{"product_id":"bently-nevada-330909-00-60-10-02-05-3300-nsv-proximity-probe","title":"Bently Nevada 330909-00-60-10-02-05 3300 NSv Proximity Probe","description":"\u003ch3\u003eDescription\u003c\/h3\u003e\n\u003cp\u003eOption 00 (0.0 in unthreaded length) and Option 60 (6.0 in overall case length) specify this stainless steel armored \u003cstrong\u003e3300 NSv proximity probe\u003c\/strong\u003e configuration — \u003cstrong\u003e330909-00-60-10-02-05\u003c\/strong\u003e.\u003c\/p\u003e\n\u003cp\u003eUnlike unarmored versions such as the 330908, the 330909 design integrates protective stainless steel armor over the 1.0-meter coaxial cable to prevent abrasion and mechanical wear in challenging machinery environments. This configuration features a miniature coaxial ClickLoc connector (Option 02) with no connector protector and standard cable, and carries a multiple approvals agency package (Option 05) for installation in hazardous environments. This non-contact eddy-current displacement sensor is designed for tight clearances and reduced target areas where standard-sized probes cannot fit.\u003c\/p\u003e\n\n\u003ch3\u003eFeatures\u003c\/h3\u003e\n\u003cul\u003e\n  \u003cli\u003eOption 00 unthreaded length provides a fully threaded probe casing for compact mounting.\u003c\/li\u003e\n  \u003cli\u003eOption 60 provides a 6.0-inch overall case length constructed of robust AISI 304 stainless steel.\u003c\/li\u003e\n  \u003cli\u003eOption 10 specifies a 1.0-meter total probe cable length.\u003c\/li\u003e\n  \u003cli\u003eOption 02 includes a miniature coaxial ClickLoc connector on standard 75-ohm FEP-insulated cable.\u003c\/li\u003e\n  \u003cli\u003eIntegrated flexible AISI 302 stainless steel armor provides physical shielding for the cable.\u003c\/li\u003e\n  \u003cli\u003eOption 05 agency approval package delivers ATEX, IECEx, and CSA certifications for hazardous zones.\u003c\/li\u003e\n  \u003cli\u003ePolyphenylene sulfide (PPS) probe tip ensures excellent chemical resistance and durability.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eApplications\u003c\/h3\u003e\n\u003cp\u003eUsed in small-bore machinery, aeroderivative gas turbines, centrifugal compressors, pumps, and high-speed equipment with limited target geometries. This system is ideal for monitoring radial vibration, axial position, and speed in confined industrial spaces.\u003c\/p\u003e\n\n\u003ch3\u003eOrdering Information\u003c\/h3\u003e\n\u003ctable border=\"1\"\u003e\n  \u003cthead\u003e\n    \u003ctr\u003e\n      \u003cth\u003eOption \/ Segment\u003c\/th\u003e\n      \u003cth\u003eCode on This SKU\u003c\/th\u003e\n      \u003cth\u003eDescription\u003c\/th\u003e\n    \u003c\/tr\u003e\n  \u003c\/thead\u003e\n  \u003ctbody\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eOrderable Part Number\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e330909-00-60-10-02-05\u003c\/td\u003e\n      \u003ctd\u003e3300 NSv Proximity Probe, 3\/8-24 UNF thread, with armor\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eA - Unthreaded Length Option\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e00\u003c\/td\u003e\n      \u003ctd\u003e0.0 in unthreaded length\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eB - Overall Case Length Option\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e60\u003c\/td\u003e\n      \u003ctd\u003e6.0 in overall case length\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eC - Total Length Option\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e10\u003c\/td\u003e\n      \u003ctd\u003e1.0 meter (39 in) total length\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eD - Connector and Cable-Type Option\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e02\u003c\/td\u003e\n      \u003ctd\u003eMiniature coaxial ClickLoc connector, standard cable\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eE - Agency Approval Option\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e05\u003c\/td\u003e\n      \u003ctd\u003eMultiple Approvals (CSA, ATEX, IECEx intrinsically safe \u0026amp; non-incendive)\u003c\/td\u003e\n    \u003c\/tr\u003e\n  \u003c\/tbody\u003e\n\u003c\/table\u003e\n\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003ctable border=\"1\"\u003e\n  \u003ctbody\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eManufacturer\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003eBently Nevada (Baker Hughes)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003ePart