{"product_id":"bently-nevada-3500-92-03-01-00-3500-series-communication-gateway-module","title":"Bently Nevada 3500\/92-03-01-00 3500 Series Communication Gateway Module","description":"\u003ch3\u003eDescription\u003c\/h3\u003e\n\u003cp\u003eSeamless machinery protection integration is achieved through the \u003cstrong\u003eBently Nevada 3500\/92-03-01-00\u003c\/strong\u003e, a high-performance communication gateway module designed for the 3500 Series machinery protection system. This module facilitates high-speed digital communication by exporting crucial rack data—including current values, monitor statuses, configuration information, and event lists—to external plant control networks.\u003c\/p\u003e\n\n\u003cp\u003eThe specific configuration of the \u003cstrong\u003e3500\/92-03-01-00\u003c\/strong\u003e includes an Ethernet and RS232 Modbus I\/O module, a low memory allocation framework, and no specific hazardous area agency approvals. Utilizing Modbus RTU and Modbus TCP\/IP protocols, this gateway ensures compatible connectivity with Distributed Control Systems (DCS), Programmable Logic Controllers (PLCs), Human-Machine Interfaces (HMIs), and plant historians, eliminating the need for complex custom drivers.\u003c\/p\u003e\n\n\u003ch3\u003eFeatures\u003c\/h3\u003e\n\u003cul\u003e\n  \u003cli\u003eProvides continuous, high-speed digital data transmission from 3500 racks to external control architectures.\u003c\/li\u003e\n  \u003cli\u003eSupports simultaneous Modbus RTU (serial) and Modbus TCP\/IP (ethernet) communication protocols.\u003c\/li\u003e\n  \u003cli\u003eEquipped with an Ethernet\/RS232 interface for versatile industrial system physical connectivity.\u003c\/li\u003e\n  \u003cli\u003eFront-panel OK LED status indicator provides rapid local diagnostic visual verification.\u003c\/li\u003e\n  \u003cli\u003eLow-memory architecture tailored for efficient, dedicated static and dynamic register mapping.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eApplications\u003c\/h3\u003e\n\u003cul\u003e\n  \u003cli\u003eReal-time data integration with industrial Distributed Control Systems (DCS).\u003c\/li\u003e\n  \u003cli\u003eTurbine, compressor, and rotating machinery condition monitoring loops.\u003c\/li\u003e\n  \u003cli\u003ePlant-wide asset management and predictive maintenance database synchronization.\u003c\/li\u003e\n  \u003cli\u003ePower generation, oil and gas processing, and chemical refining control systems.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eOrdering Information\u003c\/h3\u003e\n\u003ctable\u003e\n  \u003cthead\u003e\n    \u003ctr\u003e\n      \u003cth\u003eOption Code\u003c\/th\u003e\n      \u003cth\u003eSelection Definition\u003c\/th\u003e\n    \u003c\/tr\u003e\n  \u003c\/thead\u003e\n  \u003ctbody\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003e03\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003eEthernet\/RS232 Modbus I\/O Module\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003e01\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003eLow Memory Capacity\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003e00\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003eNo Agency Approvals Required\u003c\/td\u003e\n    \u003c\/tr\u003e\n  \u003c\/tbody\u003e\n\u003c\/table\u003e\n\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003ctable\u003e\n  \u003cthead\u003e\n    \u003ctr\u003e\n      \u003cth\u003eParameter\u003c\/th\u003e\n      \u003cth\u003eSpecification Value\u003c\/th\u003e\n    \u003c\/tr\u003e\n  \u003c\/thead\u003e\n  \u003ctbody\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eManufacturer\u003c\/td\u003e\n      \u003ctd\u003eBently Nevada\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003ePart Number \/ Model\u003c\/td\u003e\n      \u003ctd\u003e3500\/92-03-01-00\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eProduct Series\u003c\/td\u003e\n      \u003ctd\u003e3500 Machinery Protection System\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eModule Type\u003c\/td\u003e\n      \u003ctd\u003eCommunication Gateway\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eI\/O Module Option\u003c\/td\u003e\n      \u003ctd\u003eEthernet\/RS232 Modbus I\/O\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eMemory Configuration\u003c\/td\u003e\n      \u003ctd\u003eLow Memory\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eAgency Approvals\u003c\/td\u003e\n      \u003ctd\u003eNone (Option 00)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003ePower Consumption\u003c\/td\u003e\n      \u003ctd\u003e5.0 watts typical (with RS232\/RS422 I\/O), 5.6 watts typical (with RS485 I\/O)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eOperating Temperature\u003c\/td\u003e\n      \u003ctd\u003e-30 degC to +65 degC (-22 degF to +150 degF)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eStorage Temperature\u003c\/td\u003e\n      \u003ctd\u003e-40 degC to +85 degC (-40 degF to +185 degF)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eHumidity Constraints\u003c\/td\u003e\n      \u003ctd\u003e95% non-condensing relative humidity\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eShipping Weight\u003c\/td\u003e\n      \u003ctd\u003e2.5 kg\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eCountry of Origin\u003c\/td\u003e\n      \u003ctd\u003eUSA\u003c\/td\u003e\n    \u003c\/tr\u003e\n  \u003c\/tbody\u003e\n\u003c\/table\u003e\n\n\u003ch3\u003eConnections and Interfaces\u003c\/h3\u003e\n\u003ctable\u003e\n  \u003cthead\u003e\n    \u003ctr\u003e\n      \u003cth\u003eInterface Type\u003c\/th\u003e\n      \u003cth\u003ePhysical Connector \/ Protocol Specification\u003c\/th\u003e\n    \u003c\/tr\u003e\n  \u003c\/thead\u003e\n  \u003ctbody\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eEthernet Port\u003c\/td\u003e\n      \u003ctd\u003eRJ45 connector supporting Modbus TCP\/IP protocol over 10Base-T\/100Base-TX\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eSerial Interface\u003c\/td\u003e\n      \u003ctd\u003eRS232 physical serial connection using standard Modbus RTU framing\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eDiagnostic Indicator\u003c\/td\u003e\n      \u003ctd\u003eOK LED on front panel indicating active operating health status\u003c\/td\u003e\n    \u003c\/tr\u003e\n  \u003c\/tbody\u003e\n\u003c\/table\u003e\n\n\u003ch3\u003eInstallation Guidelines\u003c\/h3\u003e\n\u003cul\u003e\n  \u003cli\u003eAlways install the main 3500\/92 gateway module into a valid monitor slot in a standard 3500 rack.\u003c\/li\u003e\n  \u003cli\u003eEnsure the corresponding Ethernet\/RS232 I\/O module is firmly seated directly behind the main module in the rear of the rack chassis.\u003c\/li\u003e\n  \u003cli\u003eVerify all communication and power connections are secured prior to energizing the rack to prevent interface signal degradation.\u003c\/li\u003e\n  \u003cli\u003eAdhere to recommended signal wiring separation guidelines to isolate communication cables from high-voltage transient fields.\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Bently Nevada","offers":[{"title":"Default Title","offer_id":52668300788075,"sku":"3500\/92-03-01-00","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0953\/3227\/0443\/files\/350092-03-01-00-ynfarp3akob_a8471cfa-cab0-429c-b4f4-3c0c580cb104.jpg?v=1765520535","url":"https:\/\/www.plcprotech.com\/products\/bently-nevada-3500-92-03-01-00-3500-series-communication-gateway-module","provider":"PLC ProTech Ltd.","version":"1.0","type":"link"}