{"product_id":"bently-nevada-330905-00-12-05-02-00-3300-xl-nsv-proximity-probe","title":"Bently Nevada 330905-00-12-05-02-00 3300 XL NSv Proximity Probe","description":"\u003ch3\u003eDescription\u003c\/h3\u003e\n\u003cp\u003eThe \u003cstrong\u003e330905-00-12-05-02-00\u003c\/strong\u003e is a 3300 XL NSv proximity probe configured for applications requiring an M10x1 thread and non-armored construction. This transducer system is specifically engineered for machinery where space is limited or target surface area is restricted, such as aeroderivative turbines and small-bore rotating equipment. This configuration features a 0.5-meter cable length and a standard miniature coaxial ClickLoc connector, designed for seamless integration with the 3300 XL NSv Proximitor Sensor and extension cable.\u003c\/p\u003e\n\n\u003cp\u003eThe 3300 XL NSv proximity transducer system provides reliable non-contact displacement measurement for radial vibration and axial position monitoring. By optimizing the probe tip and coil design, the NSv system maintains a consistent scale factor even when monitoring targets smaller than the traditional 20 mm (0.8 in) diameter, making it the industry standard for high-speed, small-shaft machinery protection.\u003c\/p\u003e\n\n\u003ch3\u003eFeatures\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eM10x1 Thread\u003c\/strong\u003e: Precision-machined probe case suitable for standard mounting applications.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eNon-Armored Construction\u003c\/strong\u003e: Flexible, high-frequency coaxial cable without metallic armor for installations where abrasion protection is not required.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMiniature ClickLoc Connector\u003c\/strong\u003e: Reliable, locking connection that ensures signal integrity and simplifies installation.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e0.5 m Probe Length\u003c\/strong\u003e: Compact lead length for close-coupled proximity sensor mounting.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eNSv Technology\u003c\/strong\u003e: Engineered specifically for smaller target diameters, minimizing average scale factor (ASF) errors on tight-clearance shafts.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eStandardized 75 ohm Impedance\u003c\/strong\u003e: Compatible with all 3300 XL NSv system components.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eApplications\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eAeroderivative gas turbines\u003c\/li\u003e\n\u003cli\u003eSmall-bore compressors and pumps\u003c\/li\u003e\n\u003cli\u003eHigh-speed centrifugal equipment\u003c\/li\u003e\n\u003cli\u003eRadial vibration and axial position monitoring\u003c\/li\u003e\n\u003cli\u003eRotating machinery with limited target geometry or small shaft diameters\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eOrdering Information\u003c\/h3\u003e\n\u003ctable\u003e\n  \u003ctr\u003e\n    \u003cth\u003eOption\u003c\/th\u003e\n    \u003cth\u003eCode\u003c\/th\u003e\n    \u003cth\u003eDescription\u003c\/th\u003e\n  \u003c\/tr\u003e\n  \u003ctr\u003e\n    \u003ctd\u003eOrderable Part Number\u003c\/td\u003e\n    \u003ctd\u003e330905-00-12-05-02-00\u003c\/td\u003e\n    \u003ctd\u003e3300 XL NSv Proximity Probe, M10x1 thread, Non-Armored\u003c\/td\u003e\n  \u003c\/tr\u003e\n  \u003ctr\u003e\n    \u003ctd\u003eA - Unthreaded