{"product_id":"bently-nevada-330905-00-09-05-05-02-05-3300-xl-nsv-proximity-probe","title":"Bently Nevada 330905-00-09-05-05-02-05 3300 XL NSv Proximity Probe","description":"\u003ch3\u003eDescription\u003c\/h3\u003e\n\u003cp\u003eThe \u003cstrong\u003e330905-00-09-05-05-02-05\u003c\/strong\u003e is a \u003cstrong\u003e3300 XL NSv Proximity Probe\u003c\/strong\u003e specifically configured for precision vibration and axial position measurement in small-bore machinery. This non-contact, eddy-current transducer is designed for applications with limited target geometry or tight clearance requirements, such as aeroderivative turbines and high-speed equipment where standard probes may be too large or intrusive. The 330905 model features an M10x1 thread and is provided without stainless steel armor, facilitating installation in restricted spaces.\u003c\/p\u003e\n\n\u003cp\u003eThis transducer is a component of the 3300 XL NSv Proximity Transducer System, which includes the 330980 Proximitor Sensor and 330930 extension cable. The system maintains an accurate Average Scale Factor (ASF) even when monitoring shaft diameters smaller than 20 mm (0.8 in) or restricted counterbore areas. This specific configuration utilizes a 0.5 meter total system length and is fully compatible with Bently Nevada hazardous area installations, ensuring reliable, high-frequency response in demanding industrial environments.\u003c\/p\u003e\n\n\u003ch3\u003eFeatures\u003c\/h3\u003e\n\u003cul\u003e\n    \u003cli\u003eCompatible with 3300 XL NSv Proximity Transducer System for small-bore shaft vibration and axial position monitoring.\u003c\/li\u003e\n    \u003cli\u003eNon-contact eddy-current sensing technology eliminates mechanical wear and minimizes target area requirements.\u003c\/li\u003e\n    \u003cli\u003eM10x1 probe thread configuration without armor for compact installation.\u003c\/li\u003e\n    \u003cli\u003eDesigned for high-speed machinery, aeroderivative turbines, and tight clearance mounting scenarios.\u003c\/li\u003e\n    \u003cli\u003eClickLoc miniature coaxial connectors with connector protectors (depending on configuration) to ensure environmental sealing.\u003c\/li\u003e\n    \u003cli\u003eMeets rigorous hazardous area approval standards for Division 2 and Zone 2 installations.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eApplications\u003c\/h3\u003e\n\u003cul\u003e\n    \u003cli\u003eSmall-bore machinery and high-speed equipment protection.\u003c\/li\u003e\n    \u003cli\u003eAeroderivative gas turbines.\u003c\/li\u003e\n    \u003cli\u003eRadial vibration and axial position measurements in limited-clearance target areas.\u003c\/li\u003e\n    \u003cli\u003eCritical machinery monitoring where target geometry restricts use of standard 3300 XL 8 mm probes.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eOrdering Information\u003c\/h3\u003e\n\u003ctable\u003e\n    \u003ctr\u003e\n        \u003cth\u003eOption\u003c\/th\u003e\n        \u003cth\u003eCode\u003c\/th\u003e\n        \u003cth\u003eDescription\u003c\/th\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n        \u003ctd\u003eOrderable Part Number\u003c\/td\u003e\n        \u003ctd\u003e330905-00-09-05-05-02-05\u003c\/td\u003e\n        \u003ctd\u003e3300 XL NSv Proximity Probe, M10x1\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n        \u003ctd\u003eA - Unthreaded Length\u003c\/td\u003e\n        \u003ctd\u003e00\u003c\/td\u003e\n        \u003ctd\u003e0.0 mm (fully threaded)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n        \u003ctd\u003eB - Case Length\u003c\/td\u003e\n        \u003ctd\u003e09\u003c\/td\u003e\n        \u003ctd\u003e90 mm\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n        \u003ctd\u003eC - Total Length\u003c\/td\u003e\n        \u003ctd\u003e05\u003c\/td\u003e\n        \u003ctd\u003e0.5 meter\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n        \u003ctd\u003eD - Connector\/Cable Option\u003c\/td\u003e\n        \u003ctd\u003e05\u003c\/td\u003e\n        \u003ctd\u003eConfigured per orderable SKU\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n        \u003ctd\u003eE - Agency Approval\u003c\/td\u003e\n        \u003ctd\u003e02\u003c\/td\u003e\n        \u003ctd\u003eMultiple Approvals\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n        \u003ctd\u003eF - Suffix\u003c\/td\u003e\n        \u003ctd\u003e05\u003c\/td\u003e\n        \u003ctd\u003eAdditional Option Identifier\u003c\/td\u003e\n    \u003c\/tr\u003e\n\u003c\/table\u003e\n\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003ctable\u003e\n    \u003ctr\u003e\n        \u003cth\u003eParameter\u003c\/th\u003e\n        \u003cth\u003eSpecification\u003c\/th\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n        \u003ctd\u003eManufacturer\u003c\/td\u003e\n        \u003ctd\u003eBently Nevada (Baker Hughes)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n        \u003ctd\u003ePart Number\u003c\/td\u003e\n        \u003ctd\u003e330905-00-09-05-05-02-05\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n        \u003ctd\u003eProbe Diameter\u003c\/td\u003e\n        \u003ctd\u003eM10 x 1 Thread\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n        \u003ctd\u003eArmor\u003c\/td\u003e\n        \u003ctd\u003eNone\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n        \u003ctd\u003eProbe Tip Material\u003c\/td\u003e\n        \u003ctd\u003ePolyphenylene sulfide (PPS)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n        \u003ctd\u003eProbe Case Material\u003c\/td\u003e\n        \u003ctd\u003eAISI 304 Stainless Steel\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n        \u003ctd\u003eSystem Length\u003c\/td\u003e\n        \u003ctd\u003e0.5 meter\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n        \u003ctd\u003eConnector\u003c\/td\u003e\n        \u003ctd\u003eMiniature coaxial ClickLoc\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n        \u003ctd\u003eOperating Temperature\u003c\/td\u003e\n        \u003ctd\u003e-55 degC to +177 degC (Probe)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n        \u003ctd\u003eAgency Approvals\u003c\/td\u003e\n        \u003ctd\u003eATEX, IECEx, CSA (Multiple)\u003c\/td\u003e\n    \u003c\/tr\u003e\n\u003c\/table\u003e\n\n\u003ch3\u003eInstallation Guidelines\u003c\/h3\u003e\n\u003cp\u003eEnsure the transducer system is installed with the specified Proximitor Sensor (330980) and extension cable (330930). Proper installation includes isolating the Proximitor Sensor from the housing ground using a mounting pad to prevent ground loops. Cable routing should be performed to minimize interference with high-voltage lines. Connector protectors should be installed on all connections to ensure environmental sealing and prevent moisture ingress in industrial field conditions.\u003c\/p\u003e\n\n\u003ch3\u003eCompliance and Certifications\u003c\/h3\u003e\n\u003cul\u003e\n    \u003cli\u003eATEX\/IECEx: Ex ia IIC T5...T1 Ga; Ex nA IIC T5...T1 Gc\u003c\/li\u003e\n    \u003cli\u003eCSA (NRTL\/C): Class I, Div 2, Groups A, B, C, and D\u003c\/li\u003e\n    \u003cli\u003eFunctional Safety: SIL 2 (HFT=0); SIL 3 (HFT=1)\u003c\/li\u003e\n    \u003cli\u003eCompliance: RoHS Directive 2011\/65\/EU; EMC Directive 2014\/30\/EU\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Bently Nevada","offers":[{"title":"Default Title","offer_id":52666625327467,"sku":"330905-00-09-05-05-02-05","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/3227\/0443\/files\/bently-nevada-330905-00-09-05-05-02-05-3300-nsv-proximity-probes-2vvrbnx4pki_d85857bc-7b4b-4e0f-bb2b-dad31562b9cb.jpg?v=1765444326","url":"https:\/\/www.plcprotech.com\/products\/bently-nevada-330905-00-09-05-05-02-05-3300-xl-nsv-proximity-probe","provider":"PLC ProTech Ltd.","version":"1.0","type":"link"}