{"product_id":"bently-nevada-330881-28-04-080-03-02-proxpac-xl-proximity-transducer","title":"Bently Nevada 330881-28-04-080-03-02 PROXPAC XL Proximity Transducer","description":"\u003ch3\u003eDescription\u003c\/h3\u003e\n\u003cp\u003eOption 28 (3300 XL 8 mm probe with multiple approvals) and Option 04 (40 mm standoff adapter) define the specific physical profile of this metric \u003cstrong\u003e330881-28-04-080-03-02\u003c\/strong\u003e integrated transducer assembly. By packaging both the 3300 XL 8 mm proximity probe and the Proximitor sensor into a single, self-contained protective housing, this configuration eliminates the requirement for an external extension cable and separate Proximitor junction box. The field wiring connects directly from the monitoring system to the integrated terminal strip inside the housing, greatly simplifying installation and reducing mechanical failure points.\u003c\/p\u003e\n\n\u003cp\u003eThe 330881-28-04-080-03-02 features a robust housing constructed of glass-reinforced polyphenylene sulfide (PPS) thermoplastic with integrated conductive fibers. This advanced material effectively dissipates electrostatic charges and delivers exceptional chemical resistance in severe operating environments. Rated for Type 4X and IP66 sealing, the housing defends internal electronics against dust, moisture, and low-pressure water jets, making it suitable for hazardous area deployment and critical rotating machinery protection.\u003c\/p\u003e\n\n\u003ch3\u003eFeatures\u003c\/h3\u003e\n\u003cul\u003e\n  \u003cli\u003eOption 28 integrated 3300 XL 8 mm proximity probe pre-installed with multiple international safety certifications.\u003c\/li\u003e\n  \u003cli\u003eOption 04 provides a 40 mm metric standoff adapter (B dimension) for precise axial adjustments.\u003c\/li\u003e\n  \u003cli\u003eOption 080 specifies an 80 mm probe penetration length (C dimension) inside the stainless steel sleeve.\u003c\/li\u003e\n  \u003cli\u003eOption 03 supplies one M20 fitting and two plugs to streamline robust field wiring connections.\u003c\/li\u003e\n  \u003cli\u003eOption 02 utilizes a 3\/4-14 NPT mounting thread, providing secure mechanical attachment for standoff-configured applications.\u003c\/li\u003e\n  \u003cli\u003eAdvanced PPS thermoplastic housing containing glass and conductive fibers provides Type 4X and IP66 ingress protection.\u003c\/li\u003e\n  \u003cli\u003eSelf-contained design eliminates intermediate extension cables and dedicated proximity sensor enclosures.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eApplications\u003c\/h3\u003e\n\u003cul\u003e\n  \u003cli\u003eContinuous radial vibration and axial position monitoring on utility turbines and industrial gearboxes.\u003c\/li\u003e\n  \u003cli\u003eMachinery protection inside hazardous locations requiring ATEX, IECEx, and North American certifications.\u003c\/li\u003e\n  \u003cli\u003eSevere environmental installations exposed to chemical spray, condensing humidity, or ambient moisture.\u003c\/li\u003e\n  \u003cli\u003eSimplified field installations where minimizing external terminal boxes and conduit runs is a priority.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eOrdering Information\u003c\/h3\u003e\n\u003ctable\u003e\n  \u003cthead\u003e\n    \u003ctr\u003e\n      \u003cth\u003eOption \/ Segment\u003c\/th\u003e\n      \u003cth\u003eCode on This SKU\u003c\/th\u003e\n      \u003cth\u003eDescription and Meaning\u003c\/th\u003e\n    \u003c\/tr\u003e\n  \u003c\/thead\u003e\n  \u003ctbody\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eBase Model\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e330881\u003c\/td\u003e\n      \u003ctd\u003ePROXPAC XL Proximity Transducer, Metric\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eA - Probe and Approvals Option\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e28\u003c\/td\u003e\n      \u003ctd\u003e3300 XL 8 mm probe with Multiple Approvals\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eB - Standoff Adapter Option\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e04\u003c\/td\u003e\n      \u003ctd\u003e40 mm standoff adapter length (B Dimension)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eC - Probe Penetration Option\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e080\u003c\/td\u003e\n      \u003ctd\u003e80 mm probe penetration length (C Dimension)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eD - Fittings Option\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e03\u003c\/td\u003e\n      \u003ctd\u003eOne M20 fitting, two plugs\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eE - Mounting Thread Option\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e02\u003c\/td\u003e\n      \u003ctd\u003e3\/4-14 NPT (required for Standoff Adapter configuration)\u003c\/td\u003e\n    \u003c\/tr\u003e\n  \u003c\/tbody\u003e\n\u003c\/table\u003e\n\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003ctable\u003e\n  \u003ctbody\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eManufacturer\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003eBently Nevada (Baker Hughes)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eModel Series\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003ePROXPAC XL (33088)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eInput