{"product_id":"bently-nevada-330903-04-10-10-01-00-3300-xl-nsv-proximity-probe","title":"Bently Nevada 330903-04-10-10-01-00 3300 XL NSv Proximity Probe","description":"\u003ch3\u003eDescription\u003c\/h3\u003e\n\u003cp\u003eThe \u003cstrong\u003e330903-04-10-10-01-00\u003c\/strong\u003e is an M8x1 thread 3300 XL NSv proximity probe, configured with a 0.4 in (approx. 10 mm) unthreaded length (Option 04), 1.0 m total length (Option 10), and a standard ClickLoc connector with connector protector (Option 01). This non-contact, eddy-current transducer is a core component of the \u003cstrong\u003e3300 XL NSv Proximity Transducer System\u003c\/strong\u003e, specifically engineered for applications with restrictive target area requirements or tight installation clearances where standard proximity systems are physically impractical.\u003c\/p\u003e\n\n\u003cp\u003eThis configuration is designed for high-frequency measurements on fluid-film bearing machinery, such as small-bore compressors, aeroderivative turbines, and high-speed equipment. The NSv system provides high sensitivity for radial vibration, axial position, and tachometer signals on shafts smaller than 51 mm (2.0 in) or flat targets smaller than 15 mm (0.6 in). The included connector protector (Option 01) ensures the electrical integrity of the miniature ClickLoc connection against environmental contaminants in industrial settings.\u003c\/p\u003e\n\n\u003ch3\u003eFeatures\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eOption 04\u003c\/strong\u003e: 0.4 in (approx. 10 mm) unthreaded probe body length\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eOption 10\u003c\/strong\u003e: 1.0 m total system length (probe + extension cable interface)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eOption 01\u003c\/strong\u003e: Miniature coaxial ClickLoc connector with integrated connector protector\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eOption 00\u003c\/strong\u003e: Agency approval not required\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eThread Type\u003c\/strong\u003e: M8x1 metric threading\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eNon-contact measurement\u003c\/strong\u003e: Eddy-current sensing for vibration and position\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eFluidLoc compatibility\u003c\/strong\u003e: Designed for reliable performance in oil-exposed environments\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eApplications\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eRadial vibration and radial position measurements on small-diameter shafts\u003c\/li\u003e\n\u003cli\u003eAxial (thrust) position measurements for small target geometries\u003c\/li\u003e\n\u003cli\u003eTachometer and zero speed measurements\u003c\/li\u003e\n\u003cli\u003ePhase reference (Keyphasor) signal acquisition\u003c\/li\u003e\n\u003cli\u003eCentrifugal air and refrigeration compressors\u003c\/li\u003e\n\u003cli\u003eProcess gas compressors and aeroderivative turbines\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eOrdering Information\u003c\/h3\u003e\n\u003ctable\u003e\n  \u003ctr\u003e\n    \u003cth\u003eOption\u003c\/th\u003e\n    \u003cth\u003eCode on This SKU\u003c\/th\u003e\n    \u003cth\u003eDescription\u003c\/th\u003e\n  \u003c\/tr\u003e\n  \u003ctr\u003e\n    \u003ctd\u003eOrderable Part Number\u003c\/td\u003e\n    \u003ctd\u003e330903-04-10-10-01-00\u003c\/td\u003e\n    \u003ctd\u003e3300 NSv Probe, M8x1 thread, without armor\u003c\/td\u003e\n  \u003c\/tr\u003e\n  \u003ctr\u003e\n    \u003ctd\u003eA - Unthreaded Length\u003c\/td\u003e\n    \u003ctd\u003e04\u003c\/td\u003e\n    \u003ctd\u003e0.4 in\u003c\/td\u003e\n  \u003c\/tr\u003e\n  \u003ctr\u003e\n    \u003ctd\u003eB - Case Length\u003c\/td\u003e\n    \u003ctd\u003e10\u003c\/td\u003e\n    \u003ctd\u003e1.0 in\u003c\/td\u003e\n  \u003c\/tr\u003e\n  \u003ctr\u003e\n    \u003ctd\u003eC - Total Length\u003c\/td\u003e\n    \u003ctd\u003e10\u003c\/td\u003e\n    \u003ctd\u003e1.0 meter\u003c\/td\u003e\n  \u003c\/tr\u003e\n  \u003ctr\u003e\n    \u003ctd\u003eD - Connector\/Cable\u003c\/td\u003e\n    \u003ctd\u003e01\u003c\/td\u003e\n    \u003ctd\u003eMiniature coaxial ClickLoc connector with connector protector\u003c\/td\u003e\n  \u003c\/tr\u003e\n  \u003ctr\u003e\n    \u003ctd\u003eE - Agency Approval\u003c\/td\u003e\n    \u003ctd\u003e00\u003c\/td\u003e\n    \u003ctd\u003eNot required\u003c\/td\u003e\n  \u003c\/tr\u003e\n\u003c\/table\u003e\n\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003ctable\u003e\n  \u003ctr\u003e\n    \u003cth\u003eParameter\u003c\/th\u003e\n    \u003cth\u003eSpecification\u003c\/th\u003e\n  \u003c\/tr\u003e\n  \u003ctr\u003e\n    \u003ctd\u003eManufacturer\u003c\/td\u003e\n    \u003ctd\u003eBently Nevada (Baker Hughes)\u003c\/td\u003e\n  \u003c\/tr\u003e\n  \u003ctr\u003e\n    \u003ctd\u003eModel\u003c\/td\u003e\n    \u003ctd\u003e330903\u003c\/td\u003e\n  \u003c\/tr\u003e\n  \u003ctr\u003e\n    \u003ctd\u003eProbe Thread\u003c\/td\u003e\n    \u003ctd\u003eM8x1\u003c\/td\u003e\n  \u003c\/tr\u003e\n  \u003ctr\u003e\n    \u003ctd\u003eArmor\u003c\/td\u003e\n    \u003ctd\u003eNone\u003c\/td\u003e\n  \u003c\/tr\u003e\n  \u003ctr\u003e\n    \u003ctd\u003eLinear Range\u003c\/td\u003e\n    \u003ctd\u003e1.5 mm (60 mils)\u003c\/td\u003e\n  \u003c\/tr\u003e\n  \u003ctr\u003e\n    \u003ctd\u003eRecommended Gap\u003c\/td\u003e\n    \u003ctd\u003e1.0 mm (40 mils)\u003c\/td\u003e\n  \u003c\/tr\u003e\n  \u003ctr\u003e\n    \u003ctd\u003eIncremental Scale Factor\u003c\/td\u003e\n    \u003ctd\u003e7.87 V\/mm (200 mV\/mil)\u003c\/td\u003e\n  \u003c\/tr\u003e\n  \u003ctr\u003e\n    \u003ctd\u003eOperating Temperature\u003c\/td\u003e\n    \u003ctd\u003e-52 degC to +177 degC\u003c\/td\u003e\n  \u003c\/tr\u003e\n  \u003ctr\u003e\n    \u003ctd\u003eConnector Type\u003c\/td\u003e\n    \u003ctd\u003eMiniature coaxial ClickLoc\u003c\/td\u003e\n  \u003c\/tr\u003e\n\u003c\/table\u003e\n\n\u003ch3\u003eInstallation Guidelines\u003c\/h3\u003e\n\u003cp\u003eEnsure the probe is installed with the specified gap of 1.0 mm (40 mils) from the target. Use Bently Nevada-supplied extension cables and Proximitor sensors to maintain system linearity. The connector protector provided with Option 01 must be correctly seated on the female connector to prevent fluid ingress. Verify that field wiring uses three-conductor shielded triad cable, with a maximum length of 305 meters (1,000 feet) between the Proximitor sensor and the monitoring system.\u003c\/p\u003e","brand":"Bently Nevada","offers":[{"title":"Default Title","offer_id":52666734674283,"sku":"330903-04-10-10-01-00","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/3227\/0443\/files\/bently-nevada-330903-04-10-10-01-00-3300-nsv-proximity-probes-eot4zn5sw2m_fc172014-8e04-4ca2-807e-163f21bab59e.jpg?v=1765446754","url":"https:\/\/www.plcprotech.com\/products\/bently-nevada-330903-04-10-10-01-00-3300-xl-nsv-proximity-probe","provider":"PLC ProTech Ltd.","version":"1.0","type":"link"}