{"product_id":"bently-nevada-3500-15-05-05-00-universal-ac-power-supply-module","title":"Bently Nevada 3500\/15-05-05-00 Universal AC Power Supply Module","description":"\u003ch3\u003eProduct Overview\u003c\/h3\u003e\n\u003cp\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e3500\/15-05-05-00\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eis a high-availability, half-height power supply module designed to provide regulated DC power to the Bently Nevada 3500 Machinery Protection System. This\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e3500\/15-05-05-00\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003econfiguration is specifically engineered for dual-redundant power setups, utilizing two Universal AC inputs to ensure the monitoring system remains online even in the event of a single source power failure. In critical industrial sectors such as oil refining, offshore drilling, and thermal power generation, the 3500 system is the last line of defense for multi-million dollar rotating assets. This power supply module acts as the foundation of that defense; by offering superior surge protection and voltage regulation, it eliminates the risk of monitoring gaps caused by electrical transients, thereby preventing costly unplanned shutdowns and ensuring continuous mechanical health data flow.\u003c\/p\u003e\n\u003ch3\u003eSuffix Breakdown\u003c\/h3\u003e\n\u003cp\u003eThe model code\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e3500\/15-05-05-00\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003especifies a dual-AC input hardware profile for maximum system uptime:\u003c\/p\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003e3500\/15:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eBase series for the 3500 Machinery Protection System Power Supply.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003e05 (Lower Power Supply):\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eConfigured for Universal AC voltage, accepting 85 to 264 VAC rms.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003e05 (Upper Power Supply):\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eSecondary supply also configured for Universal AC voltage (85 to 264 VAC rms) for redundant operation.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003e00 (Agency Approval):\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eStandard version with no specific hazardous area certifications.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr class=\"firstRow\"\u003e\n\u003ctd\u003e\u003cstrong\u003eAttribute\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eSpecification Details\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eModel\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e3500\/15-05-05-00\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eBrand\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eBently Nevada (Baker Hughes)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eOrigin\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eU.S.A.\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eInput Voltage\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e85 to 264 VAC rms (Universal AC)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eInput Frequency\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e47 to 63 Hz\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eDimensions\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e25.15 cm x 5.08 cm x 12.07 cm\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eOperating Temp\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e-30 to +65 deg C\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eSystem Capacity\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003ePowers a full 3500 rack including all monitors\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eNet Weight\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e1.39 kg\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eSystem Integration FAQs\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eDoes this module support hot-swapping in a live rack?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eYes. The\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e3500\/15-05-05-00\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eis designed for high-availability environments. If you have a redundant power supply configuration, you can remove and replace one power supply module while the other continues to power the rack, ensuring no loss of protection during maintenance.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eCan I mix AC and DC power supplies in the same rack?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThe 3500 rack supports both AC and DC options, but the specific\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e-05-05\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003esuffix indicates that both slots are populated with Universal AC modules. If your facility requires an AC\/DC hybrid for different power grids, a different suffix configuration would be required.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eWhat is the significance of the \"Universal\" AC rating?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThe \"Universal\" rating means the module automatically adjusts to any input voltage between 85 and 264 VAC. This eliminates the need for manual jumpers or switches when deploying the system in different global regions with varying power standards.\u003c\/p\u003e\n\u003chr\u003e\n\u003ch3\u003eEngineering \u0026amp; Installation Guide\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eRedundancy and Power Sourcing\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eTo achieve true system redundancy with the\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e3500\/15-05-05-00\u003c\/strong\u003e, each power supply input should be connected to a physically separate power source (e.g., Source A from the main grid and Source B from an Uninterruptible Power Supply\/UPS). This prevents a single circuit breaker trip from taking down the entire machinery protection system.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eThermal Management in Enclosures\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThe 3500 power supply generates heat during the conversion process. When installing the rack in a sealed NEMA 4 or IP66 enclosure, calculate the total heat load to ensure the internal cabinet temperature does not exceed 65 deg C. Maintain at least 1 inch of clearance around the rack's cooling vents to allow for natural convection.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eInput Protection and Fuse Safety\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eAlways ensure that the external power lines are equipped with appropriate surge protection devices (SPDs). While the\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e3500\/15\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eincludes internal protection, external surges in heavy industrial environments can exceed these limits. Before removing a module, verify that the power switch on the front panel is in the \"Off\" position to prevent arcing at the backplane connectors.\u003c\/p\u003e\n\u003ch3\u003e\u003c\/h3\u003e","brand":"Bently Nevada","offers":[{"title":"Default Title","offer_id":52668319334763,"sku":"3500\/15-05-05-00","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/3227\/0443\/files\/350015-05-05-00-sukrnaw2i2w_0a650184-e394-4908-9e4e-34f2ccd47402.jpg?v=1765521139","url":"https:\/\/www.plcprotech.com\/products\/bently-nevada-3500-15-05-05-00-universal-ac-power-supply-module","provider":"PLC ProTech Ltd.","version":"1.0","type":"link"}