{"product_id":"bently-nevada-3500-61-01-01-133835-02-temperature-monitor-isolated-i-o-module","title":"Bently Nevada 3500\/61-01-01 133835-02 Temperature Monitor Isolated I\/O Module","description":"\u003ch3\u003eProduct Overview\u003c\/h3\u003e\n\u003cp\u003eThe Bently Nevada\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e3500\/61-01-01\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e(\u003cstrong\u003e133835-02\u003c\/strong\u003e) is a high-performance Temperature Monitor Isolated Input\/Output (I\/O) Module featuring internal terminations. Designed for the\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e3500\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eMachinery Protection System, this module provides continuous tracking of machinery temperature variables to protect critical assets such as turbines, compressors, and large pumps from thermal damage.\u003c\/p\u003e\n\u003cp\u003eThis specific isolated configuration is engineered to eliminate ground loop interference, ensuring reliable data flow and preventing false trips in demanding environments like petrochemical refineries and power plants. The\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e133835-02\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eserves as the specific hardware component for isolated I\/O with internal termination resistors, facilitating direct thermocouple readings to the\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e3500\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003ebackplane.\u003c\/p\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr class=\"firstRow\"\u003e\n\u003ctd\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eSpecifications\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eModel\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003e3500\/61-01-01\u003c\/strong\u003e (\u003cstrong\u003e133835-02\u003c\/strong\u003e)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eBrand\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eBently Nevada (Baker Hughes)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eProduct Type\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eIsolated Thermocouple I\/O Module\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eInput Signal Types\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eIsolated Thermocouples (Type E, J, K, T)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eTermination Style\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eInternal Terminations\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003ePower Consumption\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e7.0 W maximum\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eIsolation Rating\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e500 VDC galvanic isolation\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eOperating Temp\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e-30 to 65 deg C\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eDimensions\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e241.3 mm x 24.4 mm x 103.1 mm\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eWeight\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e0.82 kg\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eOrigin\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eUSA\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eOrdering Information\u003c\/h3\u003e\n\u003cp\u003eAccurate identification of the model suffix is required to ensure compliance with hazardous area certifications and hardware compatibility.\u003c\/p\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eModel Number\u003c\/strong\u003e:\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e3500\/61-01-01\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003e3500\/61\u003c\/strong\u003e: Temperature Monitor Series Module.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003e01\u003c\/strong\u003e: Isolated Thermocouple I\/O Module with Internal Terminations.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003e01\u003c\/strong\u003e: Agency Approval (CN, ATEX, and IECEx for Zone 2 and Class I, Division 2).\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eHardware Part Number\u003c\/strong\u003e:\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e133835-02\u003c\/strong\u003e.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eEngineering \u0026amp; Installation Guide\u003c\/h3\u003e\n\u003ch3\u003eInstallation Steps\u003c\/h3\u003e\n\u003col class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eHardware Inspection\u003c\/strong\u003e: Examine module pins for damage and verify that jumper settings on the monitor card match the intended sensor type.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eI\/O Module Installation (Rear)\u003c\/strong\u003e: Align the\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e133835-02\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003ewith the rear chassis guides of the target slot. Seat the module firmly into the backplane and secure the thumb screws.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eMonitor Module Installation (Front)\u003c\/strong\u003e: Insert the\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e3500\/61\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eMonitor card into the front slot directly opposite the I\/O module. Secure with front panel screws.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eField Wiring\u003c\/strong\u003e: Connect sensor leads directly to the\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e133835-02\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eterminal blocks. For Thermocouples (TC), ensure correct polarity of positive and negative extension wires.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eConfiguration\u003c\/strong\u003e: Utilize the\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e3500\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eConfiguration Software via the TDI port to define sensor types and set Alert\/Danger setpoints before downloading to the rack.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ol\u003e\n\u003ch3\u003eTechnical Notes\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eInternal Terminations\u003c\/strong\u003e: This design allows field wiring to connect directly to the I\/O module, eliminating the need for external terminal blocks and reducing cabinet space requirements.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eSensor Failure Protection\u003c\/strong\u003e: The module features built-in detection for broken wires. A sensor fault triggers a \"Not OK\" status, alerting the DCS while preventing accidental machine trips.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eInput Constraints\u003c\/strong\u003e: This specific configuration (\u003cstrong\u003e-01\u003c\/strong\u003e) is dedicated to isolated thermocouple inputs. It cannot mix RTD and thermocouple signals on the same I\/O block.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eFAQ\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eWhat certifications does the -01 approval option provide?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eIt includes ATEX, IECEx, and CN certifications for use in Zone 2 and Class I, Division 2 hazardous environments.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eDoes this module require external resistors for termination?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eNo, the\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e133835-02\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003ehardware contains internal termination resistors.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eHow is isolation achieved?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThe module provides 500 VDC galvanic isolation to protect signal integrity from ground loop interference.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Bently Nevada","offers":[{"title":"Default Title","offer_id":52666865779051,"sku":"3500\/61-01-01 133835-02","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/3227\/0443\/files\/bently-nevada-3500-61-01-01-133835-02-rtd-tc-non-isolated-with-internal-terminations-otr0qowkozy_008e3679-5f87-4675-9c12-e49f7807f590.jpg?v=1765449441","url":"https:\/\/www.plcprotech.com\/products\/bently-nevada-3500-61-01-01-133835-02-temperature-monitor-isolated-i-o-module","provider":"PLC ProTech Ltd.","version":"1.0","type":"link"}