{"product_id":"bently-nevada-330908-00-15-05-02-00-3300-nsv-proximity-probe","title":"Bently Nevada 330908-00-15-05-02-00 3300 NSv Proximity Probe","description":"\u003ch3\u003eDescription\u003c\/h3\u003e\n\u003cp\u003eAn unthreaded length of 0.0 inches (Option 00) and an overall case length of 1.5 inches (Option 15) define this \u003cstrong\u003e330908-00-15-05-02-00\u003c\/strong\u003e \u003cstrong\u003e3300 NSv proximity probe\u003c\/strong\u003e configuration, which is equipped with a 0.5-meter (20-inch) total length cable (Option 05).\u003c\/p\u003e\n\u003cp\u003eThis unarmored probe features standard 3\/8-24 UNF threads and a gold-plated miniature coaxial ClickLoc connector (Option 02) without an integrated connector protector. Supplying this probe configuration with the Option 00 approval selection means no agency certifications are required for the installation. The 3300 XL NSv proximity transducer system is specialized for machinery with highly restricted physical installations or exceptionally small target areas, such as centrifugal air compressors or refrigeration units. It is optimized to perform non-contact shaft displacement, radial vibration, and axial position monitoring on fluid-film bearing machines.\u003c\/p\u003e\n\n\u003ch3\u003eFeatures\u003c\/h3\u003e\n\u003cul\u003e\n  \u003cli\u003eOption 00 unthreaded design provides a fully threaded housing for fine-depth calibration.\u003c\/li\u003e\n  \u003cli\u003eOption 15 case length of 1.5 inches accommodates restricted envelopes in compressor enclosures.\u003c\/li\u003e\n  \u003cli\u003eOption 05 short-length cable of 0.5 meters (20 inches) reduces slack and simplifies internal cable routing.\u003c\/li\u003e\n  \u003cli\u003eOption 02 ClickLoc miniature coaxial connection delivers a secure and robust electrical interface.\u003c\/li\u003e\n  \u003cli\u003eUnarmored FEP-insulated coaxial cable design reduces weight and overall routing cross-section.\u003c\/li\u003e\n  \u003cli\u003ePolyphenylene sulfide (PPS) tip construction coupled with an AISI 304 stainless steel case offers high resistance to process fluids.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eApplications\u003c\/h3\u003e\n\u003cul\u003e\n  \u003cli\u003eRadial vibration and radial position measurements on compact compressors\u003c\/li\u003e\n  \u003cli\u003eAxial (thrust) position measurements on small-diameter machinery shafts\u003c\/li\u003e\n  \u003cli\u003eTachometer, speed, and phase reference (Keyphasor) signal generation\u003c\/li\u003e\n  \u003cli\u003eAeroderivative gas turbines and compact industrial machinery diagnostics\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eOrdering Information\u003c\/h3\u003e\n\u003ctable\u003e\n  \u003cthead\u003e\n    \u003ctr\u003e\n      \u003cth\u003eOption \/ Segment\u003c\/th\u003e\n      \u003cth\u003eCode on This SKU\u003c\/th\u003e\n      \u003cth\u003eDescription \/ Configuration Detail\u003c\/th\u003e\n    \u003c\/tr\u003e\n  \u003c\/thead\u003e\n  \u003ctbody\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eOrderable Part Number\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e330908-00-15-05-02-00\u003c\/td\u003e\n      \u003ctd\u003e3300 NSv Proximity Probe, 3\/8-24 UNF thread, without armor\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eA - Unthreaded Length Option\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e00\u003c\/td\u003e\n      \u003ctd\u003e0.0 inches (0.0 in) unthreaded length\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eB - Overall Case Length Option\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e15\u003c\/td\u003e\n      \u003ctd\u003e1.5 inches (1.5 in) overall case length\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eC - Total Length Option\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e05\u003c\/td\u003e\n      \u003ctd\u003e0.5 meters (20 inches) total length\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eD - Connector and Cable-Type Option\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e02\u003c\/td\u003e\n      \u003ctd\u003eMiniature coaxial ClickLoc connector, standard cable\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eE - Agency Approval Option\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e00\u003c\/td\u003e\n      \u003ctd\u003eNo hazardous area approvals required\u003c\/td\u003e\n    \u003c\/tr\u003e\n  \u003c\/tbody\u003e\n\u003c\/table\u003e\n\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003ctable\u003e\n  \u003cthead\u003e\n    \u003ctr\u003e\n      \u003cth\u003eParameter Group\u003c\/th\u003e\n      \u003cth\u003eSpecification Detail\u003c\/th\u003e\n    \u003c\/tr\u003e\n  \u003c\/thead\u003e\n  \u003ctbody\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eManufacturer\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003eBently Nevada (Baker Hughes)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003ePart Number \/ Model\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e330908-00-15-05-02-00\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eThread Specification\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e3\/8-24 UNF threads\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eMechanical Armor\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003eWithout