Length\u003c\/td\u003e\n    \u003ctd\u003e00\u003c\/td\u003e\n    \u003ctd\u003e0.0 in (0 mm)\u003c\/td\u003e\n  \u003c\/tr\u003e\n  \u003ctr\u003e\n    \u003ctd\u003eB - Case Length\u003c\/td\u003e\n    \u003ctd\u003e12\u003c\/td\u003e\n    \u003ctd\u003e1.2 in\u003c\/td\u003e\n  \u003c\/tr\u003e\n  \u003ctr\u003e\n    \u003ctd\u003eC - Total Length\u003c\/td\u003e\n    \u003ctd\u003e05\u003c\/td\u003e\n    \u003ctd\u003e0.5 meter (20 in)\u003c\/td\u003e\n  \u003c\/tr\u003e\n  \u003ctr\u003e\n    \u003ctd\u003eD - Connector\/Cable\u003c\/td\u003e\n    \u003ctd\u003e02\u003c\/td\u003e\n    \u003ctd\u003eMiniature coaxial ClickLoc connector, standard cable\u003c\/td\u003e\n  \u003c\/tr\u003e\n  \u003ctr\u003e\n    \u003ctd\u003eE - Agency Approval\u003c\/td\u003e\n    \u003ctd\u003e00\u003c\/td\u003e\n    \u003ctd\u003eNot required\u003c\/td\u003e\n  \u003c\/tr\u003e\n\u003c\/table\u003e\n\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003ctable\u003e\n  \u003ctr\u003e\n    \u003cth\u003eParameter\u003c\/th\u003e\n    \u003cth\u003eSpecification\u003c\/th\u003e\n  \u003c\/tr\u003e\n  \u003ctr\u003e\n    \u003ctd\u003eManufacturer\u003c\/td\u003e\n    \u003ctd\u003eBently Nevada\u003c\/td\u003e\n  \u003c\/tr\u003e\n  \u003ctr\u003e\n    \u003ctd\u003ePart Number\u003c\/td\u003e\n    \u003ctd\u003e330905-00-12-05-02-00\u003c\/td\u003e\n  \u003c\/tr\u003e\n  \u003ctr\u003e\n    \u003ctd\u003eProbe Thread\u003c\/td\u003e\n    \u003ctd\u003eM10 x 1\u003c\/td\u003e\n  \u003c\/tr\u003e\n  \u003ctr\u003e\n    \u003ctd\u003eProbe Type\u003c\/td\u003e\n    \u003ctd\u003eStandard Mount, Non-Armored\u003c\/td\u003e\n  \u003c\/tr\u003e\n  \u003ctr\u003e\n    \u003ctd\u003eCable Type\u003c\/td\u003e\n    \u003ctd\u003e75 Ohm coaxial, FEP insulated\u003c\/td\u003e\n  \u003c\/tr\u003e\n  \u003ctr\u003e\n    \u003ctd\u003eSystem Length\u003c\/td\u003e\n    \u003ctd\u003e0.5 m probe\u003c\/td\u003e\n  \u003c\/tr\u003e\n  \u003ctr\u003e\n    \u003ctd\u003eProbe Tip Material\u003c\/td\u003e\n    \u003ctd\u003ePolyphenylene sulfide (PPS)\u003c\/td\u003e\n  \u003c\/tr\u003e\n  \u003ctr\u003e\n    \u003ctd\u003eProbe Case Material\u003c\/td\u003e\n    \u003ctd\u003eAISI 304 stainless steel\u003c\/td\u003e\n  \u003c\/tr\u003e\n  \u003ctr\u003e\n    \u003ctd\u003eConnector\u003c\/td\u003e\n    \u003ctd\u003eMiniature coaxial ClickLoc\u003c\/td\u003e\n  \u003c\/tr\u003e\n\u003c\/table\u003e\n\n\u003ch3\u003eInstallation Guidelines\u003c\/h3\u003e\n\u003cp\u003eEnsure the probe is mounted securely using the provided M10x1 threads. When routing the cable, avoid sharp bends that may damage the FEP insulation. For systems requiring environmental protection, use a connector protector on the probe-to-extension cable junction. The proximity system should be checked for proper gap settings during installation to ensure it operates within the linear range of the transducer.\u003c\/p\u003e","brand":"Bently Nevada","offers":[{"title":"Default Title","offer_id":52666532888939,"sku":"330905-00-12-05-02-00","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/3227\/0443\/files\/bently-nevada-330905-00-12-05-02-00-3300-nsv-proximity-probes-2ockmmive40_da190deb-ec35-4868-afa4-eb7574962c84.jpg?v=1765440380","url":"https:\/\/www.plcprotech.com\/products\/bently-nevada-330905-00-12-05-02-00-3300-xl-nsv-proximity-probe","provider":"PLC ProTech Ltd.","version":"1.0","type":"link"}