{"product_id":"bently-nevada-3500-92-03-01-00-136188-01-ethernet-rs232-modbus-i-o-module","title":"Bently Nevada 3500\/92-03-01-00 136188-01 Ethernet\/RS232 Modbus I\/O Module","description":"\u003ch3\u003eDescription\u003c\/h3\u003e\n\u003cp\u003eThe \u003cstrong\u003eBently Nevada 3500\/92-03-01-00\u003c\/strong\u003e is a \u003cstrong\u003eCommunication Gateway Module\u003c\/strong\u003e designed for the \u003cstrong\u003e3500 Series Machinery Protection System\u003c\/strong\u003e. Its primary purpose is to provide continuous, high-speed communication capability for all rack-monitored values and statuses, enabling seamless integration with distributed control systems (DCS), programmable logic controllers (PLC), human-machine interfaces (HMI), and other plant automation systems.\u003c\/p\u003e\n\u003cp\u003eThe module features comprehensive communication interfaces, utilizing both Ethernet TCP\/IP and serial channels (RS232) via the \u003cstrong\u003e136188-01 I\/O module\u003c\/strong\u003e. It handles internal data collection by pulling current measured values, time stamps, module statuses, and alarm statuses from other monitor modules within the rack via a high-speed internal network. Additionally, the \u003cstrong\u003e3500\/92\u003c\/strong\u003e supports direct Ethernet communication with proprietary \u003cstrong\u003e3500 Rack Configuration Software\u003c\/strong\u003e and \u003cstrong\u003eData Acquisition Software\u003c\/strong\u003e. This specific variant features a Configurable Modbus Register Utility to map system data efficiently into host automation networks.\u003c\/p\u003e\n\u003ch3\u003eFeatures\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eContinuous collection of rack data, including current measured values with time stamps, module statuses, and alarm statuses.\u003c\/li\u003e\n\u003cli\u003eSimultaneous communication capability over Ethernet TCP\/IP and serial links.\u003c\/li\u003e\n\u003cli\u003eConfigurable Modbus Register Utility to customize register mapping for host systems.\u003c\/li\u003e\n\u003cli\u003eHigh-speed internal network collection rate that updates all rack modules in less than 1 second.\u003c\/li\u003e\n\u003cli\u003eFront panel LED indicators for immediate monitoring of module operational status (OK) and communication activity (TX\/RX).\u003c\/li\u003e\n\u003cli\u003eBackward compatibility with software features of the original 3500\/90 module.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eApplications\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eSteam and gas turbine vibration and status monitoring integration.\u003c\/li\u003e\n\u003cli\u003eCompressor and pump protection data transmission to plant DCS.\u003c\/li\u003e\n\u003cli\u003eIndustrial machinery condition monitoring and predictive maintenance networks.\u003c\/li\u003e\n\u003cli\u003ePower generation and petrochemical plant automation synchronization.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eOrdering Information\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e3500\/92: Communication Gateway\u003c\/li\u003e\n\u003cli\u003e03: Ethernet\/RS232 Modbus I\/O Module\u003c\/li\u003e\n\u003cli\u003e01: Low Memory\u003c\/li\u003e\n\u003cli\u003e00: None Agency Approval Option\u003c\/li\u003e\n\u003cli\u003e136188-01: Ethernet\/RS232 Modbus I\/O Module Spare (Includes Firmware Upgrade Kit 126M4118-01)\u003c\/li\u003e\n\u003cli\u003e126M4118-01: Firmware Upgrade Kit\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd data-row=\"1\"\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd data-row=\"1\"\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd data-row=\"2\"\u003e\u003cstrong\u003eManufacturer\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd data-row=\"2\"\u003eBently Nevada\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd data-row=\"3\"\u003e\u003cstrong\u003eCountry of Origin\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd data-row=\"3\"\u003eUSA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd data-row=\"4\"\u003e\u003cstrong\u003ePower Consumption\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd data-row=\"4\"\u003e5.0 Watts typical with Modbus RS232\/RS422 I\/O Module\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd data-row=\"5\"\u003e\u003cstrong\u003eData Types\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd data-row=\"5\"\u003eCurrent measured values with time stamp, module statuses, current alarm statuses\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd data-row=\"6\"\u003e\u003cstrong\u003eUpdate Time\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd data-row=\"6\"\u003eLess than 1 second for all modules in the 3500 rack\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd data-row=\"7\"\u003e\u003cstrong\u003eOK LED Output\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd data-row=\"7\"\u003eIndicates when the 3500\/92 is operating properly\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd data-row=\"8\"\u003e\u003cstrong\u003eTX\/RX LED Output\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd data-row=\"8\"\u003eIndicates when the 3500\/92 is communicating with other modules in the 3500 rack\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd data-row=\"9\"\u003e\u003cstrong\u003eBNC Host Protocol\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd data-row=\"9\"\u003eEthernet TCP\/IP connection to 3500 Configuration and Data Acquisition Software\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd data-row=\"10\"\u003e\u003cstrong\u003eModbus Protocol\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd data-row=\"10\"\u003eBased on AEG Modicon PI-MBUS-300 Reference Manual, Remote Terminal Unit (RTU) transmission mode\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd data-row=\"11\"\u003e\u003cstrong\u003eEthernet Link Speed\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd data-row=\"11\"\u003e10 Mbps, conforms to IEEE 802.3\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd data-row=\"12\"\u003e\u003cstrong\u003eEthernet Protocol\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd data-row=\"12\"\u003eEthernet TCP\/IP frame and Modbus\/TCP\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd data-row=\"13\"\u003e\u003cstrong\u003eEthernet Connection\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd data-row=\"13\"\u003eRJ-45 for 10BASE-T Ethernet cabling\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd data-row=\"14\"\u003e\u003cstrong\u003eOperating Temperature\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd data-row=\"14\"\u003e-30 degC to +65 degC (-22 degF to +149 degF)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd data-row=\"15\"\u003e\u003cstrong\u003eStorage Temperature\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd data-row=\"15\"\u003e-40 degC to +85 degC (-40 degF to +185 degF)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd data-row=\"16\"\u003e\u003cstrong\u003eHumidity\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd data-row=\"16\"\u003e95% non-condensing\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd data-row=\"17\"\u003e\u003cstrong\u003eMain Board Dimensions (H x W x D)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd data-row=\"17\"\u003e241 mm x 24.4 mm x 242 mm (9.50 in x 0.96 in x 9.52 in)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd data-row=\"18\"\u003e\u003cstrong\u003eI\/O Module Dimensions (H x W x D)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd data-row=\"18\"\u003e241 mm x 24.4 mm x 99.1 mm (9.50 in x 0.96 in x 3.90 in)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd data-row=\"19\"\u003e\u003cstrong\u003eMain Board Weight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd data-row=\"19\"\u003e0.82 kg (1.8 lb.)