{"product_id":"bently-nevada-330881-28-05-090-00-02-proxpac-xl-integrated-proximity-transducer","title":"Bently Nevada 330881-28-05-090-00-02 PROXPAC XL Integrated Proximity Transducer","description":"\u003ch3\u003eDescription\u003c\/h3\u003e\nThe \u003cstrong\u003e330881-28-05-090-00-02\u003c\/strong\u003e is a \u003cstrong\u003ePROXPAC XL Integrated Proximity Transducer\u003c\/strong\u003e assembly designed to provide a self-contained vibration and position monitoring solution. This unit integrates the 3300 XL 8 mm proximity probe and the Proximitor sensor into a single, robust PPS (Polyphenylene Sulfide) housing, eliminating the need for external extension cables and separate Proximitor housings. This configuration (Option 28 for probe\/approvals, Option 05 for 50 mm standoff, Option 090 for 90 mm probe penetration, Option 00 for no conduit fittings, and Option 02 for 3\/4-14 NPT mounting thread) streamlines installation in severe industrial environments.\n\nBy utilizing a compact, integrated design, the 330881 series simplifies field wiring, as the assembly connects directly to monitoring systems. The housing material incorporates glass and conductive fibers to strengthen the structure and dissipate electrostatic charges. Rated for Type 4X and IP66 protection, this transducer is suited for critical machinery protection where reducing wiring complexity and improving resistance to harsh conditions is required.\n\n\u003ch3\u003eFeatures\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eOption 28:\u003c\/strong\u003e 3300 XL 8 mm proximity probe included with Multiple Approvals.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eOption 05:\u003c\/strong\u003e 50 mm standoff adapter length.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eOption 090:\u003c\/strong\u003e 90 mm probe penetration length.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eOption 00:\u003c\/strong\u003e No conduit fittings; includes two plugs and two washers.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eOption 02:\u003c\/strong\u003e 3\/4-14 NPT mounting thread.\u003c\/li\u003e\n\u003cli\u003eIntegrated Proximitor sensor eliminates separate housing and extension cable requirements.\u003c\/li\u003e\n\u003cli\u003ePolyphenylene Sulfide (PPS) housing with glass and conductive fibers for electrostatic dissipation.\u003c\/li\u003e\n\u003cli\u003eEnvironmental rating: Type 4X and IP66.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eApplications\u003c\/h3\u003e\nTypical applications include machinery protection and condition monitoring in oil and gas, power generation, and petrochemical industries. The PROXPAC XL is ideal for:\n\u003cul\u003e\n\u003cli\u003eShaft vibration and axial position measurement on rotating machinery.\u003c\/li\u003e\n\u003cli\u003eEnvironments where reduced wiring complexity and high-integrity housing are essential.\u003c\/li\u003e\n\u003cli\u003eRetrofitting existing installations where space for separate Proximitor sensors is limited.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eOrdering Information\u003c\/h3\u003e\n\u003ctable\u003e\n\u003ctr\u003e\n\u003cth\u003eOption\u003c\/th\u003e\n\u003cth\u003eCode\u003c\/th\u003e\n\u003cth\u003eDescription\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOrderable Part Number\u003c\/td\u003e\n\u003ctd\u003e330881-28-05-090-00-02\u003c\/td\u003e\n\u003ctd\u003ePROXPAC XL Proximity Transducer Assembly\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eA - Probe\/Approvals\u003c\/td\u003e\n\u003ctd\u003e28\u003c\/td\u003e\n\u003ctd\u003e3300 XL 8 mm probe with Multiple Approvals\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eB - Standoff Adapter\u003c\/td\u003e\n\u003ctd\u003e05\u003c\/td\u003e\n\u003ctd\u003e50 mm length\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eC - Probe Penetration\u003c\/td\u003e\n\u003ctd\u003e090\u003c\/td\u003e\n\u003ctd\u003e90 mm length\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eD - Fittings\u003c\/td\u003e\n\u003ctd\u003e00\u003c\/td\u003e\n\u003ctd\u003eNo fittings; two plugs and two washers\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eE - Mounting Thread\u003c\/td\u003e\n\u003ctd\u003e02\u003c\/td\u003e\n\u003ctd\u003e3\/4-14 NPT\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\n\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003ctable\u003e\n\u003ctr\u003e\n\u003cth\u003eParameter\u003c\/th\u003e\n\u003cth\u003eSpecification\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eManufacturer\u003c\/td\u003e\n\u003ctd\u003eBently Nevada\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePart Number\u003c\/td\u003e\n\u003ctd\u003e330881-28-05-090-00-02\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSystem Type\u003c\/td\u003e\n\u003ctd\u003ePROXPAC XL Proximity Transducer\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProbe Type\u003c\/td\u003e\n\u003ctd\u003e3300 XL 8 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHousing Material\u003c\/td\u003e\n\u003ctd\u003ePolyphenylene Sulfide (PPS)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEnvironmental Rating\u003c\/td\u003e\n\u003ctd\u003eType 4X, IP66\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInput Voltage\u003c\/td\u003e\n\u003ctd\u003e-17.5 Vdc to -26 Vdc\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eLinear Range\u003c\/td\u003e\n\u003ctd\u003e2 mm (80 mils)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOutput Resistance\u003c\/td\u003e\n\u003ctd\u003e50 Ohm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAgency Approvals\u003c\/td\u003e\n\u003ctd\u003eMultiple Approvals (refer to datasheet 178554)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\n\n\u003ch3\u003eInstallation Guidelines\u003c\/h3\u003e\nEnsure the assembly is installed with the correct torque on the 3\/4-14 NPT mounting thread. The PROXPAC XL housing design requires no external extension cables, but field wiring to the monitor should utilize 3-conductor shielded triax cable (1.0 mm2 \/ 18 AWG). When installing in hazardous areas, ensure the wiring meets the requirements specified in the hazardous area drawings (refer to Bently Nevada documentation 140979 or 141092). Maintain proper gap setting (nominal 1.27 mm \/ 50 mils) between the probe tip and the target.","brand":"Bently Nevada","offers":[{"title":"Default Title","offer_id":52666533839211,"sku":"330881-28-05-090-00-02","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/3227\/0443\/files\/bently-nevada-330881-28-05-090-00-02-proxpac-xl-housing-ojx0pfhecnu_560afd8d-88b1-4fe7-991f-c53233207888.jpg?v=1765440392","url":"https:\/\/www.plcprotech.com\/products\/bently-nevada-330881-28-05-090-00-02-proxpac-xl-integrated-proximity-transducer","provider":"PLC ProTech Ltd.","version":"1.0","type":"link"}