{"product_id":"bently-nevada-3500-22-01-01-01-288055-01-146031-01-transient-data-interface","title":"Bently Nevada 3500\/22-01-01-01 | 288055-01 +146031-01 | Transient Data Interface","description":"\u003ch3\u003eDescription\u003c\/h3\u003e\n\u003cp\u003eThe \u003cstrong\u003e3500\/22M\u003c\/strong\u003e Transient Data Interface (TDI), specifically ordered under configuration part number \u003cstrong\u003e3500\/22-01-01-01\u003c\/strong\u003e (comprising main module \u003cstrong\u003e288055-01\u003c\/strong\u003e and I\/O module \u003cstrong\u003e146031-01\u003c\/strong\u003e), provides a dedicated interface between the 3500 monitoring system and compatible configuration or condition monitoring software. This module combines the foundational rack interface functions of a standard 3500\/20 Rack Interface Module (RIM) with the high-capacity data collection capabilities of an advanced communication processor. It interfaces directly with M-series monitors within the rack to continuously collect steady-state and transient dynamic waveform data, transferring this information via an Ethernet link to host software platforms. While the \u003cstrong\u003e3500\/22M\u003c\/strong\u003e delivers vital system data processing, it operates outside of the critical monitoring path, ensuring that machinery protection functions remain fully available and completely unaffected by module operations.\u003c\/p\u003e\n\u003ch3\u003eFeatures\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eIntegrates the roles of a standard Rack Interface Module and a communication processor into a single slot.\u003c\/li\u003e\n\u003cli\u003eSupports continuous collection of both steady-state values and high-resolution transient dynamic waveforms.\u003c\/li\u003e\n\u003cli\u003eIncludes standard static data capture with optional dynamic channel enabling via a specialized validation disk.\u003c\/li\u003e\n\u003cli\u003eProvides dual communication paths via front-panel USB and rear-panel Ethernet configurations.\u003c\/li\u003e\n\u003cli\u003eOperates as a non-interfering component relative to the safety and automatic protection paths of the monitoring rack.\u003c\/li\u003e\n\u003cli\u003eFeatures four configurable nX static values per channel point, complete with amplitude and phase tracking.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eApplications\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eMachinery vibration monitoring and predictive maintenance analytics.\u003c\/li\u003e\n\u003cli\u003eTurbo-machinery startup and coastdown data logging.\u003c\/li\u003e\n\u003cli\u003eContinuous transient event and waveform capture in industrial power generation.\u003c\/li\u003e\n\u003cli\u003eConfiguration management and remote diagnostics for large-scale industrial motor and pump racks.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eOrdering Information\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eComponent \/ Suffix Code\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eDescription\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e3500\/22-01-01-01\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eComplete Module Assembly Order Number\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eA: 01\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eTransient Data Interface Type: Standard (use for standard monitoring applications)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eB: 01\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eI\/O Module Type: 10Base-T\/100Base-TX Ethernet I\/O Module\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eC: 01\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eAgency Approval: CSA\/NRTL\/C (Class 1, Division 2)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e288055-01\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eStandard Transient Data Interface Module with USB cable\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e146031-01\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e10Base-T\/100Base-TX I\/O Module\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e123M4610\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eFoot A to B USB cable (Included with 288055-01)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eParameter Category\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eSpecification Details\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eManufacturer\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eBently Nevada (Baker Hughes)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCountry of Origin\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eUSA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePower Consumption\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e10.5 Watts\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eEthernet Connection\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eRJ-45 for 10Base-T\/100Base-TX, autosensing, 100 meters maximum\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eUSB Interface\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eUSB-B front panel port, 115.2 kbaud maximum, 5 meters maximum cable length\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eStandard OK Relay\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eRated up to 5A @ 24 Vdc \/ 120 Vac, 120 Watts \/ 600 VA switched power max\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSupported Keyphasors\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e4 system Keyphasor signals up to 20 kHz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eKeyphasor Speed Ranges\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1 to 16 channels: 1 to 100,000 rpm; 17 to 24 channels: 1 to 60,000 rpm; 25 to 48 channels: 1 to 30,000 rpm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eWaveform Channels\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eSimultaneous collection for 48 channels, DC-coupled\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMain Module Weight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0.91 kg (2.0 