{"product_id":"bently-nevada-330901-00-96-10-02-05-3300-nsv-proximity-probe","title":"Bently Nevada 330901-00-96-10-02-05 3300 NSv Proximity Probe","description":"\u003ch3\u003eDescription\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003e330901-00-96-10-02-05\u003c\/strong\u003e specifies this 3300 NSv proximity probe configuration featuring a 1\/4-28 UNF thread without armor, a 0.0 in unthreaded length, a 9.6 in overall case length, a 1.0 m (39 in) total probe length, a miniature coaxial ClickLoc connector on a standard cable, and multiple agency approvals. This non-contact eddy-current displacement sensor is designed for tight clearances and restricted target areas where standard-diameter probes cannot fit, such as small-bore rotating machinery and aeroderivative gas turbines. It provides precise gap voltage output directly proportional to the physical distance between the probe tip and the target surface.\u003c\/p\u003e\n\u003cp\u003eUnlike armored sibling variants (such as the 330902 series) that use integrated stainless steel armor, the 330901 configuration uses an unarmored standard FEP-insulated coaxial cable for easier routing in narrow internal conduits. This specific variant has a 9.6 in (Option 96) case length and is completely threaded (Option 00 unthreaded length). It operates as part of a complete 3300 XL NSv proximity transducer system, interfacing with a 330930 extension cable and a 330980 Proximitor sensor to achieve a linear measurement range of 1.5 mm (60 mils).\u003c\/p\u003e\n\n\u003ch3\u003eFeatures\u003c\/h3\u003e\n\u003cul\u003e\n  \u003cli\u003eProbe Thread and Armor: 1\/4-28 UNF-2A thread configuration without stainless steel protective armor.\u003c\/li\u003e\n  \u003cli\u003eMechanical Dimensions: 0.0 in unthreaded length (fully threaded case) paired with a 9.6 in overall case length.\u003c\/li\u003e\n  \u003cli\u003eTotal Cable Length: 1.0 m (39 in) FEP-insulated standard coaxial probe lead.\u003c\/li\u003e\n  \u003cli\u003eClickLoc Connector: Gold-plated brass miniature coaxial ClickLoc connector to resist vibration-induced loosening.\u003c\/li\u003e\n  \u003cli\u003eHazardous Area Certification: Option 05 Multiple Approvals package (including ATEX, IECEx, and North American intrinsically safe certifications).\u003c\/li\u003e\n  \u003cli\u003eTip-to-Case Construction: TipLoc molding for a robust bond between the polyphenylene sulfide (PPS) probe tip and AISI 304 stainless steel case.\u003c\/li\u003e\n  \u003cli\u003eSecure Cable Attachment: CableLoc design providing up to 220 N (50 lb) of pull strength between the probe lead and the tip assembly.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eApplications\u003c\/h3\u003e\n\u003cul\u003e\n  \u003cli\u003eSmall-bore rotating machinery with tight clearances or limited target areas.\u003c\/li\u003e\n  \u003cli\u003eAeroderivative gas turbines and high-speed turbocompressors with restricted mounting geometry.\u003c\/li\u003e\n  \u003cli\u003eAxial shaft position and radial vibration measurements where cross-talk must be minimized in dense setups.\u003c\/li\u003e\n  \u003cli\u003eMachinery environments requiring high chemical resistance against process gases and synthetic lubricants.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eOrdering Information\u003c\/h3\u003e\n\u003ctable\u003e\n  \u003cthead\u003e\n    \u003ctr\u003e\n      \u003cth\u003eOption \/ Segment\u003c\/th\u003e\n      \u003cth\u003eCode on This SKU\u003c\/th\u003e\n      \u003cth\u003eDescription \/ Meaning from Datasheet\u003c\/th\u003e\n    \u003c\/tr\u003e\n  \u003c\/thead\u003e\n  \u003ctbody\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eOrderable Part Number\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e330901-00-96-10-02-05\u003c\/td\u003e\n      \u003ctd\u003e3300 NSv Proximity Probe, 1\/4-28 UNF thread, without armor\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eA - Unthreaded Length\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e00\u003c\/td\u003e\n      \u003ctd\u003e0.0 in unthreaded length (fully threaded)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eB - Overall Case Length\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e96\u003c\/td\u003e\n      \u003ctd\u003e9.6 in (96 tenths of an inch) overall case length\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eC - Total Length\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e10\u003c\/td\u003e\n      \u003ctd\u003e1.0 meter (39 in) probe total length\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eD - Connector \u0026amp; Cable Type\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e02\u003c\/td\u003e\n      \u003ctd\u003eMiniature coaxial ClickLoc connector, standard cable\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eE - Agency Approval\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e05\u003c\/td\u003e\n      \u003ctd\u003eMultiple Approvals (including CSA, ATEX, IECEx, and NEPSI\/CCC)\u003c\/td\u003e\n    \u003c\/tr\u003e\n  \u003c\/tbody\u003e\n\u003c\/table\u003e\n\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003ctable\u003e\n  \u003ctbody\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eManufacturer\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003eBently Nevada (Baker Hughes)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003ePart Number \/ Model\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e330901-00-96-10-02-05\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eProduct Family\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e3300 XL NSv Proximity Transducer System\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eThread Type\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e1\/4-28 UNF-2A (Standard Mount, without armor)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eUnthreaded Length\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e0.0 in\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eCase Length\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e9.6 