Number\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e330909-00-60-10-02-05\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eThread Size\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e3\/8-24 UNF-2A\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eCase Material\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003eAISI 304 stainless steel (SST)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eTip Material\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003ePolyphenylene sulfide (PPS)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eCable Armor\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003eFlexible AISI 302 SST uncoated armor\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eCable Type\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e75-ohm coaxial, FEP insulated probe cable\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eConnector Type\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003eGold-plated brass ClickLoc miniature male coaxial connector\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eSystem Compatibility\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e3300 XL NSv system (330980 Proximitor, 330930 extension cable)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eLinear Range\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e1.5 mm (60 mils), starting at approximately 0.25 mm (10 mils) from target\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eIncremental Scale Factor (ISF)\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e7.87 V\/mm (200 mV\/mil)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eRecommended Gap\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e1.0 mm (40 mils)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eDeviation from Best Fit Straight Line (DSL)\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003eLess than +\/-0.06 mm (+\/-2.3 mils)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eProbe DC Resistance (Center to Outer)\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e4.2 +\/- 0.5 ohms\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003ePower Input Requirements\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e-17.5 Vdc to -26 Vdc (at 12 mA maximum consumption without barriers)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eFrequency Response\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e0 to 10 kHz: +0, -3 dB\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eProbe Operating Temperature Range\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e-55 degC to +177 degC (-67 degF to +351 degF)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003eMaximum Rated Tensile Strength\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e220 N (50 lb) case-to-lead\u003c\/td\u003e\n    \u003c\/tr\u003e\n  \u003c\/tbody\u003e\n\u003c\/table\u003e\n\n\u003ch3\u003eInstallation Guidelines\u003c\/h3\u003e\n\u003cul\u003e\n  \u003cli\u003eMaintain a minimum 9.5 mm probe-to-probe clearance to prevent electromagnetic cross-talk.\u003c\/li\u003e\n  \u003cli\u003eEnsure the recommended minimum counterbore diameter of 13 mm (0.5 in) is applied.\u003c\/li\u003e\n  \u003cli\u003eTorque the 3\/8-24 thread casing up to a maximum rated torque of 33.9 N m (300 in-lb).\u003c\/li\u003e\n  \u003cli\u003eDo not exceed the minimum cable bend radius of 25.4 mm (1.0 in).\u003c\/li\u003e\n  \u003cli\u003eEnsure ClickLoc connectors are connected finger-tight during installation.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eCompliance and Certifications\u003c\/h3\u003e\n\u003cul\u003e\n  \u003cli\u003eClass I, Zone 0: AEx\/Ex ia IIC T5...T1 Ga\u003c\/li\u003e\n  \u003cli\u003eClass I, Division 2, Groups A, B, C, and D\u003c\/li\u003e\n  \u003cli\u003eATEX\/IECEx: Ex ia IIC T5...T1 Ga\u003c\/li\u003e\n  \u003cli\u003eATEX\/IECEx: Ex nA IIC T5...T1 Gc\u003c\/li\u003e\n  \u003cli\u003eATEX\/IECEx: Ex ec IIC T5...T1 Gc\u003c\/li\u003e\n  \u003cli\u003eFunctional Safety: SIL 2 (HFT = 0), SIL 3 (HFT = 1)\u003c\/li\u003e\n  \u003cli\u003eCE, RoHS Compliant\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Bently Nevada","offers":[{"title":"Default Title","offer_id":52666519716203,"sku":"330909-00-60-10-02-05","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/3227\/0443\/files\/bently-nevada-330909-00-60-10-02-05-i-o-interface-sn3dbjcxvc2_4eda0320-4834-44a4-b492-1f979f4db82f.jpg?v=1765440138","url":"https:\/\/www.plcprotech.com\/products\/bently-nevada-330909-00-60-10-02-05-3300-nsv-proximity-probe","provider":"PLC ProTech Ltd.","version":"1.0","type":"link"}