{"product_id":"bently-nevada-3500-32-4-channel-relay-module","title":"Bently Nevada 3500\/32 4-Channel Relay Module","description":"\u003ch3\u003eDescription\u003c\/h3\u003e\n\u003cp\u003eThe \u003cstrong\u003e3500\/32\u003c\/strong\u003e is a full-height component designed for the \u003cstrong\u003eBently Nevada 3500\u003c\/strong\u003e series machinery protection system, providing four fully programmable relay outputs. This module can be placed in any of the slots to the right of the Rack Interface Module to drive critical alarm and machinery shutdown logic. Each relay utilizes highly configurable Alarm Drive Logic, which can be custom programmed using AND and OR combinations of alerts and dangers from any monitor channel within the rack. This decentralized logic configuration operates via the 3500 Rack Configuration Software to execute protective actions instantly, independent of host software control.\u003c\/p\u003e\n\u003cp\u003eThe hardware employs a highly resilient relay setup consisting of two single-pole, double-throw (SPDT) relays arranged in a double-pole, double-throw (DPDT) configuration for each of its four channels. Every channel features switch-selectable operations for Normally De-energized or Normally Energized modes, enabling flexible adaptation to fail-safe industrial layouts. Built-in onboard LED indicators allow field operators to perform dynamic, at-a-glance status tracking of communication buses and individual relay alarm conditions.\u003c\/p\u003e\n\u003ch3\u003eFeatures\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eFour independent relay outputs offering fully customizable, channel-specific voting logic paths.\u003c\/li\u003e\n\u003cli\u003eAlarm Drive Logic programming supporting extensive combinations of AND\/OR parameters across rack-wide inputs.\u003c\/li\u003e\n\u003cli\u003eDual SPDT relays connected in a robust DPDT physical layout for each independent channel.\u003c\/li\u003e\n\u003cli\u003eEpoxy-sealed relay constructions integrated with standard 250 Vrms arc suppressors for sustained contact safety.\u003c\/li\u003e\n\u003cli\u003eOnboard switch-selectable control allowing direct toggling between Normally Energized and Normally De-energized states.\u003c\/li\u003e\n\u003cli\u003eClear front-panel LED diagnostics indicating module OK, communication (TX\/RX), and individual channel alarm status.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eApplications\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eAutomatic emergency trip logging and machinery shutdown loops on critical industrial turbomachinery.\u003c\/li\u003e\n\u003cli\u003eInterlocking plant safety systems and visual\/audible alarm annunciator drive networks.\u003c\/li\u003e\n\u003cli\u003eDistributed voting logic configurations for balance-of-plant protection matrices across power generation and oil refineries.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eOrdering Information\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eDetail\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eProduct Ordering Reference\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMain Model Designation\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e3500\/32 (4-Channel Relay Module) \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOutput Module Option\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e-01 (4-Channel Relay I\/O Module) \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eAgency Approval Option\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e-00 (None) \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003e-01 (CSA \/ NRTL \/ C) \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eDetail\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eManufacturer\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eBently Nevada (Baker Hughes)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eModel Designation\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e3500\/32 \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eProduct Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e4-Channel Relay Module \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePower Consumption\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e6 watts typical \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRelay Type Configuration\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eTwo SPDT relays connected in a DPDT configuration per channel \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eEnvironmental Sealing\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eEpoxy-sealed \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eArc Suppressor Rating\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e250 Vrms (installed as standard) \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eContact Life Performance\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e100,000 cycles at 5 A, 24 Vdc or 120 Vac \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eMax Switched Voltage\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003edc: 30 Vdc \/ ac: 250 Vac \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMax Switched Current\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e5 A \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMinimum Switched Current\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e10 mA @ 5 Vdc \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eSwitched Power Capacity\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003edc: 120 W \/ ac: 600 VA \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMain Module Dimensions (H x W x D)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e241 mm x 24.4 mm x 242 mm \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMain Module Weight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0.7 kg \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eI\/O Module Dimensions (H x W x D)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e241 mm x 24.4 mm x 99.1 mm \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eI\/O Module Weight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0.4 kg \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOperating Temperature Bounds\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e-30 degC to +65 degC \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eStorage Temperature Bounds\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e-40 degC to +85 degC \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eHumidity Constraints\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e95%, non-condensing \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRack Space Requirement (Main)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1 full-height front slot \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRack Space Requirement (I\/O)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1 full-height rear slot \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eConnections\/Interfaces\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eTerminal Connection\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eFunction Assignment\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eNC\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eNormally Closed contact connection point per relay channel \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eARM\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eArmature \/ Common contact connection point per relay channel \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eNO\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eNormally Open contact connection point per relay channel \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRELAY MODE (NDE\/NE)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eHardware slide switches controlling individual channel energization states \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eInstallation Guidelines\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eModule Placement:\u003c\/strong\u003e Slide the main card directly into any available full-height front slot to the right of the Rack Interface Module. Insert the corresponding I\/O module into the matching rear chassis slot. Secure all faceplate screws.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRelay Mode Selection:\u003c\/strong\u003e Adjust the dedicated hardware switches on the I\/O panel prior to module power-up to establish Normally De-energized (NDE) or Normally Energized (NE) operation based on loop design.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWiring Configurations:\u003c\/strong\u003e Land all external device circuits onto the rear screw termination header block. Ensure proper landing for NC, ARM, and NO contact segments to prevent mechanical signaling errors.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eElectrostatic Grounding:\u003c\/strong\u003e Utilize a single-use grounding wrist strap when unboxing or modifying the internal circuitry parameters to safeguard the board elements from electrostatic shock.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eCompliance and Certifications\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eCE Mark Directives:\u003c\/strong\u003e Compliant with EMC Directive standards.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRadiated \u0026amp; Conducted Emissions:\u003c\/strong\u003e EN 55011, Class A.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eImmunity \u0026amp; Susceptibility Standard:\u003c\/strong\u003e IEC 61000-6-2, including ESD (61000-4-2), Radiated (ENV 50140), Conducted (ENV 50141), EFT (EN 61000-4-4), Surge (EN 61000-4-5), and Magnetic Field (61000-4-8).\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eHazardous Area Approvals:\u003c\/strong\u003e CSA\/NRTL\/C certified for Class I, Division 2, Groups A, B, C, D (T4 @Ta = -20 degC to +65 degC; Certification Number: CSA 150268-1002151).\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Bently Nevada","offers":[{"title":"Default Title","offer_id":52666544587115,"sku":"3500\/32","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/3227\/0443\/files\/bently-nevada-3500-32-4-channel-relay-module-bkzt4nr51v5_04f81160-46a1-4bce-8a94-c976310465bd.jpg?v=1765440504","url":"https:\/\/www.plcprotech.com\/products\/bently-nevada-3500-32-4-channel-relay-module","provider":"PLC ProTech Ltd.","version":"1.0","type":"link"}