in\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eProbe Length\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e1.0 m (39 in)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eConnector Type\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003eMiniature coaxial ClickLoc connector (Male)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eCable Type\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e75 ohm coaxial, fluoroethylene propylene (FEP) insulated standard cable\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eProbe Tip Material\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003ePolyphenylene sulfide (PPS)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eProbe Case Material\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003eAISI 304 stainless steel (SST)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eConnector Material\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003eGold-plated brass\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eAverage Scale Factor (ASF)\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e7.87 V\/mm (200 mV\/mil)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eLinear Range\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e1.5 mm (60 mils), from approximately 0.25 to 1.75 mm (10 to 70 mils) (-1 Vdc to -13 Vdc)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eRecommended Gap\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e1.0 mm (40 mils)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eIncremental Scale Factor (ISF) Error\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e+12.5% \/ -20% over 1.5 mm linear range\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eDeviation from Best Fit Straight Line (DSL)\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003eLess than +\/-0.06 mm (+\/-2.3 mils)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eFrequency Response\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e0 to 10 kHz (+0, -3 dB typical with up to 305 meters of field wiring)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eInput Power Requirement\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e-17.5 Vdc to -26 Vdc (12 mA maximum consumption)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eProbe Temperature Range\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e-52 degC to +177 degC (-62 degF to +351 degF) operating\/storage\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eProbe Pressure Seal\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003eViton O-ring (designed to seal differential pressure between tip and case)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eMinimum Bend Radius\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e25.4 mm (1.0 in)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eTensile Strength\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e220 N (50 lb) max probe case to lead pull strength\u003c\/td\u003e\n    \u003c\/tr\u003e\n  \u003c\/tbody\u003e\n\u003c\/table\u003e\n\n\u003ch3\u003eInstallation Guidelines\u003c\/h3\u003e\n\u003cul\u003e\n  \u003cli\u003e\n\u003cstrong\u003eGap Setting:\u003c\/strong\u003e Use a digital voltmeter to set the recommended 1.0 mm (40 mils) initial gap, corresponding to a nominal bias voltage output.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eThread Engagement:\u003c\/strong\u003e Do not exceed the maximum thread engagement length of 0.375 in for 1\/4-28 threads to prevent binding.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eTorquing:\u003c\/strong\u003e Tighten 1\/4-28 probe cases to a recommended torque of 5.1 N m (45 in lb) and a maximum rated torque of 7.3 N m (65 in lb).\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eBend Radius:\u003c\/strong\u003e Maintain a minimum bend radius of 25.4 mm (1.0 in) for both the probe cable and the extension cable during installation.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eCable Routing:\u003c\/strong\u003e Use conduit or cable trays to protect the unarmored coaxial lead. Secure connections using silicone self-fusing tape or connector protectors in oily environments.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003ePressure Seal:\u003c\/strong\u003e Note that while the probe features a Viton O-ring seal, exposing it to temperatures below -34 degC (-30 degF) for prolonged periods can affect the seal's flexibility.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eCompliance and Certifications\u003c\/h3\u003e\n\u003cul\u003e\n  \u003cli\u003e\n\u003cstrong\u003eElectrical Safety:\u003c\/strong\u003e SIL 2 (HFT=0), SIL 3 (HFT=1) certified for functional safety.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eHazardous Area Classifications:\u003c\/strong\u003e Ex ia IIC T5...T1 Ga, Ex ia IIIC T90degC...T280degC Dc (Intrinsically Safe EPL Ga\/Dc), Ex nA IIC T5...T1 Gc, Ex ec IIC T5...T1 Gc (Non-sparking\/Increased Safety EPL Gc) when connected per drawing 141092 or 140979.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eElectromagnetic Compatibility (EMC):\u003c\/strong\u003e European Union EMC Directive 2014\/30\/EU, EN 61000-6-2 (Immunity), EN 61000-6-4 (Emissions).\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eEnvironmental Compliance:\u003c\/strong\u003e RoHS Directive 2011\/65\/EU, China RoHS (EFUP 15 years).\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eMaritime Standards:\u003c\/strong\u003e Complies with ABS and other marine classification rules for offshore structures and marine vessels.\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Bently Nevada","offers":[{"title":"Default Title","offer_id":52666572833131,"sku":"330901-00-96-10-02-05","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/3227\/0443\/files\/bently-nevada-330901-00-96-10-02-05-3300-nsv-proximity-probes-qmnk0xjehez_0fad3eb1-9496-4f86-8ac9-66639ba2e467.jpg?v=1765440869","url":"https:\/\/www.plcprotech.com\/products\/bently-nevada-330901-00-96-10-02-05-3300-nsv-proximity-probe","provider":"PLC ProTech Ltd.","version":"1.0","type":"link"}