{"product_id":"bently-nevada-3500-15-01-00-01-low-voltage-ac-power-supply-module","title":"Bently Nevada 3500\/15-01-00-01 Low Voltage AC Power Supply Module","description":"\n\u003ch3\u003eDescription\u003c\/h3\u003e\n\u003cp\u003eThe \u003cstrong\u003e3500\/15-01-00-01\u003c\/strong\u003e is a half-height instrument rack component that converts wide-range input voltages into regulated voltages required by other functional modules within the 3500 Series Machinery Protection System. This specific \u003cstrong\u003epower supply module\u003c\/strong\u003e configuration features a low voltage AC module option designed for the top slot, paired with a blank or single-supply option for the bottom slot, and comes with North American hazardous area safety approvals.\u003c\/p\u003e\n\u003cp\u003eThe system accommodates up to two modules simultaneously to establish a redundant infrastructure. When two units are housed in a single chassis, the card seated in the lower slot manages primary operations, while the card resting in the upper position acts as the automatic backup resource. Under fully redundant arrangements, pulling or inserting an individual chassis supply does not interrupt machinery protection routines or disrupt ongoing rack operations.\u003c\/p\u003e\n\u003ch3\u003eFeatures\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eProvides full-chassis regulated power distribution from a single half-height slot footprint.\u003c\/li\u003e\n\u003cli\u003eSupports dual-supply hot-swappable installation to ensure uninterrupted condition monitoring backup.\u003c\/li\u003e\n\u003cli\u003eBuilt-in over-voltage protection that forces the fuse open on the input module during surge anomalies.\u003c\/li\u003e\n\u003cli\u003eIntegrated under-voltage safety limits to prevent internal circuit damage during brownout scenarios.\u003c\/li\u003e\n\u003cli\u003eClear front panel diagnostic tracking utilizing a dedicated status light indicator.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eApplications\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eHigh-availability industrial turbomachinery protection and diagnostic frameworks.\u003c\/li\u003e\n\u003cli\u003ePower generation gas and steam turbine monitoring lines requiring redundant instrumentation power.\u003c\/li\u003e\n\u003cli\u003eOil, gas, and chemical refining facilities operating under hazardous area zone guidelines.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eOrdering Information\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eSelection Code\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eDescription\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e3500\/15\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eAC and DC Power Supplies Series \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e-01\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003ePower Supply Type (Top Slot): Low Voltage ac (85 to 132 Vac rms) \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e-00\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003ePower Supply Type (Bottom Slot): No supply (or fuse when only one supply is required) \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e-01\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eAgency Approval Option: CSA\/NRTL\/C (Class 1, Div 2, Groups A, B, C, D) \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eManufacturer\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eBently Nevada (A subsidiary of General Electric Company) \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCountry of Origin\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eUSA \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eInput Voltage Range\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e85 to 132 Vac rms (120 to 188 Vac pk) \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eInput Frequency\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e47 to 63 Hz \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eFull Rack Current Draw\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e4.5 A rms maximum \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMinimum Loading Requirements\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eNo minimum rack load is required \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOperating Temperature\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e-30 degC to +65 degC (-22 degF to +150 degF) \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eStorage Temperature\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e-40 degC to +85 degC (-40 degF to +185 degF) \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRelative Humidity Limit\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e95%, non-condensing \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePower Supply Module Weight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1.39 kg (3.06 lb.) \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePower Input Module Weight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0.34 kg (0.75 lb.) \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePower Supply Dimensions (H x W x D)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e120.7 mm x 50.8 mm x 251.5 mm (4.75 in x 2.0 in x 9.9 in) \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePower Input Module Dimensions (H x W x D)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e120.7 mm x 25.4 mm x 114.3 mm (4.75 in x 1.0 in x 4.5 in) \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRack Space Requirement\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eTwo special half-height slots located on the left side of the rack \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eConnections\/Interfaces\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eComponent \/ Indicator\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eFunction \/ Routing\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSupply OK LED\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eFront panel indicator that illuminates when the power supply is operating properly.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePower Input Module (PIM)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eSpecial half-height module located directly behind the associated power supply for physical cable termination.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eInstallation Guidelines\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eSlot Configuration:\u003c\/strong\u003e Install the active module exclusively into the dedicated half-height slot allocations located on the far-left side of the 3500 system rack chassis.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRedundant Layout Balancing:\u003c\/strong\u003e When running a dual-supply setup, place the primary source inside the lower physical bay slot and slide the auxiliary backup hardware into the upper receiver position.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eElectrostatic Grounding:\u003c\/strong\u003e Technicians must hook up to a verified static-control wrist wrap mechanism before opening any protective casing or sliding cards into the backplane framework.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eThermal Aeration Monitoring:\u003c\/strong\u003e Maintain clean and open environmental ambient airflow properties around the left side of the chassis grid structure to confirm operating limits remain safely under +65 degC.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eCompliance and Certifications\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eEMC Standards:\u003c\/strong\u003e EN 61000-6-2 (Immunity for Industrial Environments), EN 55011\/CISPR 11, EN 61000-6-4 (Emissions).\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eEuropean Directives:\u003c\/strong\u003e EMC Directive 2004\/108\/EC, Low Voltage Directive 2006\/95\/EC.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eElectrical Safety:\u003c\/strong\u003e EN 61010-1 standard compliance.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eHazardous Area Approvals:\u003c\/strong\u003e CSA\/NRTL\/C Option 01: Class I, Division 2, Groups A, B, C, D; rated T4 @ Ta = -20 degC to +65 degC per reference installation drawing 149243.\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Bently Nevada","offers":[{"title":"Default Title","offer_id":52668307767659,"sku":"3500\/15-01-00-01","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/3227\/0443\/files\/3500-15-01-00-01-uqkbpptdlno_2bcaeafd-c665-4f43-9152-d3727ff339b9.jpg?v=1765520729","url":"https:\/\/www.plcprotech.com\/products\/bently-nevada-3500-15-01-00-01-low-voltage-ac-power-supply-module","provider":"PLC ProTech Ltd.","version":"1.0","type":"link"}