\n    \u003cdiv style=\"background-color: #2b6cb0; color: #ffffff; width: 28px; height: 28px; border-radius: 50%; display: flex; align-items: center; justify-content: center; font-weight: bold; flex-shrink: 0;\"\u003e4\u003c\/div\u003e\n    \u003cp style=\"color: #2d3748; margin: 0; padding-top: 2px;\"\u003eGround the cable shield exclusively at the monitor rack\/safety barrier end; do not connect the shield to ground at the Proximitor sensor terminal block to avoid ground loops.\u003c\/p\u003e\n  \u003c\/div\u003e\n\u003c\/div\u003e","brand":"Bently Nevada","offers":[{"title":"Default Title","offer_id":52668278473067,"sku":"330878-90-CN","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/3227\/0443\/files\/330878-90-CN-unerfnsu24n_b756110a-c434-49a9-82f1-7fdd925fec47.jpg?v=1765520332","url":"https:\/\/www.plcprotech.com\/products\/bently-nevada-330878-90-cn-3300-xl-50-mm-proximitor-sensor","provider":"PLC ProTech Ltd.","version":"1.0","type":"link"}