{"product_id":"bently-nevada-3500-91-01-cn-egd-communication-gateway-module","title":"Bently Nevada 3500\/91-01-CN EGD Communication Gateway Module","description":"\u003ch3\u003eDescription\u003c\/h3\u003e\n\u003cp\u003eThe \u003cstrong\u003e3500\/91-01-CN\u003c\/strong\u003e is an Ethernet Global Data (EGD) communication gateway module designed for the Bently Nevada 3500 machinery protection system. This module provides comprehensive communication capabilities for transmitting 3500 rack-monitored values, statuses, data values (float), and setpoints (float) over an Ethernet network path. It interfaces directly with EGD protocol compatible controllers to deliver response times suitable for demanding industrial controller applications. The module enables integration via Ethernet UDP\/IP frames , processing both producer exchanges and consumer exchanges such as group resets, group trip multiplies, group alarm inhibits, and group special alarm inhibits.\u003c\/p\u003e\n\u003ch3\u003eFeatures\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eProvides integration of 3500 rack values with EGD protocol compatible controllers.\u003c\/li\u003e\n\u003cli\u003eHigh-speed data transfer via Ethernet UDP\/IP protocol.\u003c\/li\u003e\n\u003cli\u003eSupports EGD version 2.01 protocol.\u003c\/li\u003e\n\u003cli\u003eFront panel LEDs indicate module operational health (OK LED) and rack communication status ($TX\/RX$ LED).\u003c\/li\u003e\n\u003cli\u003eAccommodates different physical layers including 10BASE-T\/100BASE-TX (twisted pair) and 100BASE-FX (fiber optic) via interchangeable I\/O modules.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eApplications\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eMachinery protection and condition monitoring systems.\u003c\/li\u003e\n\u003cli\u003eDistributed Control System (DCS) and Programmable Logic Controller (PLC) integration.\u003c\/li\u003e\n\u003cli\u003ePower generation facilities, petrochemical plants, and heavy industrial processing environments requiring real-time machinery asset data.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eOrdering Information\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eCode\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eDescription\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e3500\/91\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eEGD Communication Gateway \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e-AA\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eMain Module Type\u003c\/strong\u003e \u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e01\u003c\/td\u003e\n\u003ctd\u003eEGD Communication Gateway Module \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e-BB\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eI\/O Module Type\u003c\/strong\u003e \u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e01\u003c\/td\u003e\n\u003ctd\u003eEthernet 10BASE-T\/100BASE-TX I\/O Module \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e02\u003c\/td\u003e\n\u003ctd\u003eEthernet 100BASE-FX I\/O Module \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e-CC\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eAgency Approval Option\u003c\/strong\u003e \u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e00\u003c\/td\u003e\n\u003ctd\u003eNone \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e01\u003c\/td\u003e\n\u003ctd\u003eCSA\/NRTL\/C \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e02\u003c\/td\u003e\n\u003ctd\u003eCSA\/A \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eManufacturer\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eBently Nevada (Baker Hughes) \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eProduct Model\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e3500\/91-01-CN \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eProduct Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eEGD Communication Gateway Module \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCountry of Origin\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eUnited States of America\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePower Consumption\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e7.4 watts typical \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eData Types Supported\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eRack, Module, Channel, and Data value Status; Data values (float); Setpoints (float) \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eProducer Exchanges\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eStatus, Data values, Setpoints \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eConsumer Exchanges\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eGroup Reset, Group Trip Multiply, Group Alarm Inhibit, Group Special Alarm Inhibit \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eProtocols\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eEGD Version 2.01, Ethernet UDP\/IP frame, IEEE 802.3 CSMA\/CD \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCommunication Link\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eEthernet 10-Mbps and 100-Mbps (conforms to IEEE 802.3 and IEEE 802.3u) \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMain Module