{"product_id":"bently-nevada-330881-28-10-100-03-02-proxpac-xl-proximity-transducer","title":"Bently Nevada 330881-28-10-100-03-02 PROXPAC XL Proximity Transducer","description":"\u003ch3\u003eDescription\u003c\/h3\u003e\n\u003cp\u003eOption 28 (3300 XL 8 mm probe with Multiple Approvals) and Option 10 (100 mm standoff adapter) specify the configuration for this PROXPAC XL Proximity Transducer — \u003cstrong\u003e330881-28-10-100-03-02\u003c\/strong\u003e.\u003c\/p\u003e\n\n\u003cp\u003eThe \u003cstrong\u003e330881-28-10-100-03-02\u003c\/strong\u003e integrates a 3300 XL 8 mm proximity probe and its matching Proximitor sensor directly into a single, compact polyphenylene sulfide (PPS) thermoplastic housing assembly. By combining the probe and Proximitor in one structure, this assembly removes the requirement for an external extension cable and separate Proximitor enclosure, which decreases cabling runs and simplifies field wiring connections directly to the monitoring system. This specific metric assembly features a 100 mm probe penetration length (Option 100), one M20 cable fitting with two plugs (Option 03), and 3\/4-14 NPT mounting threads (Option 02) to accommodate the integrated standoff adapter. In contrast to unapproved variants, this system is certified with multiple hazardous area approvals, enabling deployment in Class I, Division 1 and 2 or Zone 0, 1, and 2 environments.\u003c\/p\u003e\n\n\u003ch3\u003eFeatures\u003c\/h3\u003e\n\u003cul\u003e\n  \u003cli\u003eOption 28 integrates a built-in 3300 XL 8 mm proximity probe pre-configured with multiple international hazardous area certifications.\u003c\/li\u003e\n  \u003cli\u003eOption 10 specifies a 100 mm metric standoff adapter to space the housing away from the machine case.\u003c\/li\u003e\n  \u003cli\u003eOption 100 designates a 100 mm probe penetration sleeve length for casing access and depth positioning.\u003c\/li\u003e\n  \u003cli\u003eOption 03 includes an installation kit with one metric M20 conduit fitting and two blanking plugs.\u003c\/li\u003e\n  \u003cli\u003eOption 02 provides 3\/4-14 NPT mounting threads to support secure physical attachment of the standoff adapter.\u003c\/li\u003e\n  \u003cli\u003ePolyphenylene sulfide (PPS) thermoplastic housing with glass and conductive fibers offers Type 4X and IP66 environmental protection and static dissipation.\u003c\/li\u003e\n  \u003cli\u003eIntegrated Proximitor sensor design facilitates direct-to-monitor field wiring, eliminating intermediate extension cables.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eApplications\u003c\/h3\u003e\n\u003cp\u003eThis integrated transducer system is optimized for machinery protection environments where cabling space is limited or where traditional separate housings are difficult to install. Typical industrial applications include:\u003c\/p\u003e\n\u003cul\u003e\n  \u003cli\u003eShaft radial vibration and axial position measurement on high-speed rotating machinery.\u003c\/li\u003e\n  \u003cli\u003eTurbine, compressor, generator, and gearbox monitoring systems.\u003c\/li\u003e\n  \u003cli\u003eSevere environmental applications requiring robust non-corrosive chemical protection and static dissipation.\u003c\/li\u003e\n  \u003cli\u003eHazardous areas requiring intrinsically safe or non-incendive field installations.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eOrdering Information\u003c\/h3\u003e\n\u003ctable\u003e\n  \u003cthead\u003e\n    \u003ctr\u003e\n      \u003cth\u003eOption \/ Segment\u003c\/th\u003e\n      \u003cth\u003eCode on This SKU\u003c\/th\u003e\n      \u003cth\u003eMeaning from Datasheet\u003c\/th\u003e\n    \u003c\/tr\u003e\n  \u003c\/thead\u003e\n  \u003ctbody\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eOrderable Part Number\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e330881-28-10-100-03-02\u003c\/td\u003e\n      \u003ctd\u003ePROXPAC XL Proximity Transducer, Metric\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eA - Probe and Approvals Option\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e28\u003c\/td\u003e\n      \u003ctd\u003e3300 XL 8 mm probe with Multiple Approvals\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eB - Standoff Adapter Option (B Dimension)\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e10\u003c\/td\u003e\n      \u003ctd\u003e100 mm standoff adapter length\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eC - Probe Penetration Option (C Dimension)\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e100\u003c\/td\u003e\n      \u003ctd\u003e100 mm probe penetration length\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eD - Fittings Option (Supplied as a Kit)\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e03\u003c\/td\u003e\n      \u003ctd\u003eOne M20 fitting, two plugs\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eE - Mounting Thread Option\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e02\u003c\/td\u003e\n      \u003ctd\u003e3\/4-14 NPT (required when ordering Standoff Adapter Option)\u003c\/td\u003e\n    \u003c\/tr\u003e\n  \u003c\/tbody\u003e\n\u003c\/table\u003e\n\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003ctable\u003e\n  \u003ctbody\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eManufacturer\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003eBently Nevada (Baker Hughes)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003ePart Number\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e330881-28-10-100-03-02\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eTransducer System\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003ePROXPAC XL Proximity Transducer, Metric Assembly\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eInput Sensor\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e3300 XL 8 mm Proximity Probe with a 1-metre cable length installed in the probe sleeve\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003ePower