{"product_id":"bently-nevada-330930-045-01-05-3300-nsv-extension-cable","title":"Bently Nevada 330930-045-01-05 3300 NSv Extension Cable","description":"\u003ch3\u003eDescription\u003c\/h3\u003e\n\u003cp\u003eThe \u003cstrong\u003e330930-045-01-05\u003c\/strong\u003e is an industrial-grade \u003cstrong\u003e3300 XL NSv Extension Cable\u003c\/strong\u003e manufactured by \u003cstrong\u003eBently Nevada\u003c\/strong\u003e (a Baker Hughes business). This specialized coaxial cable provides critical low-loss signal transmission within the 3300 XL NSv Proximity Transducer System, acting as the bridge that links a 3300 NSv eddy-current proximity probe to a 3300 XL NSv Proximitor Sensor. The NSv (Narrow Side-view) system is specifically engineered for machinery with tight installation constraints—such as centrifugal air compressors, refrigeration compressors, and process gas machinery—where restricted side clearances, narrow counterbores, or small shaft diameters (smaller than 51 mm or 2 in) prevent the deployment of standard 5mm or 8mm proximity sensor configurations.\u003c\/p\u003e\n\u003cp\u003eAccording to the official Bently Nevada system specifications, the unarmored extension cable configuration maintains a strict technical \u003cstrong\u003elinear mass density of 45 grams per meter (0.5 oz\/ft)\u003c\/strong\u003e. For this specific variant featuring a \u003cstrong\u003e4.5-meter (14.8 feet) physical length\u003c\/strong\u003e, the net operational cable mass calculates to exactly \u003cstrong\u003e202.5 grams (7.14 oz)\u003c\/strong\u003e, excluding the terminal connectors. This precise weight distribution is critical for field engineers calculating cable tray load limits and strain-relief drop parameters in vertical conduit runs. Protected by a high-dielectric fluorinated ethylene propylene (FEP) outer jacket, this unarmored variant (\u003cstrong\u003e-01 option\u003c\/strong\u003e) offers maximum mechanical routing flexibility in complex conduit systems and is factory-certified with \u003cstrong\u003eMultiple Agency Approvals (-05 option)\u003c\/strong\u003e for seamless deployment in globally classified hazardous environments.\u003c\/p\u003e\n\u003ch3\u003eFeatures\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eComplete electrical and mechanical backward compatibility with legacy Bently Nevada 3300 RAM proximity transducer systems.\u003c\/li\u003e\n\u003cli\u003eHigh-precision unarmored design featuring a controlled linear mass density of 45 g\/m (0.5 oz\/ft) for accurate weight-load routing analysis.\u003c\/li\u003e\n\u003cli\u003ePremium fluorinated ethylene propylene (FEP) outer cable jacket providing high dielectric strength and chemical resistance against corrosive industrial lubes and solvents.\u003c\/li\u003e\n\u003cli\u003eFactory-terminated, gold-plated brass ClickLoc miniature coaxial connectors that lock securely to eliminate loose connections caused by severe machine vibration.\u003c\/li\u003e\n\u003cli\u003eSpecialized high-stability 75-ohm coaxial core preserving high-frequency RF signal fidelity and minimizing scale factor distortion over long terms.\u003c\/li\u003e\n\u003cli\u003eMultiple hazardous area agency certifications ensuring seamless, safe deployment across global refinery and chemical processing assets.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eApplications\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eRelaying critical dynamic radial vibration waveforms from narrow-clearance fluid-film bearings to centralized monitoring systems.\u003c\/li\u003e\n\u003cli\u003eInterconnecting axial thrust displacement probes located inside small-shaft industrial turbomachinery assemblies.\u003c\/li\u003e\n\u003cli\u003eTransmitting high-frequency tachometer, speed-sensing, and Keyphasor phase reference signals from restricted target areas.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eOption String Breakdown\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eOption Code Slot\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eSelected Option Value\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eTechnical Detail\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBase Model Designation\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e330930\u003c\/td\u003e\n\u003ctd\u003e3300 NSv Extension Cable Series\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eA: Cable Length Option\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e-045\u003c\/td\u003e\n\u003ctd\u003e4.5 meters (14.8 feet) total length\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eB: Connector \u0026amp; Cable Option\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e-01\u003c\/td\u003e\n\u003ctd\u003eStandard FEP jacket coaxial cable, without stainless steel armor\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eC: Agency Approval Option\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e-05\u003c\/td\u003e\n\u003ctd\u003eMultiple Approvals (North America, ATEX\/IECEx, etc. for hazardous locations)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eDetail\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eManufacturer\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eBently Nevada (Baker Hughes)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePart Variant