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd data-row=\"20\"\u003e\u003cstrong\u003eI\/O Module Weight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd data-row=\"20\"\u003e0.44 kg (0.96 lb.)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd data-row=\"21\"\u003e\u003cstrong\u003eTotal Assembly Weight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd data-row=\"21\"\u003e1.26 kg (2.76 lb.)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eConnections\/Interfaces\u003c\/h3\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd data-row=\"1\"\u003e\u003cstrong\u003eConnector Pin\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd data-row=\"1\"\u003e\u003cstrong\u003eFunction\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd data-row=\"2\"\u003eRJ-45 Jack\u003c\/td\u003e\n\u003ctd data-row=\"2\"\u003e10BASE-T Ethernet TCP\/IP and Modbus\/TCP Interface\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd data-row=\"3\"\u003eSerial Port (RS232)\u003c\/td\u003e\n\u003ctd data-row=\"3\"\u003eModicon Modbus RTU Serial Communication Interface\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eInstallation Guidelines\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eFirmware Verification:\u003c\/strong\u003e Ensure that older Communication Gateway main modules are upgraded using Firmware Upgrade Kit 126M4118-01 before installing the new 136188-01 I\/O module.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRack Insertion:\u003c\/strong\u003e Insert the main board into the designated communication slot of the 3500 rack, ensuring full seating and secure fastening of the chassis screws.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eI\/O Module Alignment:\u003c\/strong\u003e Install the 136188-01 I\/O module directly behind the main module from the rear of the 3500 rack.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCabling Constraints:\u003c\/strong\u003e Use standard 10BASE-T Ethernet cabling with RJ-45 connectors for network setups, limiting cable runs according to IEEE 802.3 metrics.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eEnvironmental Control:\u003c\/strong\u003e Ensure operating ambient conditions do not exceed 65 degC and that ventilation paths on the 3500 chassis remain unobstructed.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eCompliance and Certifications\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003ecNRTLus\u003c\/li\u003e\n\u003cli\u003eATEX\u003c\/li\u003e\n\u003cli\u003eIECEx\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eFAQ\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eWhat is the function of the 3500\/92 module?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eIt acts as a communication gateway, exporting data from a 3500 machinery protection rack to external automation systems like PLCs and DCS.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eWhich interfaces are provided on the 136188-01 I\/O module?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eIt provides an RJ-45 Ethernet connection and an RS232 serial interface.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eWhat protocols can run over the Ethernet connection?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eIt supports Modbus\/TCP protocol as well as the proprietary Bently Nevada host protocol for software applications.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eHow does this module differ from the older 3500\/90 module?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eIt removes the fixed primary value Modbus registers and replaces them with a flexible Configurable Modbus Register Utility.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eHow long does it take for the module to refresh data from the rack?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThe data collection rate varies by configuration but is guaranteed not to exceed 1 second for all modules.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eWhat is the typical power consumption of this specific I\/O setup?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThe system typically consumes 5.0 Watts when equipped with the Modbus RS232 I\/O module configuration.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eCan I connect my 3500 Configuration Software through this gateway?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eYes, it allows Ethernet communications with the 3500 Rack Configuration and Data Acquisition Software packages.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eWhat should I check if the TX\/RX LED is dark?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eVerify that the module is correctly seated and that the internal rack communication bus is active and functioning.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eIs a firmware upgrade mandatory when swapping in a new 136188-01 interface?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eOlder main gateway modules require a firmware upgrade using kit 126M4118-01 to properly recognize the new I\/O hardware.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eWhat are the environmental storage limitations for this hardware?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThe module must be stored within an environment ambient temperature range of -40 degC to +85 degC.\u003c\/p\u003e","brand":"Bently Nevada","offers":[{"title":"Default Title","offer_id":52666852540779,"sku":"3500\/92-03-01-00 136188-01","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/3227\/0443\/files\/bently-nevada-3500-92-03-01-00-136188-01-ethernet-rs232-modbusi-o-module-p13m3rotikn_8ccc5100-a46c-4dba-8a08-f4cf661d45b3.jpg?v=1765449087","url":"https:\/\/www.plcprotech.com\/products\/bently-nevada-3500-92-03-01-00-136188-01-ethernet-rs232-modbus-i-o-module","provider":"PLC ProTech Ltd.","version":"1.0","type":"link"}