stainless steel armor (unarmored)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eProbe Tip Material\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003ePolyphenylene sulfide (PPS)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eProbe Case Material\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003eAISI 304 stainless steel (SST)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eCable Construction\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e75 ohm coaxial, fluoroethylene propylene (FEP) insulated\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eConnector Type\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003eGold-plated brass ClickLoc miniature coaxial connector\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eSystem Linear Range\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e1.5 mm (60 mils), starting at approximately 0.25 mm (10 mils) from the target\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eTarget Calibration\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003eStandard calibration to AISI 4140 steel\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eRecommended Gap Setting\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e1.0 mm (40 mils)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eIncremental Scale Factor (ISF)\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e7.87 V\/mm (200 mV\/mil) nominal\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eDeviation from Best Fit Straight Line (DSL)\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003eLess than +\/-0.06 mm (+\/-2.3 mils)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eFrequency Response Range\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e0 to 10 kHz\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eProbe Sealing\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003eViton O-ring differential pressure seal between tip and case\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eOperating and Storage Temperature\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e-52 degC to +177 degC (-62 degF to +351 degF)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eRelative Humidity Limit\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e100% condensing, non-submersible with protected connectors\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eMaximum Case Torque\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e11.3 N m (100 in-lb) recommended; 33.9 N m (300 in-lb) maximum rated\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eCable Pull Strength (Tensile)\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e220 N (50 lb) maximum rated probe-case-to-lead and connector-to-connector pull\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eMinimum Cable Bend Radius\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e25.4 mm (1.0 in)\u003c\/td\u003e\n    \u003c\/tr\u003e\n  \u003c\/tbody\u003e\n\u003c\/table\u003e\n\n\u003ch3\u003eInstallation Guidelines\u003c\/h3\u003e\n\u003cp\u003eTo establish safe and precise vibration monitoring, the following engineering installation guidelines must be followed:\u003c\/p\u003e\n\u003cul\u003e\n  \u003cli\u003e\n\u003cstrong\u003eTorque Limits:\u003c\/strong\u003e For 3\/8-24 UNF steel probe cases, the recommended installation torque is 11.3 N m (100 in-lb). Do not exceed the maximum rated torque of 33.9 N m (300 in-lb) to avoid damage to the threads or internal seals.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eCable Protection:\u003c\/strong\u003e Keep the minimum cable bend radius above 25.4 mm (1.0 in). Avoid routing cables near high-voltage AC lines to prevent magnetic or electrostatic coupling.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eConnector Integrity:\u003c\/strong\u003e Coaxial ClickLoc connectors should be joined finger-tight. The use of connector protectors or silicone self-fusing tape is recommended in wet or oily environments to prevent signal degradation.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eTarget Geometry:\u003c\/strong\u003e Maintain proper clearances around the probe tip. To minimize side-view interference (cross-talk), ensure that the counterbore diameter surrounding the probe tip is at least 13 mm (0.5 in).\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eCompliance and Certifications\u003c\/h3\u003e\n\u003cp\u003eThe 3300 XL NSv Transducer System complies with the following standards and directives when integrated with compatible system components:\u003c\/p\u003e\n\u003cul\u003e\n  \u003cli\u003eEMC Directive 2014\/30\/EU (EN 61000-6-2, EN 61000-6-4)\u003c\/li\u003e\n  \u003cli\u003eRoHS Directive 2011\/65\/EU\u003c\/li\u003e\n  \u003cli\u003eFunctional Safety: SIL 2 (HFT=0), SIL 3 (HFT=1) certified\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Bently Nevada","offers":[{"title":"Default Title","offer_id":52666554220907,"sku":"330908-00-15-05-02-00","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/3227\/0443\/files\/bently-nevada-330908-00-15-05-02-00-proximity-probes-uaixbxpipya_9de3bdda-d0a4-410c-8de2-2cff316b1065.jpg?v=1765440609","url":"https:\/\/www.plcprotech.com\/products\/bently-nevada-330908-00-15-05-02-00-3300-nsv-proximity-probe","provider":"PLC ProTech Ltd.","version":"1.0","type":"link"}