ID\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e330930-045-01-05\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eTransducer System Sub-Series\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e3300 XL NSv Proximity Transducer System\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCable Core Impedance\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e75 ohms nominal\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePhysical Cable Length\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e4.5 meters (14.8 feet)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eLinear Mass Density (Cable)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e45 g\/m (0.5 oz\/ft) nominal\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eNet Calculated Cable Weight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e202.5 g (7.14 oz) calculated for 4.5m length (excluding connectors)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eArmor Protection Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eNone (Standard unarmored FEP outer jacket)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eConnector Interface Material\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eGold-plated brass ClickLoc male and female connections\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMaximum Connector Diameter\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e7.2 mm (0.285 in) absolute clearing profile\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMinimum Bend Radius\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e25.4 mm (1.0 in) minimum absolute field routing bend\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOperating Temperature Range\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e-52 degC to +100 degC (-62 degF to +212 degF)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eStorage Temperature Range\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e-52 degC to +105 degC (-62 degF to +221 degF)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRelative Environmental Humidity\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e100% condensing, non-submersible when connectors are insulated\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eConnections\/Interfaces\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eTermination Interface\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eFunction Assignment\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eClickLoc Miniature Coaxial Plug\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eConnects tightly with the integrated lead wire connector on the 3300 NSv proximity probe\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eClickLoc Miniature Coaxial Jack\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eStandard female coaxial port coupling into the 3300 XL NSv Proximitor Sensor input terminal\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eInstallation Guidelines\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eTotal Loop Matching Rule:\u003c\/strong\u003e Always pair this 4.5-meter extension cable with a compatible 0.5-meter proximity probe to achieve the exact \u003cstrong\u003e5.0-meter total loop system calibration length\u003c\/strong\u003e required by the 3300 XL NSv Proximitor Sensor. Mismatching system lengths (e.g., using a 4.5-meter cable in a 7.0-meter tuned proximitor loop) will severely corrupt the system's Average Scale Factor (ASF).\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eConduit Weight Strain Relief:\u003c\/strong\u003e For vertical conduit drops exceeding 3 meters, ensure the cable is supported properly. While the 4.5-meter cable weight is low (202.5 g), unsupported stretching under high thermal conditions can degrade the internal 75-ohm physical core geometry.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eConnector Weatherproofing:\u003c\/strong\u003e After locking the coaxial ClickLoc joints firmly together, slide dedicated connector protectors or apply a layer of self-fusing silicone tape over the junction points to seal against moisture ingress and prevent structural grounding shorts.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eAvoid Ground Contacts:\u003c\/strong\u003e The outer metal casing of the ClickLoc connectors must not make electrical contact with the machine casing or junction box walls. Grounding this connection introduces severe high-frequency noise loops into the low-voltage sensor circuit.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eConduit Protection Routing:\u003c\/strong\u003e Since this is an unarmored cable variant (-01), it should be routed through dedicated protective conduit or structural trunking channels to shield it from external physical cuts, pinching, and high-voltage electromagnetic interference (EMI).\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Bently Nevada","offers":[{"title":"Default Title","offer_id":52666616414571,"sku":"330930-045-01-05","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/3227\/0443\/files\/bently-nevada-330930-045-01-05-3300-nsv-extension-cable-u3qgtd3c3lm_9bacee9d-fee3-4de1-828a-8e08f357554d.jpg?v=1765444198","url":"https:\/\/www.plcprotech.com\/products\/bently-nevada-330930-045-01-05-3300-nsv-extension-cable","provider":"PLC ProTech Ltd.","version":"1.0","type":"link"}