{"product_id":"bently-nevada-3500-15-07-00-00-low-voltage-dc-power-supply-module","title":"Bently Nevada 3500\/15-07-00-00 Low Voltage DC Power Supply Module","description":"\u003ch3\u003eDescription\u003c\/h3\u003e\n\u003cp\u003eThe \u003cstrong\u003e3500\/15-07-00-00\u003c\/strong\u003e operates as a half-height regulation instrument engineered to convert direct current input down to controlled voltage lines for downstream components within a \u003cstrong\u003e3500 Series Machinery Protection System\u003c\/strong\u003e. Positioned inside the designated left-hand slots of a standard rack enclosure, this specific low-voltage direct-current configuration ensures reliable machinery condition monitoring via an architecture supporting both single and dual-supply redundancies. The instrument prevents complete processing interruption during sudden primary branch drops and connects directly with a dedicated low-voltage direct-current Power Input Module (PIM) to interface field distribution lines within complex industrial automation plants.\u003c\/p\u003e\n\u003ch3\u003eFeatures\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eHalf-height physical profile supporting dual redundant power configurations inside a single monitoring chassis.\u003c\/li\u003e\n\u003cli\u003eComplete instrumentation bus power delivery capable of driving a fully occupied monitoring rack from a single module.\u003c\/li\u003e\n\u003cli\u003eHot-swappable installation design enabling modular module exchange without interrupting runtime protection services, provided a parallel redundant supply remains operational.\u003c\/li\u003e\n\u003cli\u003eFront-panel visual monitoring through a dedicated Supply OK status LED indicating stable regulation loops.\u003c\/li\u003e\n\u003cli\u003eIntegrated over-voltage and under-voltage protection networks designed to safeguard internal components during input supply transients.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eApplications\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eContinuous machinery protection networks in power generation, oil and gas, and petrochemical facilities.\u003c\/li\u003e\n\u003cli\u003eLow-voltage direct-current battery bank power distribution for turbomachinery monitoring.\u003c\/li\u003e\n\u003cli\u003eRedundant infrastructure configurations across hazardous processing areas.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eOrdering Information\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eOption Code\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eDescription\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e3500\/15\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eAC and DC Power Supplies\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eA: 07\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eLow Voltage DC Power Supply (20 to 30 Vdc)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eB: 00\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eNo supply (use when only one supply is required)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eC: 00\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eAgency Approval Option: None\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eCategory\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eData\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eElectrical\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eInput Voltage Range\u003c\/td\u003e\n\u003ctd\u003e20 to 30 Vdc\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003eInput Current Consumption\u003c\/td\u003e\n\u003ctd\u003e10.0 A dc maximum\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003eRedundant Balancing\u003c\/td\u003e\n\u003ctd\u003eLower rack slot designates primary source; upper slot handles backup handover\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eEnvironmental\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eOperating Temperature Range\u003c\/td\u003e\n\u003ctd\u003e-30 degC to +65 degC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003eStorage Temperature Range\u003c\/td\u003e\n\u003ctd\u003e-40 degC to +85 degC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003eRelative Humidity Range\u003c\/td\u003e\n\u003ctd\u003e95% non-condensing maximum\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMechanical\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003ePower Supply Module Dimensions (H x W x D)\u003c\/td\u003e\n\u003ctd\u003e120.7 mm x 50.8 mm x 251.5 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003ePower Supply Module Weight\u003c\/td\u003e\n\u003ctd\u003e1.39 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003ePower Input Module Dimensions (H x W x D)\u003c\/td\u003e\n\u003ctd\u003e120.7 mm x 25.4 mm x 114.3 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003ePower Input Module Weight\u003c\/td\u003e\n\u003ctd\u003e0.34 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003eDedicated Slot Allocation\u003c\/td\u003e\n\u003ctd\u003eRequires half-height position on the far-left rack section\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003eManufacturer\u003c\/td\u003e\n\u003ctd\u003eBently Nevada\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eInstallation Guidelines\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eRack Slot Assignment:\u003c\/strong\u003e Slide the main power module exclusively into the designated half-height front slots on the far-left section of the rack chassis.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRedundancy Phase Setup:\u003c\/strong\u003e For dual-redundant power setups, secure the primary low-voltage module in the bottom slot position and the secondary backup unit in the upper half-height location.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRear Module Alignment:\u003c\/strong\u003e Wire the incoming supply cables directly to the matching low-voltage direct-current Power Input Module positioned on the rear side of the rack, directly behind the front power card.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eCompliance and Certifications\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eEMC Directives:\u003c\/strong\u003e 2014\/30\/EU; EN 61000-6-2 (Immunity for Industrial Environments), EN 61000-6-4 (Emissions for Industrial Environments).\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eLow Voltage Safety:\u003c\/strong\u003e 2014\/35\/EU; EN 61010-1.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRoHS:\u003c\/strong\u003e 2011\/65\/EU.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMaritime Certification:\u003c\/strong\u003e DNV GL rules for classification of ships and offshore units; ABS rules for condition of classification.\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Bently Nevada","offers":[{"title":"Default Title","offer_id":52668315435371,"sku":"3500\/15-07-00-00","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/3227\/0443\/files\/350015-07-00-00-tnw5zjowage_4ad98092-fdf1-4e98-8d7a-dda7aeff80fa.jpg?v=1765520999","url":"https:\/\/www.plcprotech.com\/products\/bently-nevada-3500-15-07-00-00-low-voltage-dc-power-supply-module","provider":"PLC ProTech Ltd.","version":"1.0","type":"link"}