Probe Type\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e3300 XL 8 mm Proximity Probe with 1-meter cable\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003ePower Requirements\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003eRequires -17.5 Vdc to -26 Vdc at 12 mA maximum (without barriers)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eLinear Range\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e2.0 mm (80 mils) nominal\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eScale Factor\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e7.87 V\/mm (200 mV\/mil) nominal\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eFrequency Response\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e0 to 10 kHz: +0, -3 dB (verified with up to 305 meters of field wiring)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eMinimum Target Size\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e15.2 mm (0.6 in) diameter (flat target)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eMinimum Shaft Diameter\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e50.8 mm (2.0 in)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eHousing Material\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003eUltraviolet (UV) resistant, glass-reinforced polyphenylene sulfide (PPS) thermoplastic with conductive fibers\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eSleeve and Retaining Chain\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003eAISI 304 stainless steel\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eOuter Sleeve and Retaining Screws\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003eAISI 303 stainless steel\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eSleeve O-Ring Material\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003eNeoprene\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eProbe Operating Temperature\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e-52 degC to +177 degC (-62 degF to +351 degF)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eHousing Operating Temperature\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e-52 degC to +100 degC (-62 degF to +212 degF)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eStorage Temperature\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e-52 degC to +105 degC (-62 degF to +221 degF)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eHumidity Limits\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e100% condensing, non-submersible when connectors are protected\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eIngress Protection Rating\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003eType 4X and IP66\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eHousing Impact Strength\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003eWithstands two separate 4 Joule impacts at -39 degC and at 115 degC (certified by BASEEFA)\u003c\/td\u003e\n    \u003c\/tr\u003e\n  \u003c\/tbody\u003e\n\u003c\/table\u003e\n\n\u003ch3\u003eInstallation Guidelines\u003c\/h3\u003e\n\u003cul\u003e\n  \u003cli\u003eVerify that the total B plus C dimensions do not exceed 305 mm (12.0 in) without additional sleeve support near the probe to prevent mechanical resonance.\u003c\/li\u003e\n  \u003cli\u003eEnsure all field wiring terminals inside the housing are clean and dry before securing the cover to maintain IP66 and Type 4X ratings.\u003c\/li\u003e\n  \u003cli\u003eUse a high-quality thread sealant on the 3\/4-14 NPT mounting threads (Option 02) to maintain a robust environmental seal with the machine case.\u003c\/li\u003e\n  \u003cli\u003eRoute field cabling through the provided M20 fitting (Option 03), installing a cable gland or conduit seal to prevent external moisture from traveling into the housing.\u003c\/li\u003e\n  \u003cli\u003eSet the initial probe physical gap at the electrical center of the linear range to ensure proper scale factor accuracy.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eCompliance and Certifications\u003c\/h3\u003e\n\u003cul\u003e\n  \u003cli\u003e\n\u003cstrong\u003eATEX\/IECEx:\u003c\/strong\u003e Ex ia IIC T4\/T5 Ga, Ex ia IIIC T90C\/T105C Dc (with appropriate intrinsic safety barriers)\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003ecNRTLus:\u003c\/strong\u003e Class I, Zone 0: AEx\/Ex ia IIC T4\/T5 Ga; Class I, Division 1, Groups A, B, C, D; Class II, Groups E, F, G; Class III\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eZone 2 \/ Division 2:\u003c\/strong\u003e Ex nA IIC T4\/T5 Gc, Ex ec IIC T4\/T5 Gc; Class I, Division 2, Groups A, B, C, D\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eCE Mark:\u003c\/strong\u003e Complies with European Union electromagnetic and environmental safety requirements\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Bently Nevada","offers":[{"title":"Default Title","offer_id":52666619232619,"sku":"330881-28-04-080-03-02","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/3227\/0443\/files\/bently-nevada-330881-28-04-080-03-02-proxpac-xl-proximity-transducer-gxpdkxrtiek_f01666ca-0d92-4196-a86b-503ec780351f.jpg?v=1765444236","url":"https:\/\/www.plcprotech.com\/products\/bently-nevada-330881-28-04-080-03-02-proxpac-xl-proximity-transducer","provider":"PLC ProTech Ltd.","version":"1.0","type":"link"}