{"product_id":"bently-nevada-330902-00-15-10-02-05-3300-nsv-proximity-probe","title":"Bently Nevada 330902-00-15-10-02-05 3300 NSv Proximity Probe","description":"\u003ch3\u003eDescription\u003c\/h3\u003e\n\u003cp\u003eOption 00 (0.0 inches unthreaded length), Option 15 (1.5 inches overall case length), and Option 02 (miniature coaxial ClickLoc connector with standard cable) define the exact configuration of this \u003cstrong\u003e330902-00-15-10-02-05\u003c\/strong\u003e \u003cstrong\u003e3300 NSv Proximity Probe\u003c\/strong\u003e. This non-contact transducer is optimized for eddy-current displacement measurements in tight clearances or where target geometry is constrained, such as in small-bore rotating machinery or aeroderivative gas turbines. The built-in stainless steel armor provides robust mechanical protection against physical damage and abrasive environments, shielding the internal 75-ohm coaxial cable without sacrificing flexibility.\u003c\/p\u003e\n\u003cp\u003eUnlike standard unarmored configurations (such as model 330901) or options utilizing a connector protector (such as Option 01), this specific probe relies on standard stainless steel armor and a bare ClickLoc connector for direct-insertion setups. Additionally, the inclusion of Option 05 hazardous area certification extends its safe deployment into environments requiring multiple global agency approvals, including CSA, ATEX, and IECEx standards.\u003c\/p\u003e\n\n\u003ch3\u003eFeatures\u003c\/h3\u003e\n\u003cul\u003e\n  \u003cli\u003eOption 00 unthreaded design provides a fully threaded 1\/4-28 UNF case for precise gap calibration inside standard brackets.\u003c\/li\u003e\n  \u003cli\u003eOption 15 case length provides a 1.5 inch overall threaded envelope suitable for shallow mounting depths.\u003c\/li\u003e\n  \u003cli\u003eIntegrated stainless steel armor (model 330902) shields the coaxial cable from harsh physical hazards, pinching, and abrasion.\u003c\/li\u003e\n  \u003cli\u003eOption 10 length defines a 1.0 meter (39 inches) total probe length, minimizing intermediate cable connections inside the machine housing.\u003c\/li\u003e\n  \u003cli\u003eOption 02 miniature coaxial ClickLoc connector provides a secure, low-loss electrical connection to standard extension cables.\u003c\/li\u003e\n  \u003cli\u003eOption 05 agency approval package certifies the probe for intrinsic safety and non-incendive environments under multiple international bodies.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eApplications\u003c\/h3\u003e\n\u003cp\u003eThe 3300 NSv proximity system is designed for machinery with limited target size or tight physical clearances. Typical industrial applications include:\u003c\/p\u003e\n\u003cul\u003e\n  \u003cli\u003eRadial vibration and axial position measurements on small-diameter shafts under 30 mm (1.2 inches).\u003c\/li\u003e\n  \u003cli\u003eVibration monitoring on aeroderivative gas turbines with highly congested internal spacing.\u003c\/li\u003e\n  \u003cli\u003eThrust and radial displacement tracking in high-speed compressors and small-bore centrifugal pumps.\u003c\/li\u003e\n  \u003cli\u003eGeneral industrial rotating equipment requiring non-contact displacement monitoring in hazardous zones.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eOrdering Information\u003c\/h3\u003e\n\u003ctable\u003e\n  \u003cthead\u003e\n    \u003ctr\u003e\n      \u003cth\u003eOption\u003c\/th\u003e\n      \u003cth\u003eCode on This SKU\u003c\/th\u003e\n      \u003cth\u003eDescription\u003c\/th\u003e\n    \u003c\/tr\u003e\n  \u003c\/thead\u003e\n  \u003ctbody\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eOrderable Part Number\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e\u003cstrong\u003e330902-00-15-10-02-05\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e3300 NSv Proximity Probe, 1\/4-28 UNF-2A thread, with stainless steel armor\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eA: Unthreaded Length Option\u003c\/td\u003e\n      \u003ctd\u003e00\u003c\/td\u003e\n      \u003ctd\u003e0.0 in unthreaded length (fully threaded case)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eB: Overall Case Length Option\u003c\/td\u003e\n      \u003ctd\u003e15\u003c\/td\u003e\n      \u003ctd\u003e1.5 in (15 tenths of an inch) overall case length\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eC: Total Length Option\u003c\/td\u003e\n      \u003ctd\u003e10\u003c\/td\u003e\n      \u003ctd\u003e1.0 meter (39 in) system length\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eD: Connector and Cable-Type Option\u003c\/td\u003e\n      \u003ctd\u003e02\u003c\/td\u003e\n      \u003ctd\u003eMiniature coaxial ClickLoc connector, standard cable\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eE: Agency Approval Option\u003c\/td\u003e\n      \u003ctd\u003e05\u003c\/td\u003e\n      \u003ctd\u003eMultiple Approvals (CSA, ATEX, IECEx)\u003c\/td\u003e\n    \u003c\/tr\u003e\n  \u003c\/tbody\u003e\n\u003c\/table\u003e\n\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003ctable\u003e\n  \u003cthead\u003e\n    \u003ctr\u003e\n      \u003cth\u003eParameter\u003c\/th\u003e\n      \u003cth\u003eSpecification Value\u003c\/th\u003e\n    \u003c\/tr\u003e\n  \u003c\/thead\u003e\n  \u003ctbody\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eManufacturer\u003c\/td\u003e\n      \u003ctd\u003eBently