{"product_id":"bently-nevada-3500-05-02-05-00-00-00-plc-chassis-system-rack","title":"Bently Nevada 3500\/05-02-05-00-00-00 System Rack","description":"\u003ch3\u003eDescription\u003c\/h3\u003e\n\u003cp\u003eThe \u003cstrong\u003eBently Nevada 3500\/05-02-05-00-00-00\u003c\/strong\u003e is a standardized hardware enclosure engineered to mount and interconnect all monitoring modules and power supplies within the \u003cstrong\u003e3500 Series Machinery Protection System\u003c\/strong\u003e. This specific configuration defines a 19-inch EIA full-size rack format designed for panel-mount installations, meaning it fits into rectangular panel cutouts and secures firmly from behind via specialized back-clamp sets. The backplane bus within the \u003cstrong\u003e3500\/05-02-05-00-00-00\u003c\/strong\u003e allows seamless digital communication and low-loss power distribution across its fourteen available general-purpose monitor slots. Positioned structurally with its power units and rack interface modules on the far left, the frame routes transducer input signals and I\/O signals directly through rear-facing interface boards, providing a foundational backbone for automated machinery protection and plant asset condition diagnostics across high-criticality industrial operations.\u003c\/p\u003e\n\u003ch3\u003eFeatures\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eComplete integrated enclosure assembly based on the \u003cstrong\u003e3500\/05-02-05-00-00-00\u003c\/strong\u003e hardware code, establishing a 14-slot panel-mount configuration.\u003c\/li\u003e\n\u003cli\u003e19-inch EIA standard architectural footprint with heavy-gauge chassis rails for reliable structural stability.\u003c\/li\u003e\n\u003cli\u003eIntegrated digital backplane enabling continuous communication and high-speed data transfer between monitoring nodes.\u003c\/li\u003e\n\u003cli\u003ePanel-mount format featuring specialized heavy-duty clamps accessible from the rear for tight panel integration.\u003c\/li\u003e\n\u003cli\u003eTailored far-left slot spacing specifically dimensioned to hold half-height power supply cards and primary rack interface cards.\u003c\/li\u003e\n\u003cli\u003eHigh system flexibility allowing any mix of vibration, position, speed, or temperature monitoring units within the 14 operational bays.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eApplications\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eStructural rack frameworks hosting vibration and machine protection arrays inside petrochemical facilities and chemical units.\u003c\/li\u003e\n\u003cli\u003eCentralized asset condition monitoring instrumentation panels on power plant steam and gas turbine decks.\u003c\/li\u003e\n\u003cli\u003eGrouping multi-channel turbomachinery monitoring modules across oil and gas offshore platforms and pipeline pumping stations.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eOrdering Information\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eOption Code\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eDescription\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e3500\/05-AA-BB-CC-DD-EE-FF\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eSystem Rack complete configuration matrix.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eA: 02\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eRack Size: 19-inch EIA Full-size Rack (14 available module slots), Panel Mount Format.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eB: 05\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eMounting Option: Panel Mount (mounts to cutouts in panels using clamps).\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eC: 00\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eAgency Approval Option: None.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eD: 00\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eReserved Option: None.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eE: 00\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eReserved Option: None.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eF: 00\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eReserved Option: None.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eParameter Category\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eSpecification Details\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eManufacturer\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eBently Nevada (Baker Hughes)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCombined Model\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003e3500\/05-02-05-00-00-00\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eChassis Format\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e19-inch EIA Full-Size Enclosure\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMounting Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003ePanel Mount (via rear heavy-duty clamps)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eAvailable Slots\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e14 general-purpose slots (plus far-left power and RIM bays)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eWiring Layout\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eField wiring and I\/O modules are fully accessible from the rear\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOverall Width (W)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e482.6 mm (19.00 in) —— Standard 19\" EIA rack width\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOverall Height (H)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e265.9 mm (10.47 in) —— Approximately 6U rack height\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOverall Depth (D)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e349.3 mm (13.75 in) —— Maximum depth from front panel to rear I\/O\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePanel Cutout Width\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e442.0 mm (17.40 in) —— Required rectangular opening width\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePanel Cutout Height\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e245.9 mm (9.68 in) —— Required rectangular opening height\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eEmpty Rack Weight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e7.10 kg (15.65 lb) typical\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOperating Temperature\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e-30 degC to +65 degC (-22 degF to +150 degF)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eStorage Temperature\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e-40 degC to +85 degC (-40 degF to +185 degF)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRelative Humidity\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e95%, non-condensing\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eChassis Material\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eIndustrial-grade sheet metal and high-strength structural aluminum\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eConnections\/Interfaces\u003c\/h3\u003e\n\u003cp\u003eThe panel-mount structural array routes vital wiring links and module pathways through specific zones:\u003c\/p\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eEnclosure Position \/ Component\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eFunctional Description \/ Assignment\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eFar-Left Slots\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eDedicated structural positions reserved strictly for the 3500\/15 power supplies and 3500\/20 rack interface module.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSlots 1 through 14\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eUniversal backplane receivers that house monitoring nodes, communication processors, or relay cards.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRear Enclosure Area\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eMain field wiring zone providing direct access to the backplane I\/O termination boards.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eChassis Ground Stud\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eDedicated grounding termination point ensuring low-impedance connection to the plant instrumentation earth.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eInstallation Guidelines\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eCutout Measurements:\u003c\/strong\u003e Ensure the rectangular opening in the instrument panel matches the precise official dimensional requirements for panel-mount 14-slot housings before hoisting the frame.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRear Access Check:\u003c\/strong\u003e Verify that there is adequate physical clearance behind the panel assembly to allow maintenance technicians to safely execute field wiring on the rear I\/O boards.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eClamp Securement:\u003c\/strong\u003e Tighten the heavy-duty fastening clamps supplied with the enclosure evenly against the panel surface to ensure a tight mechanical hold.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eComponent Tracking:\u003c\/strong\u003e Insert the core power supply units and the primary rack interface card into the far-left slots prior to populating any generic vibration or position monitoring cards.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eInstrumentation Grounding:\u003c\/strong\u003e Run a low-impedance copper grounding strap from the dedicated chassis ground stud directly to the verified plant instrumentation earth to mitigate electromagnetic noise.\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Bently Nevada","offers":[{"title":"Default Title","offer_id":52666854179179,"sku":"3500\/05-02-05-00-00-00","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/3227\/0443\/files\/bently-nevada-3500-05-02-05-00-00-00-plc-chassis-system-rack-pwy1xuco1yf_3ef4c67e-41cd-4acb-a766-95a62c2f73b8.jpg?v=1765449134","url":"https:\/\/www.plcprotech.com\/products\/bently-nevada-3500-05-02-05-00-00-00-plc-chassis-system-rack","provider":"PLC ProTech Ltd.","version":"1.0","type":"link"}