{"product_id":"bently-nevada-3500-60-05-01-136711-01-rtd-tc-temperature-monitor","title":"Bently Nevada 3500\/60-05-01 136711-01 RTD\/TC Temperature Monitor","description":"\u003ch3\u003eProduct Overview\u003c\/h3\u003e\n\u003cp\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e3500\/60-05-01 (136711-01)\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eis a high-precision Temperature Monitor module designed for the Bently Nevada 3500 Machinery Protection System. This specific configuration features a non-isolated I\/O module with internal barriers and internal terminations, providing a compact and secure interface for critical machinery temperature points. Primarily utilized in power generation, hydrocarbon processing, and large-scale compression, the\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e3500\/60\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eaccepts inputs from up to six Resistance Temperature Detectors (RTDs) or Thermocouples (TCs). By integrating temperature monitoring directly into the machinery protection rack, it allows for seamless correlation between vibration and thermal data. This integration is vital for the early detection of bearing degradation or cooling system failures, significantly reducing the risk of catastrophic asset damage and unscheduled downtime in heavy industrial environments.\u003c\/p\u003e\n\u003ch3\u003eSuffix Breakdown\u003c\/h3\u003e\n\u003cp\u003eThe model nomenclature\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e3500\/60-05-01\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003edesignates a specific hardware build optimized for hazardous area safety and connectivity:\u003c\/p\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003e3500\/60:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eSeries designation for the RTD\/TC Temperature Monitor module.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eA: 05 (I\/O Module Type):\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eRTD\/TC Non-isolated I\/O Module equipped with Internal Barriers. This option is designed for applications where field sensors are located in hazardous areas, utilizing internal safety barriers to limit energy levels.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eB: 01 (Agency Approval):\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eCSA\/NRTL\/C (Class 1, Div 2) certified for North American safety standards in hazardous locations.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003e136711-01:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eThe specific rear I\/O component part number for internal termination and internal barrier functionality.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr class=\"firstRow\"\u003e\n\u003ctd\u003e\u003cstrong\u003eAttribute\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eModel\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e3500\/60-05-01\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eI\/O Part Number\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e136711-01\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eBrand\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eBently Nevada\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eInput Signals\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e1 to 6 RTD or TC channels\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eInput Impedance\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e10 MOhm per lead\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eRTD Support\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e100 Ohm Platinum (3\/4 wire), 120 Ohm Nickel, 10 Ohm Copper\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eTC Support\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eType E, J, K, T\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003ePower Consumption\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e7 Watts Nominal\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eAccuracy (Internal Term)\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e+\/- 3 deg C at 25 deg C\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eOperating Temp\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e0 deg C to +65 deg C\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eModule Weight\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e0.91 kg (Monitor), 0.46 kg (I\/O)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eDimensions (Monitor)\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e241.3 mm x 24.4 mm x 241.8 mm\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eField Inquiries and Support FAQ\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eCan I mix RTD and Thermocouple types on the same module?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThe 3500\/60 allows for individual channel configuration via software. However, the hardware I\/O type (Internal Barrier vs. Isolated) must be consistent for the module. Platinum 100 Ohm (0.00385 alpha) is recommended as the industrial standard for accuracy.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eWhat happens if a field wire shorts or breaks?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThe module features an OK LED and self-diagnostics. If a transducer signal goes out of range or a wire is severed, the OK LED will extinguish, and the Tx\/Rx LED will indicate status, preventing false trips while alerting operators.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eWhy is the full-scale range reduced for Type E Thermocouples above 35 deg C?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eIn isolated I\/O configurations at elevated ambient temperatures, thermal drift can affect the low-end linearity. For the non-isolated 05 option, accuracy remains consistent within the specified 0 to 65 deg C operating window.\u003c\/p\u003e\n\u003chr\u003e\n\u003ch3\u003eInstallation Guidelines and Engineering Advice\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eHazardous Area Integrity:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eWhen utilizing the 136711-01 I\/O with internal barriers, ensure that field wiring practices strictly adhere to the control drawings for Class 1, Div 2. The internal barriers are designed to limit energy, but improper grounding or bypassing of these terminals can compromise the safety rating of the entire rack.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eInternal Termination Routing:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eUse high-quality shielded twisted pair cabling for TC and RTD leads. Since this is an Internal Termination (IT) module, ensure that cable shields are grounded at the 3500 rack ground stud only. Avoid multi-point grounding to prevent ground loops that introduce noise into high-impedance temperature circuits.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eCold Junction Compensation (CJC):\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eFor Thermocouple applications, the CJC sensor is located on the I\/O module terminals. To ensure maximum accuracy, avoid installing heat-generating equipment (such as large power supplies) directly below the rear of the 3500 rack, as localized heating of the I\/O module can introduce measurement offsets.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eSlot Requirements:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eThe 3500\/60 monitor requires one full-height front slot, and the 136711-01 I\/O requires the corresponding full-height rear slot. Ensure the module is fully seated and the thumb screws are hand-tightened to maintain backplane communication integrity.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Bently Nevada","offers":[{"title":"Default Title","offer_id":52666850017643,"sku":"3500\/60-05-01  136711-01","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/3227\/0443\/files\/bently-nevada-3500-60-01-05-136711-01-rtd-tc-i-o-module-with-internal-barriers-and-internal-terminations-j5xg1sobbwu_320b72c3-d4ac-4bca-9af8-9b4035d1ad54.jpg?v=1765449017","url":"https:\/\/www.plcprotech.com\/products\/bently-nevada-3500-60-05-01-136711-01-rtd-tc-temperature-monitor","provider":"PLC ProTech Ltd.","version":"1.0","type":"link"}