Dimensions\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e241.3 mm x 24.4 mm x 241.8 mm (9.50 in x 0.96 in x 9.52 in) \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMain Module Weight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0.79 kg (1.75 lbs.) \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eI\/O Module Dimensions\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e241.3 mm x 24.4 mm x 99.1 mm (9.50 in x 0.96 in x 3.90 in) \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eI\/O Module Weight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0.39 kg (0.85 lbs.) \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRack Space - Main Module\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1 full-height front slot \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRack Space - I\/O Module\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1 full-height rear slot \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOperating Temperature\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e-30 degC to +65 degC (-22 degF to +150 degF) \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eStorage Temperature\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e-40 degC to +85 degC (-40 degF to +185 degF) \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eHumidity\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e95%, noncondensing \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eConnections\/Interfaces\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eInterface\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eConnector \/ Jack Type\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eFunction\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eEthernet 10BASE-T\/100BASE-TX I\/O Module\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eRJ-45 jack \u003c\/td\u003e\n\u003ctd\u003eTwisted pair Ethernet network communication link \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eEthernet 100BASE-FX I\/O Module\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eMT-RJ jack \u003c\/td\u003e\n\u003ctd\u003eFiber optic Ethernet network communication link \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eInstallation Guidelines\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eRack Allocation:\u003c\/strong\u003e Install the main module into one full-height front slot of the 3500 rack. The associated I\/O module must be positioned directly behind it in the corresponding full-height rear slot.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSystem Requirements:\u003c\/strong\u003e This module requires Version 3.70 or higher of the 3500 Rack Configuration Software for setup.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eHardware Interfacing:\u003c\/strong\u003e The module must interface with a 3500\/22M Transient Data Interface (TDI) utilizing firmware version 1.20 or higher to successfully communicate with individual monitor modules.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSystem Constraints:\u003c\/strong\u003e Only one EGD module is permitted per 3500 rack.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eFirmware Requirements:\u003c\/strong\u003e For consumed exchange support, version 2.21 or higher of the 4-Channel firmware is mandatory.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eCompliance and Certifications\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eFCC:\u003c\/strong\u003e Complies with part 15 of the FCC Rules regarding harmful interference.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eEMC:\u003c\/strong\u003e European Community Directive 2014\/30\/EU; Standards EN 61000-6-2 (Immunity for Industrial Environments) and EN 61000-6-4 (Emissions for Industrial Environments).\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eElectrical Safety:\u003c\/strong\u003e European Community Directive 2014\/35\/EU (LV Directive) conforming to Standard EN 61010-1.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRoHS:\u003c\/strong\u003e European Community Directive 2011\/65\/EU.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMaritime:\u003c\/strong\u003e DNV GL rules for classification (Ships, offshore units, high speed\/light craft) and ABS Rules for Condition of Classification (Part 1, Steel Vessels Rules, Offshore Units and Structures).\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eHazardous Area Approvals:\u003c\/strong\u003e * CNRTLUS: Class I, Zone 2: AEx\/Ex nA nC ic IIC T4 Gc; Class I, Zone 2: AEx\/Ex ec nC ic IIC T4 Gc; Class I, Division 2, Groups A, B, C, and D; T4 @ Ta = -20 degC to +65 degC when installed per drawing 149243 or 149244.\n\u003cul\u003e\n\u003cli\u003eATEX\/IECEx: Ex II 3 G; Ex nA nc ic IIC T4 Gc; Ex ec nc ic IIC T4 Gc; T4 @ Ta = -20 degC to +65 degC when installed per drawing 149243 or 149244.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Bently Nevada","offers":[{"title":"Default Title","offer_id":52668316451179,"sku":"3500\/91-01-CN","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/3227\/0443\/files\/350091-01-cn-ygbjwokwszl_2878221e-1090-4efd-aecb-023db00e71df.jpg?v=1765521038","url":"https:\/\/www.plcprotech.com\/products\/bently-nevada-3500-91-01-cn-egd-communication-gateway-module","provider":"PLC ProTech Ltd.","version":"1.0","type":"link"}