Nevada\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003ePart Number\u003c\/td\u003e\n      \u003ctd\u003e330902-00-15-10-02-05\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eTransducer System\u003c\/td\u003e\n      \u003ctd\u003e3300 XL NSv Proximity Transducer System\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eThread Type\u003c\/td\u003e\n      \u003ctd\u003e1\/4-28 UNF-2A\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eArmor Material\u003c\/td\u003e\n      \u003ctd\u003eFlexible AISI 302 SST stainless steel\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eProbe Tip Material\u003c\/td\u003e\n      \u003ctd\u003ePolyphenylene sulfide (PPS)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eProbe Case Material\u003c\/td\u003e\n      \u003ctd\u003eAISI 304 stainless steel\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eCable Impedance\u003c\/td\u003e\n      \u003ctd\u003e75 ohms\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eCable Material\u003c\/td\u003e\n      \u003ctd\u003eFluoroethylene propylene (FEP) insulated probe cable\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eOperating Temperature Range\u003c\/td\u003e\n      \u003ctd\u003e-52 degC to +177 degC (-62 degF to +351 degF)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eLinear Range\u003c\/td\u003e\n      \u003ctd\u003e1.5 mm (60 mils), from approximately 0.25 to 1.75 mm (10 to 70 mils)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eAverage Scale Factor\u003c\/td\u003e\n      \u003ctd\u003e7.87 V\/mm (200 mV\/mil)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eIncremental Scale Factor (ISF)\u003c\/td\u003e\n      \u003ctd\u003e7.87 V\/mm (200 mV\/mil) +12.5% \/ -20% including interchangeability error\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eDeviation from Best Fit Straight Line (DSL)\u003c\/td\u003e\n      \u003ctd\u003eLess than +\/-0.06 mm (+\/-2.3 mils)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eRecommended Gap Setting\u003c\/td\u003e\n      \u003ctd\u003e1.0 mm (40 mils)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eRecommended Minimum Target Size\u003c\/td\u003e\n      \u003ctd\u003e13 mm (0.5 in) flat target diameter (9.5 mm \/ 0.375 in absolute minimum)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eMinimum Shaft Diameter\u003c\/td\u003e\n      \u003ctd\u003e30 mm (1.2 in) for standard mount configurations\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eTensile Strength (Maximum Rated)\u003c\/td\u003e\n      \u003ctd\u003e220 N (50 lb) probe case to lead\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eMaximum Case Torque\u003c\/td\u003e\n      \u003ctd\u003e7.3 N-m (65 in-lb)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eRelative Humidity Limits\u003c\/td\u003e\n      \u003ctd\u003e100% condensing, non-submersible when connectors are protected\u003c\/td\u003e\n    \u003c\/tr\u003e\n  \u003c\/tbody\u003e\n\u003c\/table\u003e\n\n\u003ch3\u003eInstallation Guidelines\u003c\/h3\u003e\n\u003cul\u003e\n  \u003cli\u003e\n\u003cstrong\u003eProbe Thread Engagement:\u003c\/strong\u003e Maximum recommended thread engagement length for 1\/4-28 UNF probe cases is 0.375 inches to avoid mechanical binding.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eCase Torque:\u003c\/strong\u003e Tighten the probe case to a recommended mounting torque of 5.1 N-m (45 in-lb), up to a maximum rating of 7.3 N-m (65 in-lb).\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eCable Bend Radius:\u003c\/strong\u003e Maintain a minimum physical bend radius of 25.4 mm (1.0 inch) for both armored and unarmored probe leads to prevent coaxial shielding degradation.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eConnector Protection:\u003c\/strong\u003e If the connection between the probe and extension cable is exposed to liquids or moisture, use silicone self-fusing tape or a connector protector kit to maintain signal integrity. Do not use silicone tape inside the machine casing.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eCompliance and Certifications\u003c\/h3\u003e\n\u003cul\u003e\n  \u003cli\u003e\n\u003cstrong\u003eOption 05 (Multiple Approvals):\u003c\/strong\u003e Certified for hazardous environments by CSA, ATEX, and IECEx.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eIntrinsic Safety:\u003c\/strong\u003e Ex ia IIC T5...T1 Ga; Ex ia IIIC T90degC...T280degC Dc (when installed per Bently Nevada drawing 141092).\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eNon-Incendive:\u003c\/strong\u003e Ex nA IIC T5...T1 Gc; Ex ec IIC T5...T1 Gc (when installed per Bently Nevada drawing 140979).\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eEuropean CE Mark:\u003c\/strong\u003e Fully compliant with electromagnetic compatibility (EMC) standards without requiring specialized shielded housings.\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Bently Nevada","offers":[{"title":"Default Title","offer_id":52666614153579,"sku":"330902-00-15-10-02-05","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/3227\/0443\/files\/bently-nevada-330902-00-15-10-02-05-proximity-probes-jx3c0whwv0y_c9f61ea1-a694-4931-9a48-3eabc376329b.jpg?v=1765444179","url":"https:\/\/www.plcprotech.com\/products\/bently-nevada-330902-00-15-10-02-05-3300-nsv-proximity-probe","provider":"PLC ProTech Ltd.","version":"1.0","type":"link"}