lbs)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMain Module Dimensions\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e241.3 mm x 24.4 mm x 241.8 mm (9.50 in x 0.96 in x 9.52 in)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eI\/O Module Weight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0.20 kg (0.44 lbs)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eI\/O Module Dimensions\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e241.3 mm x 24.4 mm x 99.1 mm (9.50 in x 0.96 in x 3.90 in)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eTotal Weight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1.11 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRack Slot Occupancy\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1 full-height front slot (Main Module), 1 full-height rear slot (I\/O Module)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOperating Temperature\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e-30 degC to +65 degC (-22 degF to +149 degF)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eStorage Temperature\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e-40 degC to +85 degC (-40 degF to +185 degF)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRelative Humidity\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e95% non-condensing\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBattery Life (Powered)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e38 years @ 50 degC (122 degF)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBattery Life (Unpowered)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e12 years @ 50 degC (122 degF)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eConnections\/Interfaces\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eSystem Interface\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eFunction \/ Description\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eUSB-B Front Port\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eDirect computer connection utilizing BN Host Protocol for local configuration and data extraction.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRJ-45 Port (Copper I\/O)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eCore interface for network connections using Ethernet TCP\/IP supporting BN Host and TDI protocols.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e2-Pin Ground Connector\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eSpecific terminal block on the I\/O module for connecting Signal Common to Instrument Ground.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSystem Contacts Terminal\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003ePin headers dedicated to hardwired inputs for Trip Multiply, Alarm Inhibit, and Rack Reset.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eInstallation Guidelines\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eSlot Requirements:\u003c\/strong\u003e The main module must always be installed in Slot 1, directly adjacent to the rack power supply assemblies.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eUpgrade Precaution:\u003c\/strong\u003e When replacing an older 3500\/20 RIM, you must completely extract both the old RIM module and the old RIM I\/O card prior to inserting any new hardware. Failing to remove the legacy RIM I\/O card before installing the new module will cause severe hardware damage to the TDI.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eUpgrade Sequence:\u003c\/strong\u003e Follow this order exactly: 1) Remove the existing RIM, 2) Remove the existing RIM I\/O, 3) Install the new TDI I\/O card, 4) Install the new TDI main module.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eGrounding Configuration:\u003c\/strong\u003e When using the 2-pin Signal Common connector to bond to an Instrument Ground, slide the selector switch located on the Power Input Module (PIM) toward the \"HP\" mark to properly isolate Signal Common from chassis ground.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eUSB Connectivity:\u003c\/strong\u003e Always employ the dedicated USB cable (Part Number 123M4610) to preserve electrical isolation between the chassis and ground. Additionally, ensure that the connected computer is operating purely from its internal battery (completely disconnected from mains\/ground paths) to avoid generating hazardous ground loops.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eCompliance and Certifications\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eFCC:\u003c\/strong\u003e Complies with Part 15 of FCC Rules for interference.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eEMC Directives:\u003c\/strong\u003e European Community Directive 2014\/30\/EU; Standards EN 61000-6-2 (Immunity) and EN 61000-6-4 (Emissions).\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eElectrical Safety:\u003c\/strong\u003e European Community Directive 2014\/35\/EU; Standard EN 61010-1.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRoHS:\u003c\/strong\u003e European Community Directive 2011\/65\/EU.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMaritime Standards:\u003c\/strong\u003e DNV GL rules for classification (Ships, offshore units); ABS Rules for Condition of Classification Part 1, Steel Vessels Rules, Offshore Units and Structures.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eHazardous Area Approvals:\u003c\/strong\u003e Class I, Division 2, Groups A, B, C, and D (cNRTLus) certified under specific temperature range of -20 degC to +65 degC.\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Bently Nevada","offers":[{"title":"Default Title","offer_id":52668321661291,"sku":"288055-01 +146031-01","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/3227\/0443\/files\/350022-01-01-01288055-01-146031-01-nwwli4ezpyt_52447ece-9c82-498c-b49d-ca113d00625d.jpg?v=1765521166","url":"https:\/\/www.plcprotech.com\/products\/bently-nevada-3500-22-01-01-01-288055-01-146031-01-transient-data-interface","provider":"PLC ProTech Ltd.","version":"1.0","type":"link"}