Requirements\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003eRequires -17.5 Vdc to -26 Vdc at 12 mA maximum without barriers; -23 Vdc to -26 Vdc with barriers\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eLinear Range\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e2 mm (80 mils), starting at approximately 0.25 mm (10 mils) from target (from -1 Vdc to -17 Vdc output range)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eRecommended Gap Setting\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e1.27 mm (50 mils)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eIncremental Scale Factor (ISF)\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e7.87 V\/mm (200 mV\/mil) +\/- 5% including interchangeability error when measured in increments of 0.25 mm over the linear range\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eSupply Sensitivity\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003eLess than 2 mV change in output voltage per volt change in input voltage\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eOutput Resistance\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e50 Ohm\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eFrequency Response\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e0 to 10 kHz: +0, -3 dB with up to 305 metres of tinned field wiring\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eOperating Temperature (Probe)\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e-52 degC to +177 degC\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eOperating Temperature (Housing \u0026amp; Proximitor)\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e-52 degC to +100 degC\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eStorage Temperature\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e-52 degC to +105 degC\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eRelative Humidity\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e100% condensing, non-submersible when connectors are protected\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eHousing Material\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003eUltraviolet (UV) resistant, glass-reinforced polyphenylene sulfide (PPS) thermoplastic containing conductive fibers\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eProbe Tip Material\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003ePolyphenylene Sulfide (PPS)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eProbe Case Material\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003eAISI 304 stainless steel\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eSleeve \u0026amp; Retaining Chain Material\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003eAISI 304 stainless steel\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eOuter Sleeve \u0026amp; Retaining Screws Material\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003eAISI 303 stainless steel\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eSleeve O-Ring Material\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003eNeoprene\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eHousing IP Rating\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003eIP66 and Type 4X\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eRecommended Torque (Retaining Nut)\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e29.5 N-m (260 in-lb)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eRecommended Torque (Sleeve Locknut)\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e39.3 N-m (350 in-lb)\u003c\/td\u003e\n    \u003c\/tr\u003e\n  \u003c\/tbody\u003e\n\u003c\/table\u003e\n\n\u003ch3\u003eInstallation Guidelines\u003c\/h3\u003e\n\u003cp\u003eTo establish safe and accurate measurement parameters, adhere to the following setup practices:\u003c\/p\u003e\n\u003cul\u003e\n  \u003cli\u003eMount the housing assembly through the machine case using the 3\/4-14 NPT threads (Option 02) specified for standoff adapter configurations.\u003c\/li\u003e\n  \u003cli\u003eEnsure the internal 3300 XL 8 mm probe is set to the nominal gap of 1.27 mm (50 mils) from the target surface during installation.\u003c\/li\u003e\n  \u003cli\u003eUse 3-conductor shielded triaxial field wiring (0.2 to 1.5 mm2 or 16 to 24 AWG) with a tinned copper drain wire for signal connection back to the monitor.\u003c\/li\u003e\n  \u003cli\u003eProtect against water ingress by verifying that all conduit fittings (such as the M20 fitting supplied under Option 03) and blanking plugs are tight and properly sealed.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eCompliance and Certifications\u003c\/h3\u003e\n\u003cul\u003e\n  \u003cli\u003e\n\u003cstrong\u003eEMC:\u003c\/strong\u003e European Community Directive 2014\/30\/EU (EN 61000-6-2 for Industrial Immunity and EN 61000-6-4 for Industrial Emissions).\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eRoHS:\u003c\/strong\u003e European Community Directive 2011\/65\/EU.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eHazardous Area Approvals:\u003c\/strong\u003e Intrinsically Safe and Non-Incendive ratings for Class I, Zone 0, 1, and 2 (AEx\/Ex ia IIC T4\/T5 Ga; AEx\/Ex nA IIC T4\/T5 Gc; AEx\/Ex ec IIC T4\/T5 Gc) and Class I, Division 1 and 2, Groups A, B, C, D environments.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eMechanical Enclosure Rating:\u003c\/strong\u003e IP66 and Type 4X verified housing.\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Bently Nevada","offers":[{"title":"Default Title","offer_id":52666746929515,"sku":"330881-28-10-100-03-02","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/3227\/0443\/files\/bently-nevada-330881-28-10-100-03-02-proxpac-xl-proximity-transducer-dcleaqm2d4d_bdd9006f-a523-4d65-b538-51c5702bf492.jpg?v=1765446965","url":"https:\/\/www.plcprotech.com\/products\/bently-nevada-330881-28-10-100-03-02-proxpac-xl-proximity-transducer","provider":"PLC ProTech Ltd.","version":